Diagnostic accuracy of handheld cardiac ultrasound device for assessment of left ventricular structure and function: systematic review and meta-analysis

被引:23
作者
Jenkins, Sam [1 ]
Alabed, Samer [1 ]
Swift, Andrew [2 ]
Marques, Gabriel [3 ]
Ryding, Alisdair [3 ]
Sawh, Chris [3 ]
Wardley, James [3 ]
Shah, Benoy Nalin [4 ]
Swoboda, Peter [5 ]
Senior, Roxy [6 ]
Nijveldt, Robin [7 ]
Vassiliou, Vassilios S. [8 ]
Garg, Pankaj [3 ]
机构
[1] Univ Sheffield, Dept Infect Immun & Cardiovasc Dis, Sheffield, S Yorkshire, England
[2] Univ Sheffield, Acad Unit Radiol, Cardiovasc & Metab Hlth, Sheffield, S Yorkshire, England
[3] Norfolk & Norwich Univ Hosp NHS Trust, Cardiol, Norwich NR4 7UQ, Norfolk, England
[4] Univ Hosp Southampton, Wessex Cardiothorac Ctr, Cardiol, Southampton, Hants, England
[5] Univ Leeds, LICAMM, Leeds, W Yorkshire, England
[6] Royal Brompton Hosp, Dept Cardiol, London, England
[7] Vrije Univ Amsterdam, Amsterdam, Netherlands
[8] Univ East Anglia, Norwich Med Sch, Second Floor, Norwich, Norfolk, England
基金
英国惠康基金;
关键词
echocardiography; diagnostic imaging; cardiac imaging techniques; meta-analysis; CARRIED ULTRASOUND; PHYSICAL-EXAMINATION; SYSTOLIC DYSFUNCTION; ECHOCARDIOGRAPHY; STANDARD; FEASIBILITY; ULTRASONOGRAPHY; RELIABILITY; HOSPITALISTS; CAPABILITY;
D O I
10.1136/heartjnl-2021-319561
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective Handheld ultrasound devices (HUD) has diagnostic value in the assessment of patients with suspected left ventricular (LV) dysfunction. This meta-analysis evaluates the diagnostic ability of HUD compared with transthoracic echocardiography (TTE) and assesses the importance of operator experience. Methods MEDLINE and EMBASE databases were searched in October 2020. Diagnostic studies using HUD and TTE imaging to determine LV dysfunction were included. Pooled sensitivities and specificities, and summary receiver operating characteristic curves were used to determine the diagnostic ability of HUD and evaluate the impact of operator experience on test accuracy. Results Thirty-three studies with 6062 participants were included in the meta-analysis. Experienced operators could predict reduced LV ejection fraction (LVEF), wall motion abnormality (WMA), LV dilatation and LV hypertrophy with pooled sensitivities of 88%, 85%, 89% and 85%, respectively, and pooled specificities of 96%, 95%, 98% and 91%, respectively. Non-experienced operators are able to detect cardiac abnormalities with reasonable sensitivity and specificity. There was a significant difference in the diagnostic accuracy between experienced and inexperienced users in LV dilatation, LVEF (moderate/severe) and WMA. The diagnostic OR for LVEF (moderate/severe), LV dilatation and WMA in an experienced hand was 276 (95% CI 58 to 1320), 225 (95% CI 87 to 578) and 90 (95% CI 31 to 265), respectively, compared with 41 (95% CI 18 to 94), 45 (95% CI 16 to 123) and 28 (95% CI 20 to 41), respectively, for inexperienced users. Conclusion This meta-analysis is the first to establish HUD as a powerful modality for predicting LV size and function. Experienced operators are able to accurately diagnose cardiac disease using HUD. A cautious, supervised approach should be implemented when imaging is performed by inexperienced users. This study provides a strong rationale for considering HUD as an auxiliary tool to physical examination in secondary care, to aid clinical decision making when considering referral for TTE.
引用
收藏
页码:1826 / 1834
页数:9
相关论文
共 47 条
[1]   Accuracy of left ventricular ejection fraction determined by automated analysis of handheld echocardiograms: A comparison of experienced and novice examiners [J].
Aldaas, Omar M. ;
Igata, Sachiyo ;
Raisinghani, Ajit ;
Kraushaar, Megan ;
DeMaria, Anthony N. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (12) :2145-2151
[2]   Feasibility of point-of-care echocardiography by internal medicine house staff [J].
Alexander, JH ;
Peterson, ED ;
Chen, AY ;
Harding, TM ;
Adams, DB ;
Kisslo, JA .
AMERICAN HEART JOURNAL, 2004, 147 (03) :476-+
[3]   Feasibility and reliability of point-of-care pocket-sized echocardiography [J].
Andersen, Garrett Newton ;
Haugen, Bjorn Olav ;
Graven, Torbjorn ;
Salvesen, Oyvind ;
Mjolstad, Ole Christian ;
Dalen, Havard .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (09) :665-670
[4]   Mobile technology and the digitization of healthcare [J].
Bhavnani, Sanjeev P. ;
Narula, Jagat ;
Sengupta, Partho P. .
EUROPEAN HEART JOURNAL, 2016, 37 (18) :1428-1438A
[5]   Evaluation of a new pocket echoscopic device for focused cardiac ultrasonography in an emergency setting [J].
Biais, Matthieu ;
Carrie, Cedric ;
Delaunay, Francois ;
Morel, Nicolas ;
Revel, Philippe ;
Janvier, Gerard .
CRITICAL CARE, 2012, 16 (03)
[6]   Robot-Assisted Remote Echocardiographic Examination and Teleconsultation A Randomized Comparison of Time to Diagnosis With Standard of Care Referral Approach [J].
Boman, Kurt ;
Olofsson, Mona ;
Berggren, Peter ;
Sengupta, Partho P. ;
Narula, Jagat .
JACC-CARDIOVASCULAR IMAGING, 2014, 7 (08) :799-803
[7]   Utility of hand-carried ultrasound devices used by cardiologists with and without significant echocardiographic experience in the cardiology inpatient and outpatient settings [J].
Bruce, CJ ;
Montgomery, SC ;
Bailey, KR ;
Tajik, J .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (11) :1273-+
[8]   Reliability of cardiac dimensions and valvular regurgitation assessment by sonographers using hand-carried ultrasound devices [J].
Coletta, Claudio ;
De Marchis, Elettra ;
Lenoli, Monica ;
Rosato, Stefano ;
Renzi, Marco ;
Sestili, Augusto ;
Romano, Patrizia ;
Infusino, Tommaso ;
Ricci, Roberto ;
Ceci, Vincenzo .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2006, 7 (04) :275-283
[9]   Diagnostic Capability of Comprehensive Handheld vs Transthoracic Echocardiography [J].
Cullen, Michael W. ;
Blauwet, Lori A. ;
Vatury, Ori M. ;
Mulvagh, Sharon L. ;
Behrenbeck, Thomas R. ;
Scott, Christopher G. ;
Pellikka, Patricia A. .
MAYO CLINIC PROCEEDINGS, 2014, 89 (06) :790-798
[10]  
DeCara J M, 2003, Eur J Echocardiogr, V4, P141, DOI 10.1053/euje.2002.0617