Investigation of partial discharge phenomena in HTS transformer adopting different type of sensors

被引:6
作者
Koo, J. Y. [1 ]
Lee, S. H. [1 ]
Lee, Y. J. [1 ]
Lee, B. W. [1 ]
机构
[1] Hanyang Univ, Sch Elect Engn & Comp Sci, Ansan Shi 425791, Gyeonggi Do, South Korea
来源
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS | 2010年 / 470卷 / 20期
关键词
HTS transformer; Liquid nitrogen; Partial discharge sensor;
D O I
10.1016/j.physc.2010.05.187
中图分类号
O59 [应用物理学];
学科分类号
摘要
In this work, we proposed the partial discharge diagnostic techniques to evaluate the cryogenic dielectric insulation of high temperature superconducting (HTS) transformers. Three kinds of different artificial defects were fabricated in order to evaluate partial discharge (PD) characteristics of HIS transformers. Various PD sensors were installed to evaluate the performance of PD detecting characteristics in liquid nitrogen. From the experiments, it was possible to analyze PD signals and to discriminate what kinds of defects exist in cryogenic liquids using various types of PD sensors. Among three PD sensors, AE sensor and HFCT sensor showed more stable performances compared to UHF sensor. But according to the characteristics of defects, three sensors showed different sensitivities according to the PD signal frequency bandwidth of artificial defects. Consequently, this PD measuring technique could be utilized to establish the diagnostic devices for HTS transformer. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1684 / 1690
页数:7
相关论文
共 8 条