Cooling load characteristics of indoor spaces conditioned by decoupled radiant cooling unit with low radiant temperature

被引:11
作者
Liang, Yuying [1 ]
Zhang, Nan [1 ]
Wu, Huijun [2 ]
Xu, Xinhua [3 ]
Yang, Jianming [4 ]
Huang, Gongsheng [1 ]
机构
[1] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Peoples R China
[2] Guangzhou Univ, Sch Civil Engn, Guangzhou 510006, Peoples R China
[3] Huazhong Univ Sci & Technol, Dept Bldg Environm & Energy Engn, Wuhan, Peoples R China
[4] Guangdong Polytech Normal Univ, Sch Automat, Guangzhou 510665, Peoples R China
基金
中国国家自然科学基金;
关键词
radiant cooling; condensation-free; computational fluid dynamics; cooling load; hot and humid climates; THERMAL PERFORMANCE; SYSTEM; VENTILATION; SIMULATION; PANELS; WALL;
D O I
10.1007/s12273-022-0919-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
Decoupled radiant cooling units (DRCUs) are capable of increasing the cooling capacity without increasing condensation risks even using a much lower cooling temperature than conventional radiant cooling units (CRCUs). However, it is unclear whether DRCUs using low radiant cooling temperature will increase the cooling load of the conditioned indoor spaces. In this study, the cooling load characteristics of a thermal chamber conditioned by a DRCU was investigated through developing a steady-state analysis model suitable for both DRCUs and CRCUs. The total/radiative heat flux, as well as the heat exchange with a thermal manikin and walls were analysed under different surface temperatures of DRCUs. The effect of the emissivity of the thermal chamber' external wall on the cooling load was also investigated. Results indicated that the cooling load under the DRCU was slightly smaller than that under the CRCU when the same operative environment was created. Decreasing the infrared emissivity of the exterior wall's inner surface could lead to a significant decrease in the cooling load for both the DRCU and CRCU. By decreasing the wall emissivity from 0.9 to 0.1, the total cooling load of the DRCU can be decreased by 8.4% and the heat gain of the exterior wall decreased by 21.6%. This study serves as a reference for developing the analysis model and understanding the load characteristics when DRCUs are used to create the thermal environment for indoor spaces.
引用
收藏
页码:2067 / 2079
页数:13
相关论文
共 43 条
[41]   Numerical study on indoor environment and thermal comfort in train station waiting hall with two different air-conditioning modes [J].
Zhuang, Biyao ;
Shi, Juan ;
Chen, Zhenqian .
BUILDING SIMULATION, 2021, 14 (02) :337-349
[42]   A decentralized method for energy conservation of an HVAC system [J].
Zhuang, Luping ;
Chen, Xi ;
Guan, Xiaohong .
BUILDING SIMULATION, 2020, 13 (01) :155-170
[43]   Applicability of high-temperature cooling systems in different European countries from the view of the condensation risk [J].
Zmrhal, Vladimir ;
Bartak, Martin .
BUILDING SIMULATION, 2021, 14 (05) :1453-1466