The PTW microSilicon diode: Performance in small 6 and 15 MV photon fields and utility of density compensation

被引:6
作者
Georgiou, Georgios [1 ,2 ,3 ,7 ]
Kumar, Sudhir [4 ]
Wuerfel, Jan U. [5 ]
Gilmore, Martyn [2 ]
Underwood, Tracy S. A. [6 ]
Rowbottom, Carl G. [2 ,3 ]
Fenwick, John D. [1 ,2 ]
机构
[1] Univ Liverpool, Inst Syst Mol & Integrat Biol, Dept Mol & Clin Canc Med, Sherrington Bldg,Ashton St, Liverpool L69 3BX, Merseyside, England
[2] Clatterbridge Canc Ctr, Dept Phys, Wirral, Merseyside, England
[3] Univ Liverpool, Dept Phys, Oliver Lodge Lab, Liverpool, Merseyside, England
[4] Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Mumbai, Maharashtra, India
[5] PTW Freiburg, Freiburg, Germany
[6] Univ Manchester, Fac Biol Med & Hlth, Sch Med Sci, Div Canc Sci, Manchester, Lancs, England
[7] Glan Clwyd Gen Hosp, North Wales Canc Treatment Ctr, Radiotherapy Phys Dept, Bodelwyddan LL18 5UJ, Wales
关键词
density compensation; diode; dose-rate; microSilicon; small field;
D O I
10.1002/mp.15329
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose We have experimentally and computationally characterized the PTW microSilicon 60023-type diode's performance in 6 and 15 MV photon fields >= 5 x 5 mm(2) projected to isocenter. We tested the detector on- and off-axis at 5 and 15 cm depths in water, and investigated whether its response could be improved by including within it a thin airgap. Methods Experimentally, detector readings were taken in fields generated by a Varian TrueBeam linac and compared with doses-to-water measured using Gafchromic film and ionization chambers. An unmodified 60023-type diode was tested along with detectors modified to include 0.6, 0.8, and 1.0 mm thick airgaps. Computationally, doses absorbed by water and detectors' sensitive volumes were calculated using the EGSnrc/BEAMnrc Monte Carlo radiation transport code. Detector response was characterized using kQclin,4cmfclin,4cm, a factor that corrects for differences in the ratio of dose-to-water to detector reading between small fields and the reference condition, in this study 5 cm deep on-axis in a 4 x 4 cm(2) field. Results The greatest errors in measurements of small field doses made using uncorrected readings from the unmodified 60023-type detector were over-responses of 2.6% +/- 0.5% and 5.3% +/- 2.0% determined computationally and experimentally, relative to the reading-per-dose in the reference field. Corresponding largest errors for the earlier 60017-type detector were 11.9% +/- 0.6% and 11.7% +/- 1.4% over-responses. Adding even the thinnest, 0.6 mm, airgap to the 60023-type detector over-corrected it, leading to under-responses of up to 4.8% +/- 0.6% and 5.0% +/- 1.8% determined computationally and experimentally. Further, Monte Carlo calculations indicate that a detector with a 0.3 mm airgap would read correctly to within 1.3% on-axis. The ratio of doses at 15 and 5 cm depths in water in a 6 MV 4 x 4 cm(2) field was measured more accurately using the unmodified 60023-type detector than using the 60017-type detector, and was within 0.3% of the ratio measured using an ion chamber. The 60023-type diode's sensitivity also varied negligibly as dose-rate was reduced from 13 to 4 Gy min(-1) by decreasing the linac pulse repetition frequency, whereas the sensitivity of the 60017-type detector fell by 1.5%. Conclusions The 60023-type detector performed well in small fields across a wide range of beam energies, field sizes, depths, and off-axis positions. Its response can potentially be further improved by adding a thin, 0.3 mm, airgap.
引用
收藏
页码:8062 / 8074
页数:13
相关论文
共 26 条
[1]   Characterization of a microSilicon diode detector for small-field photon beam dosimetry [J].
Akino, Yuichi ;
Fujiwara, Masateru ;
Okamura, Keita ;
Shiomi, Hiroya ;
Mizuno, Hirokazu ;
Isohashi, Fumiaki ;
Suzuki, Osamu ;
Seo, Yuji ;
Tamari, Keisuke ;
Ogawa, Kazuhiko .
JOURNAL OF RADIATION RESEARCH, 2020, 61 (03) :410-418
[2]   A new formalism for reference dosimetry of small and nonstandard fields [J].
Alfonso, R. ;
Andreo, P. ;
Capote, R. ;
Huq, M. Saiful ;
Kilby, W. ;
Kjaell, P. ;
Mackie, T. R. ;
Palmans, H. ;
Rosser, K. ;
Seuntjens, J. ;
Ullrich, W. ;
Vatnitsky, S. .
MEDICAL PHYSICS, 2008, 35 (11) :5179-5186
[3]  
Alfonso R., 2017, Technical Report Series.
[4]   Functional forms for photon spectra of clinical linacs [J].
Ali, E. S. M. ;
Rogers, D. W. O. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (01) :31-50
[5]  
[Anonymous], 2017, PIRS702 NAT RES COUN
[6]   Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife® and linear accelerators equipped with microMLC and circular cones [J].
Bassinet, C. ;
Huet, C. ;
Derreumaux, S. ;
Brunet, G. ;
Chea, M. ;
Baumann, M. ;
Lacornerie, T. ;
Gaudaire-Josset, S. ;
Trompier, F. ;
Roch, P. ;
Boisserie, G. ;
Clairand, I. .
MEDICAL PHYSICS, 2013, 40 (07)
[7]   Design and experimental testing of air slab caps which convert commercial electron diodes into dual purpose, correction-free diodes for small field dosimetry [J].
Charles, P. H. ;
Cranmer-Sargison, G. ;
Thwaites, D. I. ;
Kairn, T. ;
Crowe, S. B. ;
Pedrazzini, G. ;
Aland, T. ;
Kenny, J. ;
Langton, C. M. ;
Trapp, J. V. .
MEDICAL PHYSICS, 2014, 41 (10)
[8]   Monte Carlo-based diode design for correction-less small field dosimetry [J].
Charles, P. H. ;
Crowe, S. B. ;
Kairn, T. ;
Knight, R. T. ;
Hill, B. ;
Kenny, J. ;
Langton, C. M. ;
Trapp, J. V. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (13) :4501-4512
[9]   Origins of the changing detector response in small megavoltage photon radiation fields [J].
Fenwick, John D. ;
Georgiou, Georgios ;
Rowbottom, Carl G. ;
Underwood, Tracy S. A. ;
Kumar, Sudhir ;
Nahum, Alan E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (12)
[10]   Small field dosimetry correction factors for circular and MLC shaped fields with the CyberKnife M6 System: evaluation of the PTW 60023 microSilicon detector [J].
Francescon, P. ;
Kilby, W. ;
Noll, J. M. ;
Satariano, N. ;
Orlandi, C. .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (01)