Cardiac output measurement by transpulmonary versus conventional thermodilution technique in intensive care patients after coronary artery bypass grafting

被引:24
作者
Gust, R [1 ]
Gottschalk, A [1 ]
Bauer, H [1 ]
Bottiger, BW [1 ]
Bohrer, H [1 ]
Martin, E [1 ]
机构
[1] Heidelberg Univ, Dept Anesthesia, D-69120 Heidelberg, Germany
关键词
cardiac output; transpulmonary thermodilution; intensive care unit; weaning;
D O I
10.1016/S1053-0770(98)90093-3
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: The aim of the present study was to evaluate the correlation, accuracy, and precision of transpulmonary thermodilution cardiac output (CO) measurement. For this purpose, this technique was compared with the clinical gold standard, the CO measurement by pulmonary artery catheter in patients after coronary artery bypass grafting (CABG). Design: A prospective clinical study. Setting: A university medical center. Participants: Seventy-five patients in an intensive care unit (ICU) after CABG. Interventions: Standard (SCO) and transpulmonary thermodilution CO measurement (TPCO) measurements were simultaneously performed in triplicate by central venous injection of cooled saline solution. AII variables were recorded at five different time points of measurement during weaning from mechanical ventilation. Measurements and Main Results: CO measurements yielded 375 data pairs. SCO ranged from 2.0 to 10.2 L/min, and TPCO from 1.3 to 10.6 L/min. During the entire observation period, TPCO measurements tended to yield relatively high values, whereas SCO measurements resulted in lower values. Correlation between TPCO and SCO measurements was significant (r = 0.73; p < 0.05), accompanied by an accuracy with a bias of 0.456 L/min (7.3%) and a precision of 1.156 L/min (18.5%). Conclusion: In most patients, TPCO measurement will not replace the conventional technique by pulmonary artery catheter, but in some patients it offers an attractive, reliable, and safe method to determine CO. Copyright (C) 1998 by W.B. Saunders Company.
引用
收藏
页码:519 / 522
页数:4
相关论文
共 21 条
  • [1] EFFECTS OF THE RESPIRATORY CYCLE ON CARDIAC-OUTPUT MEASUREMENTS - REPRODUCIBILITY OF DATA ENHANCED BY TIMING THE THERMODILUTION INJECTIONS IN DOGS
    ARMENGOL, J
    MAN, GCW
    BALSYS, AJ
    WELLS, AL
    [J]. CRITICAL CARE MEDICINE, 1981, 9 (12) : 852 - 854
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] THERMAL RECOVERY AFTER PASSAGE OF THE PULMONARY CIRCULATION ASSESSED BY DECONVOLUTION
    BOCK, J
    DEUFLHARD, P
    HOEFT, A
    KORB, H
    WOLPERS, HG
    STEINMANN, J
    HELLIGE, G
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (03) : 1210 - 1216
  • [4] DAVIS R F, 1992, Anesthesiology (Hagerstown), V77, pA477
  • [5] SEMINAR ON CLINICAL APPLICATION OF TECHNIQUES TO MEASURE BLOOD-FLOW IN MAN .2. MEASUREMENT OF BLOOD-FLOW BY THERMODILUTION
    GANZ, W
    SWAN, HJC
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1972, 29 (02) : 241 - +
  • [6] THORACIC INTRAVASCULAR AND EXTRAVASCULAR FLUID VOLUMES IN CARDIAC SURGICAL PATIENTS
    HACHENBERG, T
    TENLING, A
    ROTHEN, HU
    NYSTROM, SO
    TYDEN, H
    HEDENSTIERNA, G
    [J]. ANESTHESIOLOGY, 1993, 79 (05) : 976 - 984
  • [7] HAMILTON WF, 1984, AM J PHYSIOL, V28, P338
  • [8] BEDSIDE ASSESSMENT OF INTRAVASCULAR VOLUME STATUS IN PATIENTS UNDERGOING CORONARY-BYPASS SURGERY
    HOEFT, A
    SCHORN, B
    WEYLAND, A
    SCHOLZ, M
    BUHRE, W
    STEPANEK, E
    ALLEN, SJ
    SONNTAG, H
    [J]. ANESTHESIOLOGY, 1994, 81 (01) : 76 - 86
  • [9] Hoeft A., 1995, YB INTENSIVE CARE EM, P593
  • [10] ACCURACY AND REPRODUCIBILITY OF THE MEASUREMENT OF ACTIVELY CIRCULATING BLOOD-VOLUME WITH AN INTEGRATED FIBEROPTIC MONITORING-SYSTEM
    KISCH, H
    LEUCHT, S
    LICHTWARCKASCHOFF, M
    PFEIFFER, UJ
    [J]. CRITICAL CARE MEDICINE, 1995, 23 (05) : 885 - 893