Influence of the characteristics of isolation and mitigation devices on the response of single-degree-of-freedom vibro-impact systems with two-sided bumpers and gaps via shaking table tests

被引:30
作者
Andreaus, Ugo [1 ]
De Angelis, Maurizio [1 ]
机构
[1] Sapienza Univ Roma, Dipartimento Ingn Strutturale & Geotecn, Via Eudossiana 18, I-00184 Rome, Italy
关键词
displacement and acceleration control; seismic protection; shaking table; structural pounding; two-sided bumpers; vibro-impact system; ISOLATED BUILDINGS; SEISMIC RESPONSE; ADJACENT STRUCTURES; ELEVATED BRIDGES; GROUND MOTIONS; MODEL; SIMULATION; PERFORMANCE; REDUCTION; POUNDINGS;
D O I
10.1002/stc.2517
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
During strong earthquakes, structural pounding may occur between structures (buildings, bridges, strategic facilities, critical equipment, etc.) and the surrounding moat wall because of the limited separation distance and the deformations of the isolator. An arrangement that favors the solution of this problem is the interposition of shock absorbers. Thus, the influence of geometrical and mechanical characteristics of isolation and mitigation devices on nonlinear, nonsmooth response of vibro-impact systems is experimentally investigated in this paper on the basis of a laboratory campaign of experimental tests. Shaking table tests were carried out under a harmonic excitation in order to investigate two different configurations: the absence and the presence of bumpers. Three different values of the table acceleration peak were applied, four different amplitude values of the total gap between mass and bumpers were considered, and also four different types of bumpers were employed; moreover, two problems were addressed, namely, control of excessive displacements and control of excessive accelerations, and hence, two types of normalization were adopted in order to better interpret experimental results. Suitable choices of pairs of bumpers and gaps were suggested as a trade-off between conflicting objectives. Furthermore, a numerical model was proposed, and its governing parameters identified in order to simulate the experimental results.
引用
收藏
页数:21
相关论文
共 64 条
[41]  
Núñez K, 2007, REV TEC FAC ING UNIV, V30, P445
[42]   Structural performance of a base-isolated reinforced concrete building subjected to seismic pounding [J].
Pant, Deepak R. ;
Wijeyewickrema, Anil C. .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2012, 41 (12) :1709-1716
[43]   EARTHQUAKE SIMULATOR TESTING OF POUNDING BETWEEN ADJACENT BUILDINGS [J].
PAPADRAKAKIS, M ;
MOUZAKIS, HP .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1995, 24 (06) :811-834
[44]   A nonlinear impact model for simulating the use of rubber shock absorbers for mitigating the effects of structural pounding during earthquakes [J].
Polycarpou, Panayiotis C. ;
Komodromos, Petros ;
Polycarpou, Anastasis C. .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2013, 42 (01) :81-100
[45]  
Polycarpou PC, 2011, EARTHQ STRUCT, V2, P1
[46]   On poundings of a seismically isolated building with adjacent structures during strong earthquakes [J].
Polycarpou, Panayiotis C. ;
Komodromos, Petros .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2010, 39 (08) :933-940
[47]   Earthquake-induced poundings of a seismically isolated building with adjacent structures [J].
Polycarpou, Panayiotis C. ;
Komodromos, Petros .
ENGINEERING STRUCTURES, 2010, 32 (07) :1937-1951
[48]   Optimal energy-based seismic design of non-conventional Tuned Mass Damper (TMD) implemented via inter-story isolation [J].
Reggio, Anna ;
De Angelis, Maurizio .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2015, 44 (10) :1623-1642
[49]   Combined primary-secondary system approach to the design of an equipment isolation system with High-Damping Rubber Bearings [J].
Reggio, Anna ;
De Angelis, Maurizio .
JOURNAL OF SOUND AND VIBRATION, 2014, 333 (09) :2386-2403
[50]   Optimal design of an equipment isolation system with nonlinear hysteretic behaviour [J].
Reggio, Anna ;
De Angelis, Maurizio .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2013, 42 (13) :1907-1930