Multiresidue analysis of acidic and polar organic contaminants in water samples by stir-bar sorptive extraction-liquid desorption-gas chromatography-mass spectrometry

被引:194
作者
Quintana, Jose Benito [1 ]
Rodil, Rosario [2 ]
Muniategui-Lorenzo, Soledad [2 ]
Lopez-Mahia, Purificacion [1 ,2 ]
Prada-Rodriguez, Dario [1 ,2 ]
机构
[1] Univ A Coruna, Univ Inst Environm, IUMA, Oleiros 15179, A Coruna, Spain
[2] Univ A Coruna, Fac Sci, Dept Analyt Chem, La Coruna 15071, Spain
关键词
phenols; pharmaceuticals; herbicides; water samples; stir-bar sorptive extraction (SBSE); derivatisation; silylation; programmed temperature vaporisation (PTV); large volume injection (LVI); gas chromatography-mass spectrometry (GC-MS);
D O I
10.1016/j.chroma.2007.07.088
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The feasibility of stir-bar sorptive extraction (SBSE) followed by liquid desorption in combination with large volume injection (LVI)-in port silylation and gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of a broad range of 46 acidic and polar organic pollutants in water samples has been evaluated. The target analytes included phenols (nitrophenols, chlorophenols, bromophenols and alkylphenols), acidic herbicides (phenoxy acids and dicamba) and several pharmaceuticals. Experimental variables affecting derivatisation yield and peak shape as a function of different experimental PTV parameters [initial injection time, pressure and temperature and the ratio solvent volume/N-(tert-butyldimethylsilyl)-N-methyltrifluoroacetamide (MTBSTFA) volume] were first optimised by an experimental design approach. Subsequently, SBSE conditions, such as pH, ionic strength, agitation speed and extraction time were investigated. After optimisation, the method failed only for the extraction of most polar phenols and some pharmaceuticals, being suitable for the determination of 37 (out of 46) pollutants, with detection limits for these analytes ranging between I and 800 ng/L and being lower than 25 ng/L in most cases. Finally, the developed method was validated and applied to the determination of target analytes in various aqueous environmental matrices, including ground, river and wastewater. Acceptable accuracy (70-130%) and precision values (<20%) were obtained for most analytes independently of the matrix, with the exception of some alkylphenols, where an isotopically labelled internal standard would be required in order to correct for matrix effects. Among the drawbacks of the method, carryover was identified as the main problem even though the Twisters were cleaned repeatedly. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 39
页数:13
相关论文
共 44 条
[1]  
Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
[2]  
2-4
[3]   Dual-phase twisters: A new approach to headspace sorptive extraction and stir bar sorptive extraction [J].
Bicchi, C ;
Cordero, C ;
Liberto, E ;
Rubiolo, P ;
Sgorbini, B ;
David, F ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1094 (1-2) :9-16
[4]   Simultaneous determination of neutral and acidic pesticides in natural waters at the low nanogram per liter level [J].
Bucheli, TD ;
Gruebler, FC ;
Muller, SR ;
Schwarzenbach, RP .
ANALYTICAL CHEMISTRY, 1997, 69 (08) :1569-1576
[5]   OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION CONDITIONS FOR DETERMINATION OF PHENOLS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :160-167
[6]   Aquatic degradation of triclosan and formation of toxic chlorophenols in presence of low concentrations of free chlorine [J].
Canosa, P ;
Morales, S ;
Rodríguez, I ;
Rubí, E ;
Cela, R ;
Gómez, M .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (7-8) :1119-1126
[7]  
DEMAAGD PGJ, 2006, P 3 SCREEN METH WAT
[8]   Analysis of chlorophenoxy acid herbicides in water by large-volume on-line derivatization and gas chromatography-mass spectrometry [J].
Ding, WH ;
Liu, CH ;
Yeh, SP .
JOURNAL OF CHROMATOGRAPHY A, 2000, 896 (1-2) :111-116
[9]  
HAJSLOVA J, 1988, J CHROMATOGR, V439, P307
[10]   Detection of more than 50 substituted phenols as their t-butyldimethylsilyl derivatives using gas chromatography mass spectrometry [J].
Heberer, T ;
Stan, HJ .
ANALYTICA CHIMICA ACTA, 1997, 341 (01) :21-34