Comparison of the sensitivities of 5 different computed tomography scanners for the assessment of the progression of pulmonary emphysema - A phantom study

被引:40
作者
Stoel, BC
Bakker, ME
Stolk, J
Dirksen, A
Stockley, RA
Piitulainen, E
Russi, EW
Reiber, JHC
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, Div Image Proc, NL-2333 ZA Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Pulmonol, NL-2333 ZA Leiden, Netherlands
[3] Gentofte Univ Hosp, Dept Resp Med, Hellerup, Denmark
[4] Queen Elizabeth Hosp, Dept Resp Med, Birmingham B15 2TH, W Midlands, England
[5] Malmo Univ Hosp, Dept Pulm Med, Malmo, Sweden
[6] Univ Zurich Hosp, Pulmonol Div, CH-8091 Zurich, Switzerland
关键词
emphysema; computed tomography; quantitative; lung densitometry;
D O I
10.1097/01.rli.0000091842.82062.a3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To compare the sensitivities of 5 different computed tomography scanners (4 multislice CT [MSCT] and 1 single-slice CT) in the assessment of the progression of pulmonary emphysema. Methods: A Perspex cylinder phantom was constructed containing small pieces of polythene foam with densities representative of lung. Changing the cylinder's volume simulated subtle lung density changes. The sensitivity to density changes was defined by the variation in the residual errors from the linear regression line between time and density. Results: The single-slice CT scanner was significantly less sensitive to density changes than MSCT scanners. Also, among MSCT scanners, small but significant differences were found when the standardized acquisition protocol was used. Conclusions: Considering the large sensitivity differences between single- and multislice CT scanners, we would recommended using MSCT scanners in clinical multicenter trials in emphysema. The protocol standardization of MSCT scanners can still be further improved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 13 条
[1]   Pulmonary emphysema: Subjective visual grading versus objective quantification with macroscopic morphometry and thin-section CT densitometry [J].
Bankier, AA ;
De Maertelaer, V ;
Keyzer, C ;
Gevenois, PA .
RADIOLOGY, 1999, 211 (03) :851-858
[2]   A randomized clinical trial of α1-antitrypsin augmentation therapy [J].
Dirksen, A ;
Dijkman, JH ;
Madsen, F ;
Stoel, B ;
Hutchison, DCS ;
Ulrik, CS ;
Skovgaard, LT ;
Kok-Jensen, A ;
Rudolphus, A ;
Seersholm, N ;
Vrooman, HA ;
Reiber, JHC ;
Hansen, NC ;
Heckscher, T ;
Viskum, K ;
Stolk, J .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (05) :1468-1472
[3]   Longitudinal changes in physiological, radiological, and health status measurements in α1-antitrypsin deficiency and factors associated with decline [J].
Dowson, LJ ;
Guest, PJ ;
Stockley, RA .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (10) :1805-1809
[4]   COMPUTED-TOMOGRAPHY IN PULMONARY-EMPHYSEMA [J].
GODDARD, PR ;
NICHOLSON, EM ;
LASZLO, G ;
WATT, I .
CLINICAL RADIOLOGY, 1982, 33 (04) :379-387
[5]  
GOULD GA, 1993, EUR RESPIR J, V6, P698
[6]   MEASUREMENT OF LUNG DENSITY BY MEANS OF QUANTITATIVE CT SCANNING - A STUDY OF CORRELATIONS WITH PULMONARY-FUNCTION TESTS [J].
HEREMANS, A ;
VERSCHAKELEN, JA ;
VANFRAEYENHOVEN, L ;
DEMEDTS, M .
CHEST, 1992, 102 (03) :805-811
[7]   CT lung densitometry: Dependence of CT number histograms on sample volume and consequences for scan protocol comparability [J].
Kemerink, GJ ;
Kruize, HH ;
Lamers, RJS ;
vanEngelshoven, JMA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (06) :948-954
[8]   Density resolution in quantitative computed tomography of foam and lung [J].
Kemerink, GJ ;
Kruize, HH ;
Lamers, RJS ;
vanEngelshoven, JMA .
MEDICAL PHYSICS, 1996, 23 (10) :1697-1708
[9]   QUANTITATION OF EMPHYSEMA BY COMPUTED-TOMOGRAPHY USING A DENSITY MASK PROGRAM AND CORRELATION WITH PULMONARY-FUNCTION TESTS [J].
KINSELLA, M ;
MULLER, NL ;
ABBOUD, RT ;
MORRISON, NJ ;
DYBUNCIO, A .
CHEST, 1990, 97 (02) :315-321
[10]   Sources of error in lung densitometry with CT [J].
Stoel, BC ;
Vrooman, HA ;
Stolk, J ;
Reiber, JHC .
INVESTIGATIVE RADIOLOGY, 1999, 34 (04) :303-309