Determination of fluvoxamine and its metabolite fluvoxamino acid by liquid-liquid extraction and column-switching high-performance liquid chromatography

被引:16
|
作者
Yasui-Furukori, N
Inoue, Y
Kaneko, S
Otani, K
机构
[1] Hirosaki Univ, Sch Med, Dept Neuropsychiat, Hirosaki, Aomori 0368562, Japan
[2] Mitsubishi Pharma, Pharmaceut Technol Div, Fukuoka, Japan
[3] Yamagata Univ, Sch Med, Dept Neuropsychiat, Yamagata 99023, Japan
关键词
fluvoxamine; fluvoxamino acid; HPLC; column-switching;
D O I
10.1016/j.jpba.2004.09.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study describes a new simultaneous determination of fluvoxamine and fluvoxamino acid by automated column-switching high-performance liquid chromatography. The test compounds were extracted from 1.5 ml of plasma using chloroform-toluene (15:85, v/v), and the extract was injected into a hydrophilic metaacrylate polymer column for clean-up and a C18 analytical column for separation. The mobile phase for separation consisted of phosphate buffer (0.02 M, pH 4.6), acetonitrile and perchloric acid (60%) (62.4:37.5:0.1, v/v/v) and was delivered at a flow rate of 0.6 ml/min. The peak was detected using a UV detector set at 254 nm. The method was validated for the concentration range 0.8-153.6 ng/ml for fluvoxamine and 0.6-115.2 ng/ml for fluvoxamino acid, and their good linearity (r > 0.998) were confirmed. Intra-day coefficient variations (CVs) for fluvoxamine and fluvoxamino acid were less than 6.6 and 6.0%, respectively. Inter-day CVs for corresponding compounds were 6.3 and 6.5%, respectively. Relative errors ranged from -18 to 9% and mean recoveries were 96-100%. The limit of quantification was 1.2 and 0.9 ng/ml for fluvoxamine and fluvoxamino acid, respectively. This method shows successful application for pharmacokinetic studies and therapeutic drug monitoring. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:121 / 125
页数:5
相关论文
共 50 条
  • [1] Simultaneous determination of warfarin enantiomers and its metabolite in human plasma by column-switching high-performance liquid chromatography with chiral separation
    Uno, Tsukasa
    Niioka, Takenori
    Hayakari, Makoto
    Sugawara, Kazunobu
    Tateishi, Tomonori
    THERAPEUTIC DRUG MONITORING, 2007, 29 (03) : 333 - 339
  • [2] Sensitive determination of itraconazole and its active metabolite in human plasma by column-switching high-performance liquid chromatography with ultraviolet detection
    Uno, Tsukasa
    Shimizu, Mikiko
    Sugawara, Kazunobu
    Tateishi, Tomonori
    THERAPEUTIC DRUG MONITORING, 2006, 28 (04) : 526 - 531
  • [3] Simultaneous determination of methamphetamine and its metabolite, amphetamine, in urine using a high performance liquid chromatography column-switching method
    Kumihashi, Mitsuru
    Ameno, Kiyoshi
    Shibayama, Takayuki
    Suga, Keisuke
    Miyauchi, Hiroshi
    Jamal, Mostofa
    Wang, Weihuan
    Uekita, Ikuo
    Ijiri, Iwao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 845 (01): : 180 - 183
  • [4] Determination of lansoprazole and two of its metabolites by liquid-liquid extraction and automated column-switching high-performance liquid chromatography: application to measuring CYP2C19 activity
    Uno, T
    Yasui-Furukori, N
    Takahata, T
    Sugawara, K
    Tateishi, T
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 309 - 314
  • [5] Simultaneous determination of baicalin, rhein and berberine in rat plasma by column-switching high-performance liquid chromatography
    Li Yi
    Gao Jian-Ping
    Xu Xu
    Dai Lixin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 838 (01): : 50 - 55
  • [6] Sensitive column-switching high-performance liquid chromatography method for determination of propiverine in human plasma
    Ban, EM
    Maeng, JE
    Woo, JS
    Kim, CK
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 831 (1-2): : 230 - 235
  • [7] Determination of Niacinamide in Lotions and Creams Using Liquid-Liquid Extraction and High-Performance Liquid Chromatography
    Usher, Karyn M.
    Simmons, Carolyn R.
    Keating, Daniel W.
    Rossi, Henry F., III
    JOURNAL OF CHEMICAL EDUCATION, 2015, 92 (05) : 907 - 910
  • [8] Automated analysis of fluvoxamine in rat plasma using a column-switching system and ion-pair high-performance liquid chromatography
    Liu, Shicheng
    Shinkai, Norihiro
    Kakubari, Ikuhiro
    Saitoh, Hideo
    Noguchi, Ken-ichi
    Saitoh, Takashi
    Yamauchi, Hitoshi
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (12) : 1442 - 1449
  • [9] Determination of rabeprazole and its active metabolite, rabeprazole thioether in human plasma by column-switching high-performance liquid chromatography and its application to pharmacokinetic study
    Uno, T
    Yasui-Furukori, N
    Shimizu, M
    Sugawara, K
    Tateishi, T
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 824 (1-2): : 238 - 243
  • [10] Rapid and Simple Determination of Vitamin A and Vitamin E in Human Plasma by Column-Switching High-Performance Liquid Chromatography
    Sadilek, Petr
    Satinsky, Dalibor
    Ot'apka, Martin
    Sladkovsky, Radek
    Solich, Petr
    CURRENT ANALYTICAL CHEMISTRY, 2009, 5 (04) : 311 - 315