Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum

被引:16
作者
Zlicar, Marko [1 ]
Novak-Jankovic, Vesna [1 ]
Blagus, Rok [2 ]
Cecconi, Maurizio [3 ]
机构
[1] Univ Med Ctr Ljubljana, Clin Dept Anaesthesiol & Intens Therapy, Zaloska 2, Ljubljana, Slovenia
[2] Univ Ljubljana, Med Fac, Inst Biostat & Med Informat, Vrazov Trg 2, Ljubljana, Slovenia
[3] St Georges Healthcare NHS Trust, Adult Crit Care, London SW17 0QT, England
关键词
Fluid responsiveness; Haemodynamics; Pneumoperitoneum; Dynamic predictors; CARDIAC-OUTPUT MEASUREMENT; ESOPHAGEAL DOPPLER; HYDROXYETHYL STARCH; ENHANCED-RECOVERY; OUTCOMES; SURGERY; THERAPY; POWER; OPTIMIZATION; METAANALYSIS;
D O I
10.1007/s10877-017-0081-4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Animal studies suggest that dynamic predictors remain useful in patients with pneumoperitoneum, but human data is conflicting. Our aim was to determine predictive values of pulse pressure variation (PPV) and stroke volume variation (SVV) in patients with pneumoperitoneum using LiDCORapid (TM) haemodynamic monitor. Standardised fluid challenges of colloid were administered to patients undergoing laparoscopic procedures, one fluid challenge per patient. Intra-abdominal pressure was automatically held at 12 mmHg Fluid responsiveness was defined as an increase in nominal stroke index (nSI)>= 10%. Linear regression was used to assess the ability of PPV and SVV to track the changes of nSI and logistic regression and area under the receiver operating curve (AUROC) to assess the predictive value of PPV and SVV for fluid responsiveness. Threshold values for PPV and SVV were obtained using the "gray zone" approach. A p < 0.05 was considered as statistically significant. 56 patients were included in analysis. 41 patients (73%) responded to fluids. Both PPV and SVV tracked changes in nSI (Spearman correlation coefficients 0.34 for PPV and 0.53 for SVV). Odds ratio for fluid responsiveness for PPV was 1.163 (95% CI 1.01-1.34) and for SVV 1.341 (95% CI 1.10-1.63). PPV achieved an AUROC of 0.674 (95% CI 0.518-0.830) and SVV 0.80 (95% CI 0.668-0.932). The gray zone of PPV ranged between 6.5 and 20.5% and that of SVV between 7.5 and 13%. During pneumoperitoneum, as measured by LiDCORapid (TM), PPV and SVV can predict fluid responsiveness, however their sensitivity is lower than the one reported in conditions without pneumoperitoneum.
引用
收藏
页码:825 / 832
页数:8
相关论文
共 56 条
[1]   Cardiac function during intraperitoneal CO2 insufflation for aortic surgery:: A transesophageal echocardiographic study [J].
Alfonsi, P ;
Vieillard-Baron, T ;
Coggia, M ;
Guignard, B ;
Goeau-Brissonniere, O ;
Jardin, F ;
Chauvin, M .
ANESTHESIA AND ANALGESIA, 2006, 102 (05) :1304-1310
[2]   Towards individualized perioperative, goal-directed haemodynamic algorithms for patients of advanced age: observations during a randomized controlled trial (NCT01141894) [J].
Bartha, E. ;
Arfwedson, C. ;
Imnell, A. ;
Kalman, S. .
BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (04) :486-492
[3]   Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid Responsiveness A "Gray Zone" Approach [J].
Cannesson, Maxime ;
Le Manach, Yannick ;
Hofer, Christoph K. ;
Goarin, Jean Pierre ;
Lehot, Jean-Jacques ;
Vallet, Benoit ;
Tavernier, Benoit .
ANESTHESIOLOGY, 2011, 115 (02) :231-241
[4]  
Cecconi M, 2012, MINERVA ANESTESIOL, V78, P527
[5]   Clinical review: Goal-directed therapy - what is the evidence in surgical patients? The effect on different risk groups [J].
Cecconi, Maurizio ;
Corredor, Carlos ;
Arulkumaran, Nishkantha ;
Abuella, Gihan ;
Ball, Jonathan ;
Grounds, R. Michael ;
Hamilton, Mark ;
Rhodes, Andrew .
CRITICAL CARE, 2013, 17 (02) :209
[6]   Predicting Fluid Responsiveness by Passive Leg Raising: A Systematic Review and Meta-Analysis of 23 Clinical Trials [J].
Cherpanath, Thomas G. V. ;
Hirsch, Alexander ;
Geerts, Bart F. ;
Lagrand, Wim K. ;
Leeflang, Mariska M. ;
Schultz, Marcus J. ;
Groeneveld, A. B. Johan .
CRITICAL CARE MEDICINE, 2016, 44 (05) :981-991
[7]   Continuous and intermittent cardiac output measurement in hyperdynamic conditions: pulmonary artery catheter vs. lithium dilution technique [J].
Costa, Maria Gabriella ;
Della Rocca, Giorgio ;
Chiarandini, Paolo ;
Mattelig, Silvia ;
Pompei, Livia ;
Barriga, Mauricio Sainz ;
Reynolds, Toby ;
Cecconi, Maurizio ;
Pietropaoli, Paolo .
INTENSIVE CARE MEDICINE, 2008, 34 (02) :257-263
[8]   Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery [J].
Derichard, A. ;
Robin, E. ;
Tavernier, B. ;
Costecalde, M. ;
Fleyfel, M. ;
Onimus, J. ;
Lebuffe, G. ;
Chambon, J. -P. ;
Vallet, B. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (05) :678-684
[9]   Reliability of continuous cardiac output measurement during intra-abdominal hypertension relies on repeated calibrations: an experimental animal study [J].
Gruenewald, Matthias ;
Renner, Jochen ;
Meybohm, Patrick ;
Hoecker, Jan ;
Scholz, Jens ;
Bein, Berthold .
CRITICAL CARE, 2008, 12 (05)
[10]   Respiratory stroke volume variation assessed by oesophageal Doppler monitoring predicts fluid responsiveness during laparoscopy [J].
Guinot, P. -G. ;
de Broca, B. ;
Bernard, E. ;
Abou Arab, O. ;
Lorne, E. ;
Dupont, H. .
BRITISH JOURNAL OF ANAESTHESIA, 2014, 112 (04) :660-664