A New Method for Blocking Third-Zone Distance Relays During Stable Power Swings

被引:50
|
作者
Kang, Don [1 ]
Gokaraju, Ramakrishna [1 ]
机构
[1] Univ Saskatchewan, Elect & Comp Engn Dept, Saskatoon, SK S7N 5A9, Canada
关键词
Distance relay; outages; power-swing identification; relay algorithm; third-zone blocking;
D O I
10.1109/TPWRD.2016.2520394
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The improper operation of the third-zone distance protection has been attributed as one of the factors for power system blackouts. The third-zone protection could incorrectly operate during power-swing scenarios. This research proposes a fast and practical methodology using local measurements for blocking the third-zone distance relays during stable power swings. The proposed scheme is referred to as the BTZ scheme. The proposed method calculates the relative speed of a fictitious equivalent machine from the local relay measurements. If the relative speed goes through a zero crossing, the swing is classified as a stable power swing; whereas if the speed does not go through a zero value, then the swing is classified as an unstable power swing. The benefit of the proposed method is that it analyzes the power swings from a system stability point of view, and does not need rigorous offline simulation studies to determine the relay settings. The performance of the proposed method in this paper is compared with an industry-standard method (conventional double blinder method). As is well known, the settings of the blinder-based methods are system specific and need several simulations to arrive at the blinder values. Transient simulation studies on a three-bus system and a modified Western Coordination Council 9-bus system are used to test the performance of the proposed approach.
引用
收藏
页码:1836 / 1843
页数:8
相关论文
共 50 条
  • [1] A New Method for Blocking Third Zone Distance Relays during Stable Power Swings
    Kang, Don
    Gokaraju, Ramakrishna
    2017 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2017,
  • [2] A new method for improving the fault detection performance of distance relays during power swings
    Li, Mei
    Sun, Chao
    Wu, Zailin
    Gong, Xiaolong
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 224
  • [3] A New Blocking Scheme for Distance Protection during Power Swings
    Abidin, Ahmad Farid
    Mohamed, Azah
    Shareef, Hussain
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2010, 11 (01):
  • [4] Detection of Symmetrical Faults by Distance Relays During Power Swings
    Lotfifard, Saeed
    Faiz, Jawad
    Kezunovic, Mladen
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (01) : 81 - 87
  • [5] Performance of protection relays during stable and unstable power swings
    McGuinness, Sean
    Patel, Mahendra
    Kelly, Adrian
    JOURNAL OF ENGINEERING-JOE, 2018, (15): : 1125 - 1129
  • [6] Adaptive Third-Zone Distance Protection Scheme for Power System Critical Conditions
    Venkatanagaraju, Kasimala
    Biswal, Monalisa
    Malik, Om Parkash
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (03) : 1401 - 1410
  • [7] Blocking the Distance Relay Operation in Third Zone during Power Swing Using Polynomial Curve Fitting Method
    Sriram, Cholleti
    Kumar, D. Ravi
    Raju, G. S.
    2014 INTERNATIONAL CONFERENCE ON SMART ELECTRIC GRID (ISEG), 2014,
  • [8] Operation condition for zone 3 impedance relays during low frequency power swings
    Hefei University of Technology, Hefei 230009, China
    Dianli Xitong Zidonghue, 2007, 20 (12-16):
  • [10] Power swing detection and blocking of the third zone of distance relays by the combined use of empirical-mode decomposition and Hilbert transform
    Taheri, Behrooz
    Hosseini, Seyed Amir
    Askarian-Abyaneh, Hossein
    Razavi, Farzad
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (06) : 1062 - 1076