Corona Discharge Characteristics under Variable Frequency and Pressure Environments

被引:18
作者
Bas-Calopa, Pau [1 ]
Riba, Jordi-Roger [1 ]
Moreno-Eguilaz, Manuel [1 ]
机构
[1] Univ Politecn Cataluna, Dept Elect Engn, Terrassa 08222, Spain
关键词
more electric aircraft; electrical discharges; visual corona; corona extinction voltage; variable frequency; low pressure; TRACKING FAILURE; ARC TRACKING; AIRCRAFT; VOLTAGES; CABLES;
D O I
10.3390/s21196676
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
More electric aircrafts (MEAs) are paving the path to all electric aircrafts (AEAs), which make a much more intensive use of electrical power than conventional aircrafts. Due to the strict weight requirements, both MEA and AEA systems require to increase the distribution voltage in order to limit the required electrical current. Under this paradigm new issues arise, in part due to the voltage rise and in part because of the harsh environments found in aircrafts systems, especially those related to low pressure and high-electric frequency operation. Increased voltage levels, high-operating frequencies, low-pressure environments and reduced distances between wires pose insulation systems at risk, so partial discharges (PDs) and electrical breakdown are more likely to occur. This paper performs an experimental analysis of the effect of low-pressure environments and high-operating frequencies on the visual corona voltage, since corona discharges occurrence is directly related to arc tracking and insulation degradation in wiring systems. To this end, a rod-to-plane electrode configuration is tested in the 20-100 kPa and 50-1000 Hz ranges, these ranges cover most aircraft applications, so that the corona extinction voltage is experimentally determined by using a low-cost high-resolution CMOS imaging sensor which is sensitive to the visible and near ultraviolet (UV) spectra. The imaging sensor locates the discharge points and the intensity of the discharge, offering simplicity and low-cost measurements with high sensitivity. Moreover, to assess the performance of such sensor, the discharges are also acquired by analyzing the leakage current using an inexpensive resistor and a fast oscilloscope. The experimental data presented in this paper can be useful in designing insulation systems for MEA and AEA applications.
引用
收藏
页数:13
相关论文
共 43 条
[1]  
Andrea J, 2017, ELECTR CONTACT, P317, DOI 10.1109/HOLM.2017.8088106
[2]  
[Anonymous], 2017, STUDY ELECT ARC IGNI
[3]  
[Anonymous], 2018, India-Thailand joint call for proposals
[4]  
BABRAUSKAS V, 2008, 9 INT S FIR SAF SCI, P3
[5]   Characterization of Partial Discharge Activities in WBG Power Converters under Low-Pressure Condition [J].
Borghei, Moein ;
Ghassemi, Mona .
ENERGIES, 2021, 14 (17)
[6]   Insulation Materials and Systems for More- and All-Electric Aircraft: A Review Identifying Challenges and Future Research Needs [J].
Borghei, Moein ;
Ghassemi, Mona .
IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2021, 7 (03) :1930-1953
[7]   Positive streamers in air and nitrogen of varying density: experiments on similarity laws [J].
Briels, T. M. P. ;
van Veldhuizen, E. M. ;
Ebert, U. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2008, 41 (23)
[8]   Partial discharge, testing of solder fillets on PCBs in a partial vacuum: New experimental results [J].
Capineri, L ;
Dainelli, G ;
Materassi, M ;
Dunn, BD .
IEEE TRANSACTIONS ON ELECTRONICS PACKAGING MANUFACTURING, 2003, 26 (04) :294-304
[9]  
Cella B., 2015, ON LINE PARTIAL DISC
[10]   Application of UHF Sensors in Power System Equipment for Partial Discharge Detection: A Review [J].
Chai, Hua ;
Phung, B. T. ;
Mitchell, Steve .
SENSORS, 2019, 19 (05)