Multiscale Analyses of the Bone-implant Interface

被引:110
作者
Cha, J. Y. [1 ,2 ]
Pereira, M. D. [1 ]
Smith, A. A. [1 ]
Houschyar, K. S. [1 ]
Yin, X. [1 ,3 ]
Mouraret, S. [1 ]
Brunski, J. B. [1 ]
Helms, J. A. [1 ]
机构
[1] Stanford Sch Med, Div Plast & Reconstruct Surg, Dept Surg, Stanford, CA USA
[2] Yonsei Univ, Coll Dent, Orthodont Dept, Seoul 120749, South Korea
[3] Sichuan Univ, State Key Lab Oral Dis, West China Hosp Stomatol, Chengdu 610064, Peoples R China
关键词
dental implantation; prosthesis implantation; orthodontic anchorage techniques; finite element analysis; osseointegration; biological process; INSERTION TORQUE;
D O I
10.1177/0022034514566029
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Implants placed with high insertion torque (IT) typically exhibit primary stability, which enables early loading. Whether high IT has a negative impact on peri-implant bone health, however, remains to be determined. The purpose of this study was to ascertain how peri-implant bone responds to strains and stresses created when implants are placed with low and high IT. Titanium micro-implants were inserted into murine femurs with low and high IT using torque values that were scaled to approximate those used to place clinically sized implants. Torque created in peri-implant tissues a distribution and magnitude of strains, which were calculated through finite element modeling. Stiffness tests quantified primary and secondary implant stability. At multiple time points, molecular, cellular, and histomorphometric analyses were performed to quantitatively determine the effect of high and low strains on apoptosis, mineralization, resorption, and collagen matrix deposition in peri-implant bone. Preparation of an osteotomy results in a narrow zone of dead and dying osteocytes in peri-implant bone that is not significantly enlarged in response to implants placed with low IT. Placing implants with high IT more than doubles this zone of dead and dying osteocytes. As a result, peri-implant bone develops micro-fractures, bone resorption is increased, and bone formation is decreased. Using high IT to place an implant creates high interfacial stress and strain that are associated with damage to peri-implant bone and therefore should be avoided to best preserve the viability of this tissue.
引用
收藏
页码:482 / 490
页数:9
相关论文
共 18 条
[1]  
[Anonymous], COCHRANE DATABASE SY
[2]   ALTERATIONS TO THE EN-BLOC BASIC FUCHSIN STAINING PROTOCOL FOR THE DEMONSTRATION OF MICRODAMAGE PRODUCED IN-VIVO [J].
BURR, DB ;
HOOSER, M .
BONE, 1995, 17 (04) :431-433
[3]   BONE REMODELING IN RESPONSE TO INVIVO FATIGUE MICRODAMAGE [J].
BURR, DB ;
MARTIN, RB ;
SCHAFFLER, MB ;
RADIN, EL .
JOURNAL OF BIOMECHANICS, 1985, 18 (03) :189-&
[4]  
Calandriello Roberto, 2003, Clin Implant Dent Relat Res, V5 Suppl 1, P10, DOI 10.1111/j.1708-8208.2003.tb00011.x
[5]   Miniscrew stability evaluated with computerized tomography scanning [J].
Cha, Jung-Yul ;
Kil, Jae-Kyoung ;
Yoon, Tae-Min ;
Hwang, Chung-Ju .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (01) :73-79
[6]   The use of small titanium screws for orthodontic anchorage [J].
Deguchi, T ;
Takano-Yamamoto, T ;
Kanomi, R ;
Hartsfield, JK ;
Roberts, WE ;
Garetto, LP .
JOURNAL OF DENTAL RESEARCH, 2003, 82 (05) :377-381
[7]   Histological, histomorphometrical, and radiological evaluation of an experimental implant design with a high insertion torque [J].
Duyck, Joke ;
Corpas, Livia ;
Vermeiren, Stephanie ;
Ogawa, Toru ;
Quirynen, Marc ;
Vandamme, Katleen ;
Jacobs, Reinhilde ;
Naert, Ignace .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (08) :877-884
[8]   Clinical outcome and bone healing of implants placed with high insertion torque: 12-month results from a multicenter controlled cohort study [J].
Grandi, T. ;
Guazzi, P. ;
Samarani, R. ;
Grandi, G. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 42 (04) :516-520
[9]  
Higuchi K.W., 2000, Orthodontic Applications of Osseointegrated Implants
[10]   Effect of mechanical stimuli on skeletal regeneration around implants [J].
Leucht, Philipp ;
Kim, Jae-Beom ;
Wazen, Rima ;
Currey, Jennifer A. ;
Nanci, Antonio ;
Brunski, John B. ;
Heims, Jill A. .
BONE, 2007, 40 (04) :919-930