Sleep-Wake Evaluation from Whole-Night Non-Contact Audio Recordings of Breathing Sounds

被引:39
作者
Dafna, Eliran [1 ]
Tarasiuk, Ariel [2 ,3 ]
Zigel, Yaniv [1 ]
机构
[1] Ben Gurion Univ Negev, Fac Engn, Dept Biomed Engn, IL-84105 Beer Sheva, Israel
[2] Ben Gurion Univ Negev, Soroka Univ Med Ctr, Sleep Wake Disorders Unit, IL-84105 Beer Sheva, Israel
[3] Ben Gurion Univ Negev, Fac Hlth Sci, Dept Physiol, IL-84105 Beer Sheva, Israel
关键词
WRIST ACTIGRAPHY; APNEA; VALIDATION; MOVEMENT; RESPIRATION; ADOLESCENTS; DIAGNOSIS; PATTERNS; DEVICE; ONSET;
D O I
10.1371/journal.pone.0117382
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Study Objectives To develop and validate a novel non-contact system for whole-night sleep evaluation using breathing sounds analysis (BSA). Design Whole-night breathing sounds (using ambient microphone) and polysomnography (PSG) were simultaneously collected at a sleep laboratory (mean recording time 7.1 hours). A set of acoustic features quantifying breathing pattern were developed to distinguish between sleep and wake epochs (30 sec segments). Epochs (n = 59,108 design study and n = 68,560 validation study) were classified using AdaBoost classifier and validated epoch-by-epoch for sensitivity, specificity, positive and negative predictive values, accuracy, and Cohen's kappa. Sleep quality parameters were calculated based on the sleep/wake classifications and compared with PSG for validity. Setting University affiliated sleep-wake disorder center and biomedical signal processing laboratory. Patients One hundred and fifty patients (age 54.0 +/- 14.8 years, BMI 31.6 +/- 5.5 kg/m(2), m/f97/53) referred for PSG were prospectively and consecutively recruited. The system was trained (design study) on 80 subjects; validation study was blindly performed on the additional 70 subjects. Measurements and Results Epoch-by-epoch accuracy rate for the validation study was 83.3% with sensitivity of 92.2% (sleep as sleep), specificity of 56.6% (awake as awake), and Cohen's kappa of 0.508. Comparing sleep quality parameters of BSA and PSG demonstrate average error of sleep latency, total sleep time, wake after sleep onset, and sleep efficiency of 16.6 min, 35.8 min, and 29.6 min, and 8%, respectively. Conclusions This study provides evidence that sleep-wake activity and sleep quality parameters can be reliably estimated solely using breathing sound analysis. This study highlights the potential of this innovative approach to measure sleep in research and clinical circumstances.
引用
收藏
页数:22
相关论文
共 52 条
[1]   Estimating sleep patterns with activity monitoring in children and adolescents: How many nights are necessary for reliable measures? [J].
Acebo, C ;
Sadeh, A ;
Seifer, R ;
Tzischinsky, O ;
Wolfson, AR ;
Hafer, A ;
Carskadon, MA .
SLEEP, 1999, 22 (01) :95-103
[2]  
Akhter S, 2013, IEEE ENG MED BIO, P1318, DOI 10.1109/EMBC.2013.6609751
[3]   The role of actigraphy in the study of sleep and circadian rhythms [J].
Ancoli-Israel, S ;
Cole, R ;
Alessi, C ;
Chambers, M ;
Moorcroft, W ;
Pollak, CP .
SLEEP, 2003, 26 (03) :342-392
[4]  
Appelboom G, 2014, ARCH PUBLIC HEALTH, V72, DOI 10.1186/2049-3258-72-28
[5]   Obstructive Apnea Hypopnea Index Estimation by Analysis of Nocturnal Snoring Signals in Adults [J].
Ben-Israel, Nir ;
Tarasiuk, Ariel ;
Zigel, Yaniv .
SLEEP, 2012, 35 (09) :1299-1305
[6]   Automatic analysis of single-channel sleep EEG:: Validation in healthy individuals [J].
Berthomier, Christian ;
Drouot, Xavier ;
Herman-Stoieca, Maria ;
Berthomier, Pierre ;
Prado, Jacques ;
Bokar-Thire, Djibril ;
Benoit, Odile ;
Mattout, Jeremie ;
d'Ortho, Marie-Pia .
SLEEP, 2007, 30 (11) :1587-1595
[7]   Comparison of sleep parameters from actigraphy and polysomnography in older women: The SOF study [J].
Blackwell, Terri ;
Redline, Susan ;
Ancoli-Israel, Sonia ;
Schneider, Jennifer L. ;
Surovec, Susan ;
Johnson, Nathan L. ;
Cauley, Jane A. ;
Stone, Katie L. .
SLEEP, 2008, 31 (02) :283-291
[8]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[9]   Validation study of portable device for the diagnosis of obstructive sleep apnea according to the new AASM scoring criteria: Watch-PAT 100 [J].
Choi, Ji Ho ;
Kim, Eun Joong ;
Kim, Yang Soo ;
Choi, June ;
Kim, Tae Hoon ;
Kwon, Soon Young ;
Lee, Heung Man ;
Lee, Sang Hag ;
Shin, Chol ;
Lee, Seung Hoon .
ACTA OTO-LARYNGOLOGICA, 2010, 130 (07) :838-843
[10]  
Collop NA, 2007, J CLIN SLEEP MED, V3, P737