Angular distribution of coherent transition radiation from 6 MeV electron beam

被引:2
作者
Cha, V. A. [1 ]
Kalinin, B. N. [2 ]
Monastyrev, E. A. [3 ]
Naumenko, G. A. [2 ]
Potylitsyn, A. P. [1 ]
Saruev, G. A. [2 ]
Sukhikh, L. G. [1 ]
机构
[1] Tomsk Polytech Univ, Tomsk 634050, Russia
[2] Res Inst Nucl Phys, Tomsk 634034, Russia
[3] Res Inst Semicond Devices, Tomsk 634050, Russia
来源
INTERNATIONAL CONFERENCE ON CHARGED AND NEUTRAL PARTICLES CHANNELING PHENOMENA II - CHANNELING 2006 | 2007年 / 6634卷
关键词
coherent transition radiation; microtron; mm-technique; DIAGNOSTICS;
D O I
10.1117/12.741935
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Measurements of angular distribution of coherent transition radiation (CTR) from electron bunches with energy 6.1 MeV and length sigma(z) = 1.3 mm were carried out using the detector based on broadband antenna and high-frequency diode with resulting sensitivity 0.3 V/mW at a room temperature. Parabolic mirror use for CTR focusing rejects a pre-wave zone effect. The absolute value of the CTR power agrees with theoretical prediction within experimental accuracy level.
引用
收藏
页数:5
相关论文
共 10 条
[1]   Low-energy electron-beam diagnostics based on the optical transition radiation [J].
Aleinik, AN ;
Chefonov, OV ;
Kalinin, BN ;
Naumenko, GA ;
Potylitsyn, AP ;
Saruev, GA ;
Sharafutdinov, AF ;
Wagner, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 201 (01) :34-43
[2]   Measurements of coherent diffraction radiation and its application for bunch length diagnostics in particle accelerators [J].
Castellano, M ;
Verzilov, VA ;
Catani, L ;
Cianchi, A ;
Orlandi, G ;
Geitz, M .
PHYSICAL REVIEW E, 2001, 63 (05) :565011-565018
[3]  
DOBROVOLSKY SN, 2002, P EPAC 2002 PAR FRAN
[4]  
HANKE K, 1996, CLIC NOTE, V298
[5]   Measurement of the angular characteristics of transition radiation in near and far zones [J].
Kalinin, B. N. ;
Naumenko, G. A. ;
Potylitsyn, A. P. ;
Saruev, G. A. ;
Sukhikh, L. G. ;
Cha, V. A. .
JETP LETTERS, 2006, 84 (03) :110-114
[6]  
KALININ BN, 2006, IN PRESS NULC INST B
[7]   OBSERVATION OF COHERENT DIFFRACTION RADIATION FROM BUNCHED ELECTRONS PASSING THROUGH A CIRCULAR APERTURE IN THE MILLIMETER-WAVELENGTH AND SUBMILLIMETER-WAVELENGTH REGIONS [J].
SHIBATA, Y ;
HASEBE, S ;
ISHI, K ;
TAKAHASHI, T ;
OHSAKA, T ;
IKEZAWA, M ;
NAKAZATO, T ;
OYAMADA, M ;
URASAWA, S ;
YAMAKAWA, T ;
KONDO, Y .
PHYSICAL REVIEW E, 1995, 52 (06) :6787-6794
[8]  
TERMIKAELIAN ML, 1971, HIGH ENERGY ELECTROM, pCH4
[9]   Transition radiation in the pre-wave zone [J].
Verzilov, VA .
PHYSICS LETTERS A, 2000, 273 (1-2) :135-140
[10]   Overall comparison of subpicosecond electron beam diagnostics by the polychromator, the interferometer and the femtosecond streak camera [J].
Watanabe, T ;
Sugahara, J ;
Yoshimatsu, T ;
Sasaki, S ;
Sugiyama, Y ;
Ishi, K ;
Shibata, Y ;
Kondo, Y ;
Yoshii, K ;
Ueda, T ;
Uesaka, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 480 (2-3) :315-327