Does the planning dose-volume histogram represent treatment doses in image-guided prostate radiation therapy? Assessment with cone-beam computerised tomography scans

被引:64
作者
Hatton, Joan A. [1 ,2 ]
Greer, Peter B. [2 ]
Tang, Colin [2 ]
Wright, Philip
Capp, Anne [2 ]
Gupta, Sanjiv
Parker, Joel
Wratten, Chris [2 ]
Denham, James W. [2 ]
机构
[1] Calvary Mater Newcastle, Trans Tasman Radiat Oncol Grp, Hunter Region Mail Ctr, Dept Radiat Oncol, Newcastle, NSW 2310, Australia
[2] Univ Newcastle, Callaghan, NSW 2308, Australia
关键词
Radiotherapy; Cone beam computerised tomography; Dose-volume histogram; Prostate; Rectum; INTENSITY-MODULATED RADIOTHERAPY; CANCER RADIOTHERAPY; INCREASED RISK; CT; INTEROBSERVER; TOXICITY; GUIDANCE; FAILURE; RECTUM; TRIAL;
D O I
10.1016/j.radonc.2011.01.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the accuracy of the initial CT plan dose-volume histograms (DVH's) for prostate, rectum and bladder by comparison to delivered doses determined from cone beam CT (CBCT) scans acquired during image-guided treatment. Materials and methods: Twelve prostate patients were treated using daily implanted fiducial guidance and following local protocol for bladder and rectal preparation. CBCT scans were acquired twice weekly and contoured for prostate, rectum and bladder. The planned beams were applied to all CBCT scans to determine the delivered doses. Prostate dose coverage was assessed by the proportion of the CTV fully encompassed by the 95% and 98% isodose lines. Rectal and bladder volumes receiving 40 Gy, 60 Gy and 70 Gy at treatment were compared to the initial plan, with significance determined using the one-sample t-test. Results: Four patients showed marginally compromised CTV coverage by the 95% isodose at all CBCT plans. For nine patients the initial plan rectal DVH was significantly outside the range of the treatment DVH's. Conclusions: Dose coverage of the prostate was not achieved for all patients. Observed rectal and bladder doses were higher than predicted. The initial treatment plan cannot be assumed to represent accurate normal tissue doses. Crown Copyright (C) 2011 Published by Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 98 (2011) 162-168
引用
收藏
页码:162 / 168
页数:7
相关论文
共 39 条
[1]  
[Anonymous], 1993, J ICRU
[2]  
[Anonymous], 1999, 62 ICRU
[3]   Assessing correlations between the spatial distribution of the dose to the rectal wall and late rectal toxicity after prostate radiotherapy: an analysis of data from the MRC RT01 trial (ISRCTN 47772397) [J].
Buettner, Florian ;
Gulliford, Sarah L. ;
Webb, Steve ;
Sydes, Matthew R. ;
Dearnaley, David P. ;
Partridge, Mike .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (21) :6535-6548
[4]   Rectal dose variation during the course of image-guided radiation therapy of prostate cancer [J].
Chen, Lili ;
Paskalev, Kamen ;
Xu, Xiu ;
Zhu, Jennifer ;
Wang, Lu ;
Price, Robert A. ;
Hu, Wei ;
Feigenberg, Steven J. ;
Horwitz, Eric M. ;
Pollack, Alan ;
Ma, C. M. Charlie .
RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) :198-202
[5]   Investigation of bladder dose and volume factors influencing late urinary toxicity after external beam radiotherapy for prostate cancer [J].
Cheung, M. Rex ;
Tucker, Susan L. ;
Dong, Lei ;
de Crevoisier, Renaud ;
Lee, Andrew K. ;
Frank, Steven ;
Kudchadker, Rajat J. ;
Thames, Howard ;
Mohan, Radhe ;
Kuban, Deborah .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04) :1059-1065
[6]   Evaluation of a contour-alignment technique for CT-guided prostate radiotherapy: An intra- and interobserver study [J].
Court, LE ;
Dong, L ;
Taylor, N ;
Ballo, M ;
Kitamura, K ;
Lee, AK ;
O'Daniel, J ;
White, RA ;
Cheung, R ;
Kuban, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (02) :412-418
[7]   Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy [J].
De Crevoisier, R ;
Tucker, SL ;
Dong, L ;
Mohan, R ;
Cheung, R ;
Cox, JD ;
Kuban, DA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04) :965-973
[8]  
DENHAM J, 2003, 03 04 RANDOMISED TRI
[9]   Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy [J].
Ding, George X. ;
Duggan, Dennis M. ;
Coffey, Charles W. .
MEDICAL PHYSICS, 2008, 35 (03) :1135-1144
[10]   CONFORMAL ARC RADIOTHERAPY FOR PROSTATE CANCER: INCREASED BIOCHEMICAL FAILURE IN PATIENTS WITH DISTENDED RECTUM ON THE PLANNING COMPUTED TOMOGRAM DESPITE IMAGE GUIDANCE BY IMPLANTED MARKERS [J].
Engels, Benedikt ;
Soete, Guy ;
Verellen, D. ;
Storme, Guy .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (02) :388-391