Small Signal Stability of Fractional Frequency Transmission System With Offshore Wind Farms

被引:23
作者
Li, Jing [1 ,2 ]
Zhang, Xiao-Ping [1 ]
机构
[1] Univ Birmingham, Dept Elect Elect & Comp Engn, Birmingham B15 2TT, W Midlands, England
[2] State Grid Energy Res Inst, Future Sci & Technol Pk, Beijing 102209, Peoples R China
基金
英国工程与自然科学研究理事会;
关键词
Cycloconverter; DFIG; Fractional frequency transmission system (FFTS); small signal stability; TURBINE;
D O I
10.1109/TSTE.2016.2552540
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Fractional frequency transmission system (FFTS) is a relatively new transmission technology that can be used to deliver the energy from remote offshore wind farms, and it can increase the transmission capacity through the reduced transmission frequency. However, the dynamic performance of a FFTS with the wind farm may be different from that of a traditional ac transmission with the wind farm. In this paper, a doubly fed induction generator (DFIG)-based wind farm is connected to the main grid via the FFTS. The detailed dynamic model of the FFTS with wind farm is established first, and then the eigenvalue analysis is carried out to evaluate the system dynamic damping performance. To verify the results of eigenvalue analysis, dynamic simulations are carried out on a single machine infinite bus and a multimachine system. Both eigenvalue analysis and simulations demonstrate that the FFTS will have a negative influence on the damping of the DFIG-based wind farm in comparison to that of the wind farm with the traditional ac transmission system. However, with the control of cycloconverter, this problem can be easily overcome, and the damping performance of wind farm with FFTS can be even better.
引用
收藏
页码:1538 / 1546
页数:9
相关论文
共 19 条
  • [1] [Anonymous], POW SYST C EXP PSCE
  • [2] Bose B.K., 2002, MODERN POWER ELECT A
  • [3] Observer-based stator-flux-oriented vector control of cycloconverter-fed synchronous motor drive
    Das, SP
    Chattopadhyay, AK
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (04) : 943 - 955
  • [4] HILL W, 1990, CONFERENCE RECORD OF THE 1990 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETINGS, PARTS 1 AND 2, P1024, DOI 10.1109/IAS.1990.152310
  • [5] Kundur P., 1994, Power system stability and control
  • [6] Meliopoulos S. A. P., 2012, PSERC PUBLICATION, V12-28
  • [7] Improving Stability of a DFIG-Based Wind Power System With Tuned Damping Controller
    Mishra, Y.
    Mishra, S.
    Tripathy, M.
    Senroy, N.
    Dong, Z. Y.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (03) : 650 - 660
  • [8] Comparative study on transient stability analysis of wind turbine generator system using different drive train models
    Muyeen, S. M.
    Ali, Md. Hasan
    Takahashi, R.
    Murata, T.
    Tamura, J.
    Tomaki, Y.
    Sakahara, A.
    Sasano, E.
    [J]. IET RENEWABLE POWER GENERATION, 2007, 1 (02) : 131 - 141
  • [9] Ning Lianhui, 2011, 2011 4th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT 2011), P444, DOI 10.1109/DRPT.2011.5993932
  • [10] Pelly B.R., 1971, THYRISTOR PHASE CONT