High-power time-domain measurement system with active harmonic load-pull for high-efficiency base-station amplifier design

被引:80
作者
Benedikt, J [1 ]
Gaddi, R
Tasker, PJ
Goss, M
机构
[1] Cardiff Univ, Sch Engn, Cardiff CF24 3TF, S Glam, Wales
[2] Nokia Networks, Camberley GU15 3BW, England
关键词
active load-pull; calibration; microwave measurements; microwave power amplifier; modeling; MOSFETs; nonlinearities; time-domain measurements;
D O I
10.1109/22.899021
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A measurement system combining vector corrected waveform measurements with active harmonic load-pull extends, for the first time, real-time experimental waveform engineering up to the 30-W power level. The vector correction procedure is presented in this paper, A novel harmonic load-pull approach based on the real-time measurement capability of the system is demonstrated on a 4-W LDMOS device, A 20% increase in maximum output power to 4.7 W without degrading gain and efficiency is realized, Waveform analysis at various drive and load conditions directly identifies nonlinear capacitance effects being a key design issue for the design of highly efficient power amplifier.