Influence of temperature and humidity on the electrical sensing of Pt/WO3 thin film hydrogen gas sensor

被引:19
作者
Yamaguchi, Yuki [1 ,3 ,4 ]
Imamura, Shunji [2 ]
Nishio, Keishi [2 ,3 ]
Fujimoto, Kenjiro [1 ,3 ]
机构
[1] Tokyo Univ Sci, Fac Sci & Technol, Dept Pure & Appl Chem, Noda, Chiba 2788510, Japan
[2] Tokyo Univ Sci, Fac Ind Sci & Technol, Dept Mat Sci & Technol, Katsushika, Tokyo 1258585, Japan
[3] Tokyo Univ Sci, Res Inst Sci & Technol, Noda, Chiba 2788510, Japan
[4] Natl Inst Adv Ind Sci & Technol, Tokyo, Japan
关键词
Hydrogen gas sensor; Tungsten oxide; Gasochomism; Sol-gel process; Humidity; TUNGSTEN-OXIDE; WO3; PLATINUM; OPPORTUNITIES; CHALLENGES; CATALYSTS; TRIOXIDE;
D O I
10.2109/jcersj2.15246
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Platinum catalyst loaded tungsten oxide (Pt/WO3) is a promising candidate as a hydrogen gas sensor material, which can detect it through optical and electrical sensing. The sensor, which can detect the hydrogen gas stably in various environments, is strongly demanded. In this study, we prepared the Pt/WO3 thin film by the sol-gel method and evaluate the dependence of the hydrogen gas sensing property on measuring temperature and humidity. Hydrogen gas sensing property of Pt/WO3 thin film was evaluated by measuring the electrical conductivity with humid (0-100% of relative humidity) hydrogen gas exposure at various temperatures. The sensing property was declined in humid atmospheres because the water molecule adsorbing on the film surface disturbed the catalytic reaction between hydrogen and Pt surface. In addition, the catalytic combustion of hydrogen molecule on Pt was also disturbed by the adsorbed water. However, the heating at 60 degrees C can remove the effect of water molecule and the film can detect hydrogen gas stably. From these results, it was considered that the degradation of sensor response in humid atmosphere was mainly dominated by adsorbing water on Pt catalyst surface. (C)2016 The Ceramic Society of Japan. All rights reserved.
引用
收藏
页码:629 / 633
页数:5
相关论文
共 17 条
[11]   A room-temperature operated hydrogen leak sensor [J].
Nakagawa, H ;
Yamamoto, N ;
Okazaki, S ;
Chinzei, T ;
Asakura, S .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 93 (1-3) :468-474
[12]   Absorption spectral response of nanotextured WO3 thin films with Pt catalyst towards H2 [J].
Yaacob, M. H. ;
Breedon, M. ;
Kalantar-zadeh, K. ;
Wlodarski, W. .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (01) :115-120
[13]   Influence of oxygen gas concentration on hydrogen sensing of Pt/WO3 thin film prepared by sol-gel process [J].
Yamaguchi, Yuki ;
Imamura, Shunji ;
Ito, Shigeru ;
Nishio, Keishi ;
Fujimoto, Kenjiro .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 216 :394-401
[14]   Hydrogen gas-sensing properties of Pt/WO3 thin film in various measurement conditions [J].
Yamaguchi, Yuki ;
Emoto, Yukari ;
Kineri, Tohru ;
Fujimoto, Masakatsu ;
Mae, Hideo ;
Yasumori, Atsuo ;
Nishio, Keishi .
IONICS, 2012, 18 (05) :449-453
[15]   Gasochromic effect in platinum-doped tungsten trioxide films prepared by the sol-gel method [J].
Zayat, M ;
Reisfeld, R ;
Minti, H ;
Orel, B ;
Svegl, F .
JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 1998, 11 (02) :161-168
[16]   Magnetron sputtered tungsten oxide films activated by dip-coated platinum for ppm-level hydrogen detection [J].
Zhang, Chao ;
Boudiba, Abdelhamid ;
Olivier, Marie-Georges ;
Snyders, Rony ;
Debliquy, Marc .
THIN SOLID FILMS, 2012, 520 (09) :3679-3683
[17]   Improved H2-sensing performance of nanocluster-based highly porous tungsten oxide films operating at moderate temperature [J].
Zhao, Meng ;
Ong, Chung Wo .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 174 :65-73