Improving the energy sustainability of a Swiss village through building renovation and renewable energy integration

被引:57
作者
Le Guen, Morgane [1 ]
Mosca, Lucas [1 ]
Perera, A. T. D. [1 ]
Coccolo, Silvia [1 ]
Mohajeri, Nahid [1 ,2 ]
Scartezzini, Jean-Louis [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Solar Energy & Bldg Phys Lab LESO PB, CH-1015 Lausanne, Switzerland
[2] Univ Oxford, Dept Continuing Educ, Sustainable Urban Dev Programme, Rewley House,1 Wellington Sq, Oxford OX1 2JA, England
基金
瑞士国家科学基金会;
关键词
Energy sustainability; Building retrofitting; Building integrated PV panels; Energy hubs; MULTIPERIOD OPTIMIZATION; ELECTRICAL HUBS; WIND TURBINES; SYSTEMS; EFFICIENCY; COMMUNITY; EMISSION; NETWORK; DESIGN; IMPACT;
D O I
10.1016/j.enbuild.2017.10.057
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The integration of renewable energy technologies and building renovation are the two main procedures for improving energy sustainability of buildings at neighborhood scale. It is difficult, however, to optimize these procedures simultaneously. This study focuses on improving energy sustainability of Hemberg, a Swiss village with a population of about 900, through optimizing these two procedures. For this purpose a computational platform was developed, combining software CitySim, HOMER Pro, QGIS and Rhinoceros. The energy demand on hourly basis for the buildings in the village was analyzed through comparing the current demand with that after retrofitting according to the Swiss energy labels (i) Minergie and (ii) Minergie-P. Swiss energy maps were used to identify the most promising renewable energy sources while three scenarios were considered for solar PV integration and energy system improvements. The first scenario presents the current condition in the village, while the second scenario explores improvements in electricity generation and the third in both electricity and heat generation. The results show that retrofitting of all buildings according to Minergie reduces the space heating demand by 70-85% and reduces the fluctuations in energy demand, thereby allowing the integration of more renewable energy. According to the simulations, building-integrated solar PV panels can cover the total annual energy demand of the village when considering the Minergie and Minergie-P scenarios. However, the energy system assessment shows that it is difficult to reach beyond 60% when integrating non-dispatchable renewable energy technologies. Finally, and more importantly, integration of wind energy at system level has an important impact in the hub. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:906 / 923
页数:18
相关论文
共 47 条
[1]   Artificial neural network (ANN) based model predictive control (MPC) and optimization of HVAC systems: A state of the art review and case study of a residential HVAC system [J].
Afram, Abdul ;
Janabi-Sharifi, Farrokh ;
Fung, Alan S. ;
Raahemifar, Kaamran .
ENERGY AND BUILDINGS, 2017, 141 :96-113
[2]  
[Anonymous], INT EN OUTL 2016 BUI
[3]  
[Anonymous], 2005, Ergonomics of the thermal environment _ Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
[4]  
[Anonymous], 2015, P 2 BUILD SIM APPL C
[5]  
[Anonymous], P 9 INT C URB CLIM J
[6]   Quantifying rooftop photovoltaic solar energy potential: A machine learning approach [J].
Assouline, Dan ;
Mohajeri, Nahid ;
Scartezzini, Jean-Louis .
SOLAR ENERGY, 2017, 141 :278-296
[7]  
Athukorala AUCD, 2015, 2015 MORATUWA ENGINEERING RESEARCH CONFERENCE (MERCON), P182, DOI 10.1109/MERCon.2015.7112342
[8]   Energy refurbishment of the Italian residential building stock: energy and cost analysis through the application of the building typology [J].
Ballarini, Ilaria ;
Corrado, Vincenzo ;
Madonna, Francesco ;
Paduos, Simona ;
Ravasio, Franco .
ENERGY POLICY, 2017, 105 :148-160
[9]   Assessing thermal comfort and energy efficiency in buildings by statistical quality control for autocorrelated data [J].
Barbeito, Ines ;
Zaragoza, Sonia ;
Tarrio-Saavedra, Javier ;
Naya, Salvador .
APPLIED ENERGY, 2017, 190 :1-17
[10]  
Coccolo S., 2017, THESIS