Analysing Gait Patterns in Degenerative Lumbar Spine Disease Using Inertial Wearable Sensors: An Observational Study

被引:8
作者
Natarajan, Pragadesh [1 ,3 ,4 ,5 ]
Fonseka, R. Dineth [1 ,3 ,4 ,5 ]
Sy, Luke Wincent [2 ]
Maharaj, Monish Movin [1 ,3 ,4 ,5 ]
Mobbs, Ralph Jasper [1 ,3 ,4 ,5 ]
机构
[1] Univ New South Wales, Fac Med, Sydney, NSW, Australia
[2] Univ New South Wales, Sch Math, Sydney, NSW, Australia
[3] Prince Wales Private Hosp, NeuroSpine Clin, Randwick, NSW, Australia
[4] NeuroSpine Surg Res Grp, Sydney, NSW, Australia
[5] Wearables & Gait Assessment Res Grp, Sydney, NSW, Australia
关键词
Accelerometry; Degenerative; Diagnosis; Gait analysis; Inertial measurement units; Lumbar spine; Patient assessment; Sensors; Wearables; LOW-BACK-PAIN; SELF-REPORT MEASURES; PARKINSONS-DISEASE; MUSCLE-ACTIVITY; FUSION SURGERY; OLDER-ADULTS; VARIABILITY; MOTION; ASSOCIATIONS; DISABILITY;
D O I
10.1016/j.wneu.2022.04.013
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: Using a chest-based inertial wearable sensor, we examined the quantitative gait patterns associated with lumbar disc herniation (LDH), lumbar spinal stenosis (LSS), and chronic mechanical low back pain (CMLBP). 'Pathological gait signatures' were reported as statistically significant group difference (%) from the 'normative' gait values of an age-matched control population. METHODS: A sample of patients presenting to the Prince of Wales Private Hospital (Sydney, Australia) with primary diagnoses of LDH, LSS, or CMLBP were recruited. Spatial, temporal, asymmetry, and variability metrics were compared with age-matched (+/- 2 years) control participants recruited from the community. Participants were fitted at the sternal angle with an inertial measurement unit, MetaMotionC, and walked unobserved (at a self-selected pace) for 120 m along an obstacle-free, carpeted hospital corridor. RESULTS: LDH, CMLBP, and LSS groups had unique pathological signatures of gait impairment. The LDH group (n = 33) had marked asymmetry in terms of step length, step time, stance, and single-support asymmetry. The LDH group also involved gait variability with increased step length variation. However, distinguishing the CMLBP group (n = 33) was gait variability in terms increased single-support time variation. The gait of participants with LSS (n = 22) was both asymmetric and variable in step length. CONCLUSIONS: Wearable sensor-based accelerometry was found to he capable of detecting the gait abnormalities present in patients with LDH, LSS, and CMLBP, when compared to age-matched controls. Objective and quantitative patterns of gait deterioration uniquely varied between these subtypes of lumbar spine disease. With further testing and validation, gait signatures may aid clinical identification of gait-altering pathologies.
引用
收藏
页码:E501 / E515
页数:15
相关论文
共 67 条
[1]   Assessment of Spatiotemporal Gait Parameters in Patients with Lumbar Disc Herniation and Patients with Chronic Mechanical Low Back Pain [J].
Amir Rashedi Bonab, Masoud ;
Kuru Colak, Tugba ;
Toktas, Zafer Orkun ;
Konya, Deniz .
TURKISH NEUROSURGERY, 2020, 30 (02) :277-284
[2]   Effect of investigator observation on gait parameters in individuals with stroke [J].
Ardestani, Marzieh M. ;
Hornby, T. George .
JOURNAL OF BIOMECHANICS, 2020, 100
[3]   Patients with chronic non-specific low back pain who reported reduction in pain and improvement in function also demonstrated an improvement in gait pattern [J].
Barzilay, Yair ;
Segal, Ganit ;
Lotan, Raphael ;
Regev, Gilad ;
Beer, Yiftah ;
Lonner, Baron S. ;
Mor, Amit ;
Elbaz, Avi .
EUROPEAN SPINE JOURNAL, 2016, 25 (09) :2761-2766
[4]   Gait Variability among Healthy Adults: Low and High Stride-to-Stride Variability Are Both a Reflection of Gait Stability [J].
Beauchet, Olivier ;
Allali, Gilles ;
Annweiler, Cedric ;
Bridenbaugh, Stephanie ;
Assal, Frederic ;
Kressig, Reto W. ;
Herrmann, Francois R. .
GERONTOLOGY, 2009, 55 (06) :702-706
[5]  
Betteridge C, J ORTHOP SURG RES, V16, P1
[6]  
Betteridge C, J SPINE SURG, V7, P254
[7]   Classification of foot drop gait characteristic due to lumbar radiculopathy using machine learning algorithms [J].
Bidabadi, Shiva Sharif ;
Murray, Iain ;
Lee, Gabriel Yin Foo ;
Morris, Susan ;
Tan, Tele .
GAIT & POSTURE, 2019, 71 :234-240
[8]   Independent and sensitive gait parameters for objective evaluation in knee and hip osteoarthritis using wearable sensors [J].
Boekesteijn, Ramon J. ;
Smolders, Jose M. H. ;
Busch, Vincent J. J. F. ;
Geurts, Alexander C. H. ;
Smulders, Katrijn .
BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
[9]   On the definitions and physiology of back pain, referred pain, and radicular pain [J].
Bogduk, Nikolai .
PAIN, 2009, 147 (1-3) :17-19
[10]   Wearable pendant device monitoring using new wavelet-based methods shows daily life and laboratory gaits are different [J].
Brodie, Matthew A. D. ;
Coppens, Milou J. M. ;
Lord, Stephen R. ;
Lovell, Nigel H. ;
Gschwind, Yves J. ;
Redmond, Stephen J. ;
Del Rosario, Michael Benjamin ;
Wang, Kejia ;
Sturnieks, Daina L. ;
Persiani, Michela ;
Delbaere, Kim .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (04) :663-674