Development and validation of an analytical method for hydrocarbon residues using gas chromatography-mass spectrometry

被引:9
作者
Choodum, Aree [1 ,2 ,3 ]
Daeid, Niamh Nic [1 ]
机构
[1] Univ Strathclyde, Royal Coll, Dept Pure & Appl Chem, Ctr Forens Sci,WestCHEM, Glasgow G1 1XW, Lanark, Scotland
[2] Prince Songkla Univ, Fac Sci, Dept Pure & Appl Sci, Hat Yai 90112, Thailand
[3] Prince Songkla Univ, Trace Anal & Biosensor Res Ctr, Hat Yai 90112, Thailand
关键词
AUTOMOTIVE GASOLINE SAMPLES; CARBON-DISULFIDE;
D O I
10.1039/c0ay00702a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work outlines the development of a gas chromatographic mass spectrometric (GCMS) method for the analysis of hydrocarbon residues such as those encountered in the examination of fire debris. The work compares favourably against an existing ASTM E-1618-06 method for ignitable liquid analysis currently used for the development of the National Centre for Forensic Science (NCFS) ignitable liquid database. A test mixture comprising fourteen hydrocarbons as recommended by the ASTM-1618-06 method was used to evaluate and validate the separation conditions together with a matrix matched ignitable liquid mixture diluted to 2 mu L mL(-1) in dichloromethane. Optimised conditions were as follows: injection volume of 1 mu L with split ratio 50 to 1 at inlet temperature 280 degrees C, carrier gas flow rate was set as 1.0 mL min(-1), the column temperature was maintained at 40 degrees C for 3 minutes, then increased at a rate of 12.5 degrees C min(-1) to 290 degrees C, and held for 4 minutes. Undiluted ignitable liquid samples (50% gasoline : diesel) were also analysed with a high split ratio (300 : 1) and low injection volume (0.2 mu L) to avoid column overloading and to eliminate any difficulties associated with solvent masking. This method provided improved separation and sensitivity compared to the ASTM method. Excellent precision both intra-day and inter-day (<3% RSD for peak area) was also obtained. The stability of ignitable liquid storage was also investigated over a two week period for various types of vials and septa.
引用
收藏
页码:1136 / 1142
页数:7
相关论文
共 20 条
  • [1] ALLEN SP, 2000, FORENSIC SCI COM JAN
  • [2] ALLEN SP, 2006, FORENSIC SCI COMMUN, V8
  • [3] Characterization of background and pyrolysis products that may interfere with the forensic analysis of fire debris
    Almirall, JR
    Furton, KG
    [J]. JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 2004, 71 (01) : 51 - 67
  • [4] ASTM, 2006, E161806 ASTM INT
  • [5] A CRITICAL-REVIEW OF THE LITERATURE ON CARBON-DISULFIDE TOXICITY
    BEAUCHAMP, RO
    BUS, JS
    POPP, JA
    BOREIKO, CJ
    GOLDBERG, L
    [J]. CRC CRITICAL REVIEWS IN TOXICOLOGY, 1983, 11 (03): : 169 - 278
  • [6] Is dichloromethane a useful alternative to CS2 in the extraction of organics sampled with activated charcoal adsorbents?
    Bertoni, G.
    Ciuchini, C.
    [J]. CHROMATOGRAPHIA, 2007, 66 (3-4) : 277 - 281
  • [7] Blumberg LM., 2010, Temperature-programmed gas chromatography
  • [8] A comparison of results obtained using liquid injection and headspace solid-phase microextraction for crude oil analysis by GC with mass spectrometer detection
    D'Auria, Maurizio
    Racioppi, Rocco
    Velluzzi, Vincenzina
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (04) : 332 - 338
  • [9] Gasoline on. hands:: Preliminary study on collection and persistence
    Darrer, Melinda
    Jacquemet-Papilloud, Joelle
    Delemont, Olivier
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2008, 175 (2-3) : 171 - 178
  • [10] Application of Unsupervised Chemometric Analysis and Self-organizing Feature Map (SOFM) for the Classification of Lighter Fuels
    Desa, Wan N. S. Mat
    Daeid, Niamh Nic
    Ismail, Dzulkiflee
    Savage, Kathleen
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (15) : 6395 - 6400