Simulation and Design of Cold-cathode X-ray Tube Based on CNTs

被引:0
作者
Li, Yuan [1 ]
Zhu, Zhuoya [1 ]
Li, Haiyan [1 ]
Lei, Wei [1 ]
Zhang, Xiaobing [1 ]
机构
[1] Southeast Univ, Display Technol Ctr, Nanjing 210096, Jiangsu, Peoples R China
来源
2015 IEEE INTERNATIONAL VACUUM ELECTRONICS CONFERENCE (IVEC) | 2015年
关键词
X-ray tube; cold-cathode electron source; triode focusing structure;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The X-ray tube with a cold-cathode electron source has become a hot topic for its advantages of small volume, fast response. A triode focusing structure was designed to improve the focusing performance of the electron source. The X-ray tube imaging was performed to test the emission performance. The clear X-ray image of static object was obtained, reflecting the good emission and focusing performance of the X-ray tube.
引用
收藏
页数:2
相关论文
共 50 条
  • [21] Field Emission Behavior of Carbon Nanotube Yarn for Micro-Resolution X-Ray Tube Cathode
    Hwang, Jae Won
    Mo, Chan Bin
    Jung, Hyun Kyu
    Ryu, Seongwoo
    Hong, Soon Hyung
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2013, 13 (11) : 7386 - 7390
  • [22] A novel x-ray tube with a line filament
    Lee, SG
    Bak, JG
    Bitter, M
    More, R
    APPLICATIONS OF X RAYS GENERATED FROM LASERS AND OTHER BRIGHT SOURCES II, 2001, 4504 : 159 - 167
  • [23] Optimization of X-ray target parameters for a high-brightness microfocus X-ray tube
    Ihsan, Aamir
    Heo, Sung Hwan
    Cho, Sung Oh
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 264 (02) : 371 - 377
  • [24] A design of transmission-type multi-target X-ray tube based on electric field modulation
    Zhao, Lei
    Jia, Wenbao
    Jin, Limin
    Shan, Qing
    Cheng, Can
    Zhu, Hongkui
    Hei, Daqian
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (09) : 3026 - 3034
  • [25] Innovations in X-ray tube design and instrumentation for conventional radiological applications: a scoping review
    Alharbi, M. K. M.
    Zhou, Abel
    Naunton, Mark
    Davidson, Rob
    Makanjee, Chandra
    IMAGING SCIENCE JOURNAL, 2025,
  • [26] A novel X-ray tube spectra reconstruction method based on transmission measurements
    Jing Cao
    Chun-Yu Jiang
    Yan-Feng Zhao
    Qing-Wei Yang
    Ze-Jie Yin
    Nuclear Science and Techniques, 2016, 27
  • [27] A novel X-ray tube spectra reconstruction method based on transmission measurements
    Jing Cao
    Chun-Yu Jiang
    Yan-Feng Zhao
    Qing-Wei Yang
    Ze-Jie Yin
    NuclearScienceandTechniques, 2016, 27 (02) : 75 - 80
  • [28] A novel X-ray tube spectra reconstruction method based on transmission measurements
    Cao, Jing
    Jiang, Chun-Yu
    Zhao, Yan-Feng
    Yang, Qing-Wei
    Yin, Ze-Jie
    NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (02)
  • [29] X-ray tube with needle-like anode
    Slapa, M
    Stras, W
    Traczyk, M
    Dora, J
    Snopek, M
    Gutowski, R
    Drabik, W
    NUKLEONIKA, 2002, 47 (03) : 101 - 105
  • [30] DETERMINATION OF X-RAY TUBE FOCAL SPOT POSITION
    KUBOTA, H
    OZAKI, Y
    MATSUMOTO, M
    KANAMORI, H
    MEDICAL PHYSICS, 1993, 20 (04) : 1029 - 1031