Sensitive Determination of Concentration of Nonfluorescent Species in an Extended-Nano Channel by Differential Interference Contrast Thermal Lens Microscope

被引:46
作者
Shimizu, Hisashi [1 ]
Mawatari, Kazuma [1 ]
Kitamori, Takehiko [1 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
基金
日本学术振兴会;
关键词
LONG DNA-MOLECULES; SEPARATION; SYSTEM; INTEGRATION;
D O I
10.1021/ac1017088
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A photothermal detector, named differential interference contrast thermal lens microscope (DIC-TLM), was used to determine the concentration of a nonfluorescent solution in a nanochannel. This method exploits a local change in the refractive index of a solution caused by light absorption. A solution was introduced into a 100-nm scale channel by a pressure-driven nanofluidic control system and its concentration was determined by DIC-TLM. The limit of detection (LOD) was 2.4 mu M in a nanochannel that was 21 mu m wide and 500 nm deep. The LOD was 3 orders of magnitude smaller than that of conventional method. Moreover, the detection volume was accurately determined to be merely 0.25 fL by using a nanochannel with an optical path length of 500 nm. Based on these results, the number of detected molecules was calculated to be 390. In addition, the concentration of a solution in a nanochannel that was 790 nm wide and 500 nm deep could be determined. Finally, the relationship between sensitivity and channel size was investigated and the sensitivity was found to decrease with decreasing nanochannel size, which indicates that the changes in the refractive indices of water and silica cancel each other out. The DIC-TLM realizes sensitive detection of nonfluorescent species in nanochannels without requiring any special fabrication techniques. Therefore, DIC-TLM is expected to be a highly useful analytical technique in nanofluidics.
引用
收藏
页码:7479 / 7484
页数:6
相关论文
共 31 条
  • [1] Bialkowski S. E., 2019, PHOTOTHERMAL SPECTRO
  • [2] Chemical Analysis of Single Cells
    Borland, Laura M.
    Kottegoda, Sumith
    Phillips, K. Scott
    Allbritton, Nancy L.
    [J]. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2008, 1 : 191 - 227
  • [3] LASER-INDUCED THERMAL LENS EFFECT FOR CALORIMETRIC TRACE ANALYSIS
    DOVICHI, NJ
    HARRIS, JM
    [J]. ANALYTICAL CHEMISTRY, 1979, 51 (06) : 728 - 731
  • [4] Separation of long DNA molecules in a microfabricated entropic trap array
    Han, J
    Craighead, HG
    [J]. SCIENCE, 2000, 288 (5468) : 1026 - 1029
  • [5] THERMAL LENS CALORIMETRY
    HARRIS, JM
    DOVICHI, NJ
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (06) : A695 - &
  • [6] Microchemical systems for continuous-flow synthesis
    Hartman, Ryan L.
    Jensen, Klavs F.
    [J]. LAB ON A CHIP, 2009, 9 (17) : 2495 - 2507
  • [7] Nanochannels on a fused-silica microchip and liquid properties investigation by time-resolved fluorescence measurements
    Hibara, A
    Saito, T
    Kim, HB
    Tokeshi, M
    Ooi, T
    Nakao, M
    Kitamori, T
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (24) : 6170 - 6176
  • [8] UV excitation thermal lens microscope for sensitive and nonlabeled detection of nonfluorescent molecules
    Hiki, S
    Mawatari, K
    Hibara, A
    Tokeshi, M
    Kitamori, T
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (08) : 2859 - 2863
  • [9] A nanochannel-based concentrator utilizing the concentration polarization effect
    Huang, Kuan-Da
    Yang, Ruey-Jen
    [J]. ELECTROPHORESIS, 2008, 29 (24) : 4862 - 4870
  • [10] Separation of long DNA molecules by quartz nanopillar chips under a direct current electric field
    Kaji, N
    Tezuka, Y
    Takamura, Y
    Ueda, M
    Nishimoto, T
    Nakanishi, H
    Horiike, Y
    Baba, Y
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (01) : 15 - 22