An Overview of Elastography-An Emerging Branch of Medical Imaging

被引:327
作者
Sarvazyan, Armen [1 ]
Hall, Timothy J. [2 ]
Urban, Matthew W. [3 ]
Fatemi, Mostafa [3 ]
Aglyamov, Salavat R. [4 ]
Garra, Brian S. [5 ,6 ]
机构
[1] Artann Labs, Trenton, NJ 08618 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[3] Mayo Clin, Coll Med, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[4] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78751 USA
[5] Washington DC Vet Affairs Med Ctr, Dept Radiol, Washington, DC 20422 USA
[6] FDA, CDRH, Div Imaging & Appl Math, Silver Spring, MD 20993 USA
关键词
Elasticity; viscoelasticity; stiffness; modulus; ultrasound; MRI; elastography; MRE; ACOUSTIC-RADIATION-FORCE; MAGNETIC-RESONANCE ELASTOGRAPHY; ENDOSCOPIC ULTRASOUND ELASTOGRAPHY; REAL-TIME ELASTOGRAPHY; ASSESSMENT POSTCARDIAC CATHETERIZATION; NONINVASIVE MATERIAL CHARACTERIZATION; POISSONS RATIO ELASTOGRAPHY; PROSTATE-CANCER DETECTION; SHEAR-WAVE PROPAGATION; IN-VIVO ASSESSMENT;
D O I
10.2174/157340511798038684
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
From times immemorial manual palpation served as a source of information on the state of soft tissues and allowed detection of various diseases accompanied by changes in tissue elasticity. During the last two decades, the ancient art of palpation gained new life due to numerous emerging elasticity imaging (EI) methods. Areas of applications of EI in medical diagnostics and treatment monitoring are steadily expanding. Elasticity imaging methods are emerging as commercial applications, a true testament to the progress and importance of the field. In this paper we present a brief history and theoretical basis of EI, describe various techniques of EI, analyze their advantages and limitations, and overview main clinical applications. We present a classification of elasticity measurement and imaging techniques based on the methods used for generating a stress in the tissue (external mechanical force, internal ultrasound radiation force, or an internal endogenous force), and measurement of the tissue response. The measurement method can be performed using differing physical principles including magnetic resonance imaging (MRI), ultrasound imaging, X-ray imaging, optical and acoustic signals. Until recently, EI was largely a research method used by a few select institutions having the special equipment needed to perform the studies. Since 2005 however, increasing numbers of mainstream manufacturers have added EI to their ultrasound systems so that today the majority of manufacturers offer some sort of Elastography or tissue stiffness imaging on their clinical systems. Now it is safe to say that some sort of elasticity imaging may be performed on virtually all types of focal and diffuse disease. Most of the new applications are still in the early stages of research, but a few are becoming common applications in clinical practice.
引用
收藏
页码:255 / 282
页数:28
相关论文
共 349 条
[1]   Strain rate Imaging for assessment of regional myocardial function - Results from a clinical model of septal ablation [J].
Abraham, TP ;
Nishimura, RA ;
Holmes, DR ;
Belohlavek, M ;
Seward, JB .
CIRCULATION, 2002, 105 (12) :1403-1406
[2]  
Aglyamov S, 2004, IEEE T ULTRASON FERR, V51, P521, DOI 10.1109/TUFFC.2004.1302761
[3]   Model-Based Reconstructive Elasticity Imaging Using Ultrasound [J].
Aglyamov, Salavat R. ;
Skovoroda, Andrei R. ;
Xie, Hua ;
Kim, Kang ;
Rubin, Jonathan M. ;
O'Donnell, Matthew ;
Wakefield, Thomas W. ;
Myers, Daniel ;
Emelianov, Stanislav Y. .
INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2007, 2007
[4]   An Inverse Problem Approach for Elasticity Imaging through Vibroacoustics [J].
Aguilo, Miguel A. ;
Aquino, Wilkins ;
Brigham, John C. ;
Fatemi, Mostafa .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (04) :1012-1021
[5]   Accuracy of sonographic elastography in the differential diagnosis of enlarged cervical lymph nodes: Comparison with conventional B-mode sonography [J].
Alam, Farzana ;
Naito, Kumiko ;
Horiguchi, Jun ;
Fukuda, Hiroshi ;
Tachikake, Toshihiro ;
Ito, Katsuhide .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (02) :604-610
[6]   Prostate cancer and the Will Rogers phenomenon [J].
Albertsen, PC ;
Hanley, JA ;
Barrows, GH ;
Penson, DF ;
Kowalczyk, PDH ;
Sanders, MM ;
Fine, J .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2005, 97 (17) :1248-1253
[7]   Potential applications of vibro-acoustography in breast imaging [J].
Alizad, A ;
Whaley, DH ;
Greenleaf, JF ;
Fatemi, M .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2005, 4 (02) :151-157
[8]   Performance of vibro-acoustography in detecting microcalcifications in excised human breast tissue: A study of 74 tissue samples [J].
Alizad, A ;
Fatemi, M ;
Wold, LE ;
Greenleaf, JF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (03) :307-312
[9]   Imaging mass lesions by vibro-acoustography: Modeling and experiments [J].
Alizad, A ;
Wold, LE ;
Greenleaf, JF ;
Fatemi, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (09) :1087-1093
[10]   Application of vibro-acoustography for detection of calcified arteries in breast tissue [J].
Alizad, A ;
Fatemi, M ;
Whaley, DH ;
Greenleaf, JF .
JOURNAL OF ULTRASOUND IN MEDICINE, 2004, 23 (02) :267-273