A novel optical configuration for inductively coupled plasma (ICP)-atomic emission spectrometry is presented. Plasma emission is measured axially via the bottom end of the ICP torch. Analytical performance, such as increase in signal-to-background ratio (SBR) over radially viewed ICP and linear dynamic range, is comparable to that of end-on axially viewed ICP reported in the literatures. Under typical ICP operating conditions (forward power = 1.0-1.6 kW, central channel gas flow rate = 0.8-1.4 l/min), SBR is generally five times or more that of radial-viewing mode (observation heights=3-20 mm) for atomic lines of elements of low to medium ionization potential (Na, K, Sr and Ba). The enhancement factor in SBR is two to four times for ionic lines (e.g. MgII) and atomic lines of elements of high ionization potential (Zn). The influence of ICP forward power and carrier gas flow rate on analyte emission intensity and SBR were also studied. Similar to radially viewed ICP, as forward power increases, the net emission intensity increases and SBR decreases. Using a constant flux of analyte aerosols, the net intensity decreases as the central channel gas flow rate increases. No trend of SBR vs. central channel gas flow rate, however, is found. The linear dynamic range starts and ends at analyte concentration 0.5-1 order of magnitude lower than the corresponding radial-viewing mode. As a result, the span of linear dynamic range is similar for all viewing modes. Matrix effects of K and Ca on atomic lines are different from those reported for end-on axially viewed ICPs, probably due to the difference in the plasma regions that were probed. The matrix effects on ionic lines, however, are similar in magnitude. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 58
页数:18
相关论文
共 40 条
[1]   SPECTROMETRIC STUDY ON RADIOFREQUENCY INDUCED PLASMA .1. ANALYTICAL PERFORMANCE [J].
ABDALLAH, MH ;
DIEMIASZONEK, R ;
JAROSZ, J ;
MERMET, JM ;
ROBIN, J ;
TRASSY, C .
ANALYTICA CHIMICA ACTA, 1976, 84 (02) :271-282
[2]  
[Anonymous], 1997, Concepts, Instrumentation, and Techniques in Inductively Coupled Plasma Optical Emission Spectrometry
[3]   A SPECTROMETRIC STUDY OF A 40 MHZ INDUCTIVELY COUPLED PLASMA .6. ARGON CONTINUUM IN THE VISIBLE REGION OF THE SPECTRUM [J].
BATAL, A ;
JAROSZ, J ;
MERMET, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1981, 36 (10) :983-992
[4]   THE VERTICAL SPATIAL CHARACTERISTICS OF ANALYTE EMISSION IN THE INDUCTIVELY COUPLED PLASMA [J].
BLADES, MW ;
HORLICK, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1981, 36 (09) :861-880
[5]  
Boumans P.W.J.M., 1987, INDUCTIVELY COUPLED, P100
[6]   EXPERIMENTAL-STUDY OF A 1-KW, 50-MHZ RF INDUCTIVELY COUPLED PLASMA WITH PNEUMATIC NEBULIZER, AND A DISCUSSION OF EXPERIMENTAL-EVIDENCE FOR A NONTHERMAL MECHANISM [J].
BOUMANS, PWJM ;
DEBOER, FJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1977, 32 (9-10) :365-395
[7]  
BOUMANS PWJM, 1984, SPECTROCHIM ACTA B, V39, P1261, DOI 10.1016/0584-8547(84)80211-6
[8]   ANALYSIS OF THE LIMITING NOISE AND IDENTIFICATION OF SOME FACTORS THAT DICTATE THE DETECTION LIMITS IN A LOW-POWER INDUCTIVELY COUPLED ARGON PLASMA SYSTEM [J].
BOUMANS, PWJM ;
MCKENNA, RJ ;
BOSVELD, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1981, 36 (11) :1031-1058
[9]   Compensation of Ca and Na interference effects in axially and radially viewed inductively coupled plasmas [J].
Brenner, IB ;
Le Marchand, A ;
Daraed, C ;
Chauvet, L .
MICROCHEMICAL JOURNAL, 1999, 63 (03) :344-355
[10]   Axially and radially viewed inductively coupled plasmas - a critical review [J].
Brenner, IB ;
Zander, AT .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (08) :1195-1240