Hybrid radiofrequency and cryoablation device: Preliminary results in an animal model

被引:40
作者
Hines-Peralta, A [1 ]
Hollander, CY [1 ]
Solazzo, S [1 ]
Horkan, C [1 ]
Liu, ZJ [1 ]
Goldberg, SN [1 ]
机构
[1] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
关键词
D O I
10.1097/01.RVI.0000136031.91939.EC
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine whether the simultaneous application of combined bipolar radiofrequency (RF) ablation and cryoablation in a hybrid system produces larger ablation zones than RF or cryoablation alone. MATERIALS AND METHODS: Multiple 15-minute ablations were performed in ex vivo bovine liver (n = 167) with a hybrid applicator system with RF ablation alone (0.3-0.7 A), cryoablation alone (3,500 psi, two freeze/thaw cycles), and combined RF/cryoablation (0.4-0.7 A, 1,000-3,500 psi) with use of a novel applicator consisting of two 2.5-cm active bipolar RF poles located on the same 18-gauge needle separated by two embedded cryoablation nozzles. Resultant coagulation diameters were compared with use of analysis of variance for more than three groups or Student t tests for two groups. Confirmation of the optimal parameters of combination RF/cryoablation was performed by reassessing a range of argon pressure (1,000-3,500 psi) and RF current (0.4-0.7 A) in in vivo porcine liver (n = 36). Arrays of two to four RF/cryoablation applicators were also assessed in ex vivo (n = 54) and in vivo (n = 12) liver. RESULTS: In ex vivo liver, simultaneous RF/cryoablation (0.6 A, 3,000 psi) produced 3.6 cm +/- 0.4 of short-axis coagulation. This was significantly larger than that achieved with optimal RF alone or cryoablation alone (1.5 cm +/- 0.3 and 1.6 cm +/- 0.3, respectively; F = 95; P < .01). The coagulation diameter with simultaneous combination RF/cryoablation was related in parabolic fashion to argon pressure and current with a multivariate r(2) of 0.68. For in vivo liver, optimal combination RF/cryoablation achieved 3.3 cm +/- 0.2 of coagulation, which was significantly larger than that achieved with RF alone (1.1 cm +/- 0.1; P < .01) or cryoablation alone (1.1 cm 0.1 and 1.3 cm +/- 0.1; F = 203; P < .01). The greatest contiguous coagulation was achieved with multiple-applicator arrays. For ex vivo liver, short-axis coagulation measured 5.3 cm +/- 0.1, 6.4 cm +/- 0.1, and 7.6 cm +/- 0.1 for two-, three-, and four-applicator arrays, respectively. For in vivo liver, two-, three-, and four-applicator arrays produced 5.1 cm +/- 0.2, 5.8 cm +/- 0.5, and 7.0 cm +/- 0.5 of confluent coagulation, respectively. CONCLUSION: Simultaneous combination RF and cryoablation with use of a novel applicator design yielded significantly larger zones of coagulation than either modality alone. The large ablation diameters achieved warrant further investigation of the device.
引用
收藏
页码:1111 / 1120
页数:10
相关论文
共 39 条
[11]   CORRELATION OF ELECTRICAL-IMPEDANCE AND TEMPERATURE IN TISSUE DURING FREEZING [J].
GAGE, AA .
CRYOBIOLOGY, 1979, 16 (01) :56-62
[12]   Renal cell carcinoma: Clinical experience and technical success with radio-frequency ablation of 42 tumors [J].
Gervais, DA ;
McGovern, F ;
Arellano, RS ;
McDougal, WS ;
Mueller, PR .
RADIOLOGY, 2003, 226 (02) :417-424
[13]   Survival after percutaneous, image-guided, thermal ablation of hepatic metastases from colorectal cancer [J].
Gillams, AR ;
Lees, WR .
DISEASES OF THE COLON & RECTUM, 2000, 43 (05) :656-661
[14]   Percutaneous radiofrequency tissue ablation: Optimization of pulsed radiofrequency technique to increase coagulation necrosis [J].
Goldberg, SN ;
Stein, MC ;
Gazelle, GS ;
Sheiman, RG ;
Kruskal, JB ;
Clouse, ME .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (07) :907-916
[15]   Large-volume tissue ablation with radio frequency by using a clustered, internally cooled electrode technique: Laboratory and clinical experience in liver metastases [J].
Goldberg, SN ;
Solbiati, L ;
Hahn, PF ;
Cosman, E ;
Conrad, JE ;
Fogle, R ;
Gazelle, GS .
RADIOLOGY, 1998, 209 (02) :371-379
[16]   Thermal ablation therapy for focal malignancy: A unified approach to underlying principles, techniques, and diagnostic imaging guidance [J].
Goldberg, SN ;
Gazelle, GS ;
Mueller, PR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :323-331
[17]   Radio-frequency-induced coagulation necrosis in rabbits: Immediate detection at US with a synthetic microsphere contrast agent [J].
Goldberg, SN ;
Walovitch, RC ;
Straub, JA ;
Shore, MT ;
Gazelle, GS .
RADIOLOGY, 1999, 213 (02) :438-444
[18]  
GOLDBERG SN, 1995, ACAD RADIOL, V2, P399
[19]  
Goldberg SN, 1996, ACAD RADIOL, V3, P636
[20]   Radio-frequency thermal ablation with NaCl solution injection: Effect of electrical conductivity on tissue heating and coagulation-phantom and porcine liver study [J].
Goldberg, SN ;
Ahmed, M ;
Gazelle, GS ;
Kruskal, JB ;
Huertas, JC ;
Halpern, EF ;
Oliver, BS ;
Lenkinski, RE .
RADIOLOGY, 2001, 219 (01) :157-165