Comparison of the influence of curing times applied to composite resins cured with LED and incandescent light

被引:2
|
作者
Ulhoa, Michele P. M. [1 ]
Santana, Lucio R. S. [1 ]
Bianchi, Eduardo C. [1 ]
Cruz, Carlos E. D. [1 ]
Aguiar, Paulo R. [1 ]
de Freitas, Cesar A. [2 ]
de Freitas, Marcia F. A. [2 ]
机构
[1] UNESP, Univ Estadual Paulista, Fac Engn Bauru, Dept Engn Mecan, BR-17033360 Bauru, SP, Brazil
[2] Univ Sao Paulo, Fac Odontol Bauru, Sao Paulo, Brazil
来源
POLIMEROS-CIENCIA E TECNOLOGIA | 2007年 / 17卷 / 03期
关键词
composite resin; abrasive wear evaluation methods; microhardness;
D O I
10.1590/S0104-14282007000300017
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The purpose of this work was to compare polymeric dental resins cured with halogen lamp and with light emission diode (LED) devices, using the grinding disk method customized for dentistry and the corresponding microhardness values. Tests were carried out on resin samples of five brands, which were cured for 10, 20 and 40 s with the two devices. The analysis of microhardness and aggressiveness has allowed us to conclude that there is no correlation between these properties. In Microhardness tests, the material heterogeneity has produced relative hi h standard deviation values and has 4 9 not shown statistical differences between the analyzed samples. In the statistical analysis for the results with the Grinding disk method, the resin with highest wear was the Tetric Ceram, cured with LED device for 10 s (aggressiveness average 0.170 mm(3)/N.m). The composite resin with least wear was Charisma, cured with halogen lamp device for 20 s (aggressiveness average 0.057 mm(3)/N.m).
引用
收藏
页码:258 / 262
页数:5
相关论文
共 50 条
  • [21] Evaluation of Polymerization Shrinkage of Light Cured Composite Resins
    Damineni, Ravisankar
    Abhilash
    Shailendra, Mashalkar
    Reddy, G. Sharaschandra
    ADVANCES IN HUMAN BIOLOGY, 2014, 4 (03) : 26 - 30
  • [22] RADIOPACITY OF LIGHT-CURED POSTERIOR COMPOSITE RESINS
    STANFORD, CM
    FAN, PL
    SCHOENFELD, CM
    KNOEPPEL, R
    STANFORD, JW
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1987, 115 (05): : 722 - 724
  • [23] TENSILE-STRENGTH OF LIGHT CURED COMPOSITE RESINS
    FUJISHIMA, A
    MIYAZAKI, T
    MIYAJI, T
    JOURNAL OF DENTAL RESEARCH, 1988, 67 (04) : 730 - 730
  • [24] Shrinkage stress in light-cured composite resins: Influence of material and photoactivation mode
    Charton, Christophe
    Colon, Pierre
    Pla, Fernand
    DENTAL MATERIALS, 2007, 23 (08) : 911 - 920
  • [25] Determination of curing time in visible-light-cured composite resins of different thickness by electron paramagnetic resonance
    Sustercic, D
    Cevc, P
    Funduk, N
    Pintar, MM
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (08) : 507 - 510
  • [26] Determination of curing time in visible-light-cured composite resins of different thickness by electron paramagnetic resonance
    D SUSTERCIC
    P CEVC
    N FUNDUK
    M. M PINTAR
    Journal of Materials Science: Materials in Medicine, 1997, 8 : 507 - 510
  • [27] Determination of curing time in visible-light-cured composite resins of different thickness by electron paramagnetic resonance
    University Dental Clinic, Hrvatski trg 6, Ljubljana, Slovenia
    不详
    不详
    J. MATER. SCI. MATER. MED., 8 (507-510):
  • [28] Evaluation of polymerization contraction forces of composite resins using halogen and LED light curing units.
    Castañeda-Espinosa, JC
    Mondelli, RFL
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 129 - 129
  • [29] The applicability of DPSS laser for light curing of composite resins
    Kwon, Yong Hoon
    Jang, Chang-Min
    Shin, Dong-Hee
    Seol, Hyo-Joung
    Kim, Hyung-Il
    LASERS IN MEDICAL SCIENCE, 2008, 23 (04) : 407 - 414
  • [30] INDICATIONS FOR SELF-CURED AND LIGHT-CURED ADHESIVE COMPOSITE RESINS
    FUSAYAMA, T
    JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (01): : 46 - 51