A systematic investigation of sample diluents in modern supercritical fluid chromatography

被引:67
作者
Desfontaine, Vincent [1 ]
Tarafder, Abhijit [2 ]
Hill, Jason [2 ]
Fairchild, Jacob [2 ]
Perrenoud, Alexandre Grand -Guillaume [1 ]
Veuthey, Jean-Luc [1 ]
Guillarme, Davy [1 ]
机构
[1] Univ Lausanne, Univ Geneva, Sch Pharmaceut Sci, CMU Rue Michel Servet 1, CH-1211 Geneva 4, Switzerland
[2] Waters Corp, 34 Maple St, Milford, MA 01757 USA
关键词
Supercritical fluid chromatography; Sample diluent; Peak shape; UHPSFC; Injection; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLAR STATIONARY PHASES; MU-M PARTICLES; PHARMACEUTICAL COMPOUNDS; MOBILE-PHASE; COSOLVENT ADSORPTION; INJECTION SOLVENTS; PEAK DEFORMATIONS; COLUMNS; SFC;
D O I
10.1016/j.chroma.2017.06.075
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper focuses on the possibility to inject large volumes (up to 10 mu L) in ultra-high performance supercritical fluid chromatography (UHPSFC) under generic gradient conditions. Several injection and method parameters have been individually evaluated (i.e. analyte concentration, injection volume, initial percentage of co-solvent in the gradient, nature of the weak needle wash solvent, nature of the sample diluent, nature of the column and of the analyte). The most critical parameters were further investigated using in a multivariate approach. The overall results suggested that several aprotic solvents including methyl tert-butyl ether (MTBE), dichloromethane, acetonitrile or cyclopentyl methyl ether (CPME) were well adapted for the injection of large volume in UHPSFC, while MeOH was generally the worst alternative. However, the nature of the stationary phase also had a strong impact and some of these diluents did not perform equally on each column. This was due to the existence of a competition in the adsorption of the analyte and the diluent on the stationary phase. This observation introduced the idea that the sample diluent should not only be chosen according to the analyte but also to the column chemistry to limit the interactions between the diluent and the ligands. Other important characteristics of the "ideal" SFC sample diluent were finally highlighted. Aprotic solvents with low viscosity are preferable to avoid strong solvent effects and viscous fingering, respectively. In the end, the authors suggest that the choice of the sample diluent should be part of the method development, as a function of the analyte and the selected stationary phase. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:122 / 131
页数:10
相关论文
共 40 条
[1]   Impact of injection solvents on supercritical fluid chromatography [J].
Abrahamsson, Victor ;
Sandahl, Margareta .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1306 :80-88
[2]  
Alsehli B, 2012, LC GC EUR, V25, P564
[3]   Demonstration of High Speeds with Low Pressure Drops Using 1.8 μm Particles in SFC [J].
Berger, Terry A. .
CHROMATOGRAPHIA, 2010, 72 (7-8) :597-602
[4]   Peak distortions arising from large-volume injections in supercritical fluid chromatography [J].
Dai, Yun ;
Li, Geng ;
Rajendran, Arvind .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1392 :91-99
[5]   Effects of large volume injection of aliphatic alcohols as sample diluents on the retention of low hydrophobic solutes in reversed-phase liquid chromatography [J].
David, Victor ;
Galaon, Toma ;
Aboul-Enein, Hassan Y. .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1323 :115-122
[6]   Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine [J].
Desfontaine, Vincent ;
Novakova, Lucie ;
Ponzetto, Federico ;
Nicoli, Raul ;
Saugy, Martial ;
Veuthey, Jean-Luc ;
Guillarme, Davy .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1451 :145-155
[7]   Evaluation of innovative stationary phase ligand chemistries and analytical conditions for the analysis of basic drugs by supercritical fluid chromatography [J].
Desfontaine, Vincent ;
Veuthey, Jean-Luc ;
Guillarme, Davy .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1438 :244-253
[8]   Supercritical fluid chromatography in pharmaceutical analysis [J].
Desfontaine, Vincent ;
Guillarme, Davy ;
Francotte, Eric ;
Novakova, Lucie .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 113 :56-71
[9]   A closer study of peak distortions in supercritical fluid chromatography as generated by the injection [J].
Enmark, Martin ;
Asberg, Dennis ;
Shalliker, Andrew ;
Samuelsson, Jorgen ;
Fornstedt, Torgny .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1400 :131-139
[10]  
Fairchild JN, 2013, LC GC N AM, V31, P326