Diagnostic Value of Contrast-Enhanced Ultrasound for Evaluation of Transjugular Intrahepatic Portosystemic Shunt Perfusion

被引:7
作者
Marschner, Constantin A. [1 ]
Geyer, Thomas [1 ]
Froelich, Matthias F. [2 ]
Ruebenthaler, Johannes [1 ]
Schwarze, Vincent [1 ]
Clevert, Dirk-Andre [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Radiol, Univ Hosp, D-81377 Munich, Germany
[2] Univ Med Ctr Mannheim, Dept Clin Radiol & Nucl Med, D-68167 Mannheim, Germany
关键词
contrast-enhanced ultrasound; transjugular intrahepatic portosystemic shunt; color doppler ultrasound; computed tomography; magnetic resonance tomography; COVERED STENT-GRAFTS; CT-ANGIOGRAPHY; DOPPLER-ULTRASONOGRAPHY; PORTAL-HYPERTENSION; TIPS; CEUS; DYSFUNCTION; MANAGEMENT; CIRRHOSIS; PATENCY;
D O I
10.3390/diagnostics11091593
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In patients with liver cirrhosis, transjugular intrahepatic portosystemic shunt (TIPS) displays an effective method for treating portal hypertension. Main indications include refractory ascites and secondary prevention of esophageal bleeding. Color Doppler ultrasound (CDUS) plays a leading role in the follow-up management, whereas contrast-enhanced ultrasound (CEUS) is not routinely considered. We compared the efficacy of CEUS to CDUS and highlighted differences compared to findings of corresponding computed tomography (CT) and magnetic resonance imaging (MRI). (2) Methods: On a retrospective basis, 106 patients with CEUS examination after TIPS were included. The enrollment period was 12 years (between 2008 and 2020) and the age group ranged from 23.3 to 82.1 years. In addition, 92 CDUS, 43 CT and 58 MRI scans were evaluated for intermodal comparison. (3) Results: Intermodal analysis and comparison revealed a high level of concordance between CDUS, CT and MRI in the vast majority of cases. In comparison to CDUS, the correlation of the relevant findings was 92.5%, 95.3% for CT and 87.9% for MRI. In some cases, however, additional information was provided by CEUS (4) Conclusions: CEUS depicts a safe and effective imaging modality for follow-up after TIPS. In addition to CDUS, CEUS enables specific assessment of stent pathologies and stent dysfunction due to its capacity to dynamically visualize single microbubbles at high spatial and temporal resolution. Due to the low number of adverse events regarding the application of contrast agents, CEUS can be administered to a very broad patient population, thus avoiding additional radiation exposure compared to CT angiography in cases with divergent findings during follow-up.
引用
收藏
页数:13
相关论文
共 46 条
  • [1] Utility of color Doppler ultrasonography predicting TIPS dysfunction
    Abraldes, JG
    Gilabert, R
    Turnes, J
    Nicolau, C
    Berzigotti, A
    Aponte, J
    Bru, C
    Bosch, J
    García-Pagán, JC
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2005, 100 (12) : 2696 - 2701
  • [2] Polytetrafluoroethylene-covered stent grafts for TIPS procedure: 1-year patency and clinical results
    Angeloni, S
    Merli, M
    Salvatori, FM
    De Santis, A
    Fanelli, F
    Pepino, D
    Attili, AF
    Rossi, P
    Riggio, O
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2004, 99 (02) : 280 - 285
  • [3] Comparison of transjugular intrahepatic portosystemic shunt dysfunction in PTFE-covered stent-grafts versus bare stents
    Barrio, J
    Ripoll, C
    Bañares, R
    Echenagusia, A
    Catalina, MV
    Camúñez, F
    Simó, G
    Santos, L
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2005, 55 (01) : 120 - 124
  • [4] Role of Transjugular Intrahepatic Portosystemic Shunt (TIPS) in the Management of Portal Hypertension: Update 2009
    Boyer, Thomas D.
    Haskal, Ziv J.
    [J]. HEPATOLOGY, 2010, 51 (01) : 306 - 306
  • [5] Transjugular intrahepatic portosystemic shunts (TIPS) for the prevention of variceal re-bleeding - A two decades experience
    Bucsics, Theresa
    Schoder, Maria
    Diermayr, Magdalena
    Feldner-Busztin, Maria
    Goeschl, Nicolas
    Bauer, David
    Schwabl, Philipp
    Mandorfer, Mattias
    Angermayr, Bernhard
    Cejna, Manfred
    Ferlitsch, Arnulf
    Sieghart, Wolfgang
    Trauner, Michael
    Peck-Radosavljevic, Markus
    Karner, Josef
    Karnel, Franz
    Reiberger, Thomas
    [J]. PLOS ONE, 2018, 13 (01):
  • [6] EVAR: Benefits of CEUS for monitoring stent-graft status
    Cantisani, Vito
    Grazhdani, Hektor
    Clevert, Dirk-Andre
    Iezzi, Roberto
    Aiani, Luca
    Martegani, Alberto
    Fanelli, Fabrizio
    Di Marzo, Luca
    Wlderk, Andrea
    Cirelli, Carlo
    Catalano, Carlo
    Di Leo, Nicola
    Di Segni, Mattia
    Malpassini, Flavio
    D'Ambrosio, Ferdinando
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (09) : 1658 - 1665
  • [7] Role of ultrasound surveillance of transjugular intrahepatic portosystemic shunts in the covered stent era
    Carr, Caitlin E.
    Tuite, Catherine M.
    Soulen, Michael C.
    Shlansky-Goldberg, Richard D.
    Clark, Timothy W. I.
    Mondschein, Jeffrey I.
    Kwak, Andrew
    Patel, Aalpen A.
    Coleman, Beverly G.
    Trerotola, Scott O.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (08) : 1297 - 1305
  • [8] Alteration of contrast enhanced ultrasound (CEUS) of hepatocellular carcinoma in patients with cirrhosis and transjugular intrahepatic portosystemic shunt (TIPS)
    Chang, Johannes
    Dumitrache, Alexia
    Boehling, Nina
    Abu-Omar, Jasmin
    Meyer, Carsten
    Strobel, Deike
    Luetkens, Julian
    Luu, Andreas Minh
    Rockstroh, Juergen
    Strassburg, Christian P.
    Trebicka, Jonel
    Gonzalez-Carmona, Maria A.
    Marinova, Milka
    Praktiknjo, Michael
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [9] Transjugular intrahepatic portal shunt in the treatment of portal hypertension due to cirrhosis: single center experience
    Chen, Yun
    Qiu, Hanyu
    Zhang, Xiaomei
    [J]. BMC SURGERY, 2019, 19 (01)
  • [10] COLAPINTO RF, 1982, CAN MED ASSOC J, V126, P267