Misfit detection in implant-supported prostheses of different compositions by periapical radiography and cone beam computed tomography: An in vitro study

被引:6
作者
De-Azevedo-Vaz, Sergio Lins [1 ]
Araujo-Siqueira, Caique [1 ]
Carneiro, Vinicius Cavalcanti [1 ]
Oliveira, Matheus Lima [2 ]
Azeredo, Rogerio Albuquerque [3 ]
机构
[1] Fed Univ Espirito Santo UFES, Dept Clin Dent, Vitoria, ES, Brazil
[2] Univ Campinas FOP UNICAMP, Piracicaba Dent Sch, Dept Oral Diag, Div Oral Radiol, Sao Paulo, Brazil
[3] Fed Univ Espirito Santo UFES, Dept Morphol, Vitoria, ES, Brazil
关键词
VERTICAL MISFIT; ARTIFACTS; CBCT; DENTISTRY; TITANIUM; DENSITY; IMPACT; CARIES; FIELD; SIZE;
D O I
10.1016/j.prosdent.2020.04.020
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Misfits at the implant-abutment joint (IAJ) can cause the biological and mechanical failure of implant therapy. Standard parallel periapical radiography (PERI) is the method of choice for assessing the fitting of implant-supported prostheses. Although current guidelines do not support the use of cone beam computed tomography (CBCT) solely for misfit detection, CBCT scans can also register misfits as imaging findings. Whether the material used for prostheses manufacturing influences misfit appearance in PERI and CBCT images is unknown. Purpose. The purpose of this in vitro study was to assess the influence of the type of prosthesis material on misfit detection at the IAJ by using PERI and CBCT. Material and methods. Thirty-two implants with an external hexagon connection were placed in dried human mandibles. Implant-supported crowns were manufactured with different materials and allocated to 3 experimental groups: metal-ceramic (MC), titanium abutment veneered with acrylic resin (TIT), and zirconia abutment veneered with glass-ceramic (ZIR). All crowns were installed both with and without a simulated 200-mu m-thick gap at the IAJ (n=64) and were assessed by PERI and CBCT scans. Four dentists evaluated the images for the presence or absence of misfit. Statistical analysis included the Kappa test and areas under the receiver operating characteristics curve (Az values) comparisons (alpha=.05). Results. Kappa values indicated almost perfect intraevaluator and interevaluator reproducibility for PERI and ranged from fair to almost perfect for CBCT. For PERI, Az values were not significantly different among the MC (0.995), TIT (0.997), and ZIR groups (1.000) (P>.05). Regarding CBCT, the Az values found for TIT (0.941) and MC (0.890) were significantly higher than for ZIR (0.762) (P<.05). Az values for PERI were significantly higher than for CBCT (P<.05). Conclusions. The type of prosthesis material did not influence misfit detection at the IAJ with PERI; however, ZIR had lower diagnostic accuracy than TIT and MC implant-supported crowns with CBCT.
引用
收藏
页码:205 / 213
页数:9
相关论文
共 34 条
[1]   Effect of vertical misfit on strain within screw-retained implant titanium and zirconia frameworks [J].
Abduo, Jaafar ;
Lyons, Karl .
JOURNAL OF PROSTHODONTIC RESEARCH, 2012, 56 (02) :102-109
[2]  
Al-Turki LEE, 2002, INT J PROSTHODONT, V15, P38
[3]  
Aparicio C., 1994, INT J PERIODONT REST, V14, P405
[4]   Effect of framework material and vertical misfit on stress distribution in implant-supported partial prosthesis under load application: 3-D finite element analysis [J].
Bacchi, Atais ;
Xediek Consani, Rafael Leonardo ;
Mesquita, Marcelo Ferraz ;
Fernandes dos Santos, Mateus Bertolini .
ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (05) :1243-1249
[5]   The impact of digital image processing artefacts mimicking pathological features associated with restorations [J].
Brettle, D. ;
Carmichael, F. .
BRITISH DENTAL JOURNAL, 2011, 211 (04) :167-170
[6]   Peri-implant inflammation defined by the implant-abutment interface [J].
Broggini, N ;
McManus, LM ;
Hermann, JS ;
Medina, R ;
Schenk, RK ;
Buser, D ;
Cochran, DL .
JOURNAL OF DENTAL RESEARCH, 2006, 85 (05) :473-478
[7]   Accuracy of Digital Versus Conventional Periapical Radiographs to Detect Misfit at the Implant-Abutment Interface [J].
Cancado Oliveira, Bruno Fernando ;
Valerio, Claudia Scigliano ;
Jansen, Wellington Correa ;
Zenobio, Elton Goncalves ;
Manzi, Flavio Ricardo .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (05) :1023-1029
[8]   Metallic materials in the exomass impair cone beam CT voxel values [J].
Candemil, Amanda P. ;
Salmon, Benjamin ;
Freitas, Deborah Q. ;
Ambrosano, Glaucia M. B. ;
Haiter-Neto, Francisco ;
Oliveira, Matheus L. .
DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (06)
[9]   Microbiological assessment of the implant-abutment interface in different connections: cross-sectional study after 5 years of functional loading [J].
Canullo, Luigi ;
Penarrocha-Oltra, David ;
Soldini, Claudio ;
Mazzocco, Fabio ;
Penarrocha, Maria ;
Covani, Ugo .
CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (04) :426-434
[10]   Accuracy of Three Cone Beam Computed Tomography Systems in the Detection of Implant-Abutment Misfit [J].
Carneiro, Vinicius C. ;
Siqueira, Caique A. ;
Valentim, Flavia B. ;
Oliveira, Amanda L. E. ;
Oliveira, Matheus L. ;
Azeredo, Rogerio A. ;
de-Azevedo-Vaz, Sergio L. .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (02) :198-200