A sensitive chemiluminescence flow system for the determination of sulfite

被引:16
|
作者
Huang, YM
Zhang, C
Zhang, XR
Zhang, ZJ [1 ]
机构
[1] Shaanxi Normal Univ, Dept Chem, Xian 710062, Peoples R China
[2] Nanjing Univ, Dept Chem, Nanjing 210008, Peoples R China
[3] SW Normal Univ, Dept Chem, Chongqing 400715, Peoples R China
关键词
FIA; chemiluminescence; immobilized reagent; sulfite; sulfur dioxide;
D O I
10.1080/00032719908542890
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel chemiluminescence (CL) now system for sulfite with flow-injection analysis is presented in this paper. It is based on the wet chemiluminescence produced by auto-oxidation of sulfite in the presence of Rh6G, immobilized electrostatically on a cation exchange column. Tween 80 surfactant micelles showed a strong enhancement effect on this weak chemiluminescence. The system responds linearly to sulfite concentration in the range of 0.01-5 mg l(-1) (r(2)=0.996) with a detection limit (3 sigma) of 0.01 mg l(-1). Interfering metal ions coexisting in sample solutions could be effectively eliminated on-line by an upstream cation exchanger. A complete analysis could be performed in 1 min with a relative standard deviation of less than 5% (n=11). The system is stable for over 500 determinations and has been successfully applied to the determination of sulfite in VK3 injections and sulfur dioxide in air.
引用
收藏
页码:1211 / 1224
页数:14
相关论文
共 50 条
  • [1] Chemiluminescence flow system for the determination of sulfite
    Qin, W
    Zhang, ZJ
    Zhang, CJ
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (08): : 824 - 826
  • [2] Chemiluminescence flow system for the determination of sulfite
    Wei Qin
    Z.-J. Zhang
    Cheng-Jie Zhang
    Fresenius' Journal of Analytical Chemistry, 1998, 361 : 824 - 826
  • [3] FLOW-INJECTION CHEMILUMINESCENCE DETERMINATION OF SULFITE
    ALTAMRAH, SA
    TOWNSHEND, A
    WHEATLEY, AR
    ANALYST, 1987, 112 (06) : 883 - 886
  • [4] Flow-injection chemiluminescence determination of papaverine using cerium(IV)-sulfite system
    Zhang, S
    Zhuang, YF
    Ju, HX
    ANALYTICAL LETTERS, 2004, 37 (01) : 143 - 155
  • [5] Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system
    Li-Juan Wang1
    2 Institute of Analytical Sciences
    Journal of Pharmaceutical Analysis, 2011, 1 (01) : 51 - 56
  • [6] Flow injection chemiluminescence determination of loxoprofen and naproxen with the acidic permanganate-sulfite system
    Wang, Li-Juan
    Thng, Yu-Hai
    Liu, Yang-Hao
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2011, 1 (01) : 51 - 56
  • [7] Reversed Flow Injection Chemiluminescence Determination of Pyridoxine Hydrochloride Based on the Cerium(IV)-Sodium Sulfite System
    Sun, Shuwen
    Zhou, Fulin
    Wang, Gaofeng
    Li, Yawei
    Zhou, Juxiang
    Zhang, Chenwei
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 48 - 57
  • [8] Reagentless chemiluminescence flow sensor for sulfite
    Qin, W
    Zhang, ZJ
    Zhang, CJ
    ANALYTICA CHIMICA ACTA, 1998, 361 (03) : 201 - 203
  • [9] Sensitive determination of synephrine by flow-injection chemiluminescence
    Li, Q
    Huang, CZ
    Huang, YM
    LUMINESCENCE, 2006, 21 (01) : 43 - 48
  • [10] A sensitive flow injection chemiluminescence method for the determination of progesterone
    Cao, Wei
    Gong, Pixue
    Liu, Wenwen
    Zhuang, Mei
    Yang, Jinghe
    DRUG TESTING AND ANALYSIS, 2013, 5 (04) : 242 - 246