Evaluation of a tapered polymer-free sirolimus-eluting stent in porcine coronary arteries

被引:0
|
作者
Shi, Qiu-Ping [1 ]
Zheng, Bo [1 ]
Chen, Ming [1 ]
Wang, Xin-Gang [1 ]
Zhang, Bin [1 ]
机构
[1] Peking Univ, Dept Cardiol, Hosp 1, 8 Xishiku St, Beijing 100034, Peoples R China
来源
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE | 2016年 / 9卷 / 03期
关键词
Polymer-free; drug eluting stent; porcine coronary model; tapered stent; DIFFERENT COATING STRATEGIES; BARE METAL STENTS; RANDOMIZED-TRIAL; FOLLOW-UP; COMPLEX LESIONS; TAXUS-II; RESTENOSIS; LONG; MODEL; BALLOON;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: No stent is yet available for tapering coronary arteries. The purpose of the present study is to evaluate the applicability, efficacy and safety of a novel tapered, polymer-free sirolimus eluting stent (t-PFSES) specifically designed for tapering coronary arteries. Methods: 28 pigs underwent the placement of 56 oversized stents (control, n = 28, t-PFSES, n = 28), and quantitative coronary angiography (QCA) and histopathologic analysis were performed at 1, 3 and 6 months follow-up. Results: In proximal segments, both the t-PFSES and control stents lead to similar results, while, in distal segments, the t-PFSES stent was associated with significantly improved angiographic outcomes. Compared with the control stents, t-PFSES exhibited a greater inhibition of neointimal hyperplasia in all stented segments, but the magnitude of the neointimal area was lower in the proximal segments than in the distal segments, (1.15 vs. 1.48 mm(2), 0.33 vs. 0.8 mm(2), 0.3 vs. 1.14 mm(2) at 1, 3 and 6 months, respectively, P > 0.05). Complete re-endothelialization was observed with both stents at 1 month post-procedure, but the t-PFSES stented distal segments had numerically lower inflammation scores (P = NS). Conclusion: The t-PFSES stent is applicable to coronary artery segments with marked tapering (10% tapering or 0.45 mm). Compared with the conventional bare metal stent, t-PFSES appeared to be safer and lead to superior angiographic outcomes, especially in the distal segments of tapering coronary arteries.
引用
收藏
页码:5379 / 5388
页数:10
相关论文
共 50 条
  • [11] Sirolimus-eluting coronary stent
    Vishnevetsky, D
    Patel, P
    Tijerino, H
    Gandhi, PJ
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2004, 61 (05) : 449 - 456
  • [12] The overlap nano-porous polymer-free sirolimus-eluting stent in swine model evaluated by optical coherence tomography and histopathology
    Zheng, Bo
    Hou, Chang
    Wang, Xingang
    Zhang, Bin
    Shi, Qiuping
    Chen, Ming
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (06): : 11220 - 11227
  • [13] A new polymer-free drug-eluting stent with nanocarriers eluting sirolimus from stent-plus-balloon compared with bare-metal stent and with biolimus A9 eluting stent in porcine coronary arteries
    Takimura, Celso K.
    Galon, Micheli Z.
    Gutierrez, Paulo S.
    Sojitra, Prakash
    Vyas, Ashwin
    Doshi, Manish
    Lemos, Pedro A.
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2015, 5 (02) : 113 - 121
  • [14] Randomized Comparison of a Polymer-Free Sirolimus-Eluting Stent Versus a Polymer-Based Paclitaxel-Eluting Stent in Patients With Diabetes Mellitus The LIPSIA Yukon Trial
    Desch, Steffen
    Schloma, Denis
    Moebius-Winkler, Sven
    Erbs, Sandra
    Gielen, Stephan
    Linke, Axel
    Yu, Jiangtao
    Lauer, Bernward
    Kleinertz, Klaus
    Daenschel, Wilfried
    Schuler, Gerhard
    Thiele, Holger
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (04) : 452 - 459
  • [15] Real-World Dual Antiplatelet Therapy Following Polymer-Free Sirolimus-Eluting Stent Implantations to Treat Coronary Artery Disease
    Florian Krackhardt
    Matthias Waliszewski
    Viktor Kočka
    Petr Toušek
    Bronislav Janek
    Martin Hudec
    Fernando Lozano
    Koldobika Garcia-San Roman
    Bruno Garcia del Blanco
    Josepa Mauri
    Tay Mok Heang
    Tae Hoon Ahn
    Myung Ho Jeong
    Denny Herberger
    Vjekoslav Tomulic
    Gilles Levy
    Laurent Sebagh
    Jérôme Rischner
    Michel Pansieri
    Cardiovascular Drugs and Therapy, 2020, 34 : 335 - 344
  • [16] 1-Year Results of the Hydroxyapatite Polymer-Free Sirolimus-Eluting Stent for the Treatment of Single De Novo Coronary Lesions The VESTASYNC I Trial
    Costa, J. Ribamar, Jr.
    Abizaid, Alexandre
    Costa, Ricardo
    Feres, Fausto
    Tanajura, Luiz Fernando
    Abizaid, Andrea
    Maldonado, Galo
    Staico, Rodolfo
    Siqueira, Dimytri
    Sousa, Amanda G. M. R.
    Bonan, Raoul
    Sousa, J. Eduardo
    JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (05) : 422 - 427
  • [17] Nine-month angiographic and two-year clinical follow-up of polymer-free sirolimus-eluting stent versus durable-polymer sirolimus-eluting stent for coronary artery disease: the Nano randomized trial
    Zhang Yaojun
    Chen Fang
    Muramatsu, Takashi
    Xu Bo
    Li Zhanquan
    Ge Junbo
    He Qing
    Yang Zhijian
    Li Shumei
    Wang Lefeng
    Wang Haichang
    He Ben
    Li Kang
    Qi Guoxian
    Li Tianchang
    Zeng Hesong
    Peng Jianjun
    Jiang Tieming
    Zeng Qiutang
    Zhu Jianhua
    Fu Guosheng
    Bourantas, Christos V.
    Serruys, Patrick W.
    Huo Yong
    CHINESE MEDICAL JOURNAL, 2014, 127 (11) : 2153 - 2158
  • [18] Real-World Dual Antiplatelet Therapy Following Polymer-Free Sirolimus-Eluting Stent Implantations to Treat Coronary Artery Disease
    Krackhardt, Florian
    Waliszewski, Matthias
    Kocka, Viktor
    Tousek, Petr
    Janek, Bronislav
    Hudec, Martin
    Lozano, Fernando
    Roman, Koldobika Garcia-San
    del Blanco, Bruno Garcia
    Mauri, Josepa
    Heang, Tay Mok
    Ahn, Tae Hoon
    Jeong, Myung Ho
    Herberger, Denny
    Tomulic, Vjekoslav
    Levy, Gilles
    Sebagh, Laurent
    Rischner, Jerome
    Pansieri, Michel
    CARDIOVASCULAR DRUGS AND THERAPY, 2020, 34 (03) : 335 - 344
  • [19] Safety and efficacy of cobalt chromium alloy based sirolimus-eluting stent with bioabsorbable polymer in porcine model
    Wu Yi-zhe
    Shen Li
    Wang Qi-bing
    Hu Xi
    Xie Jian
    Qian Ju-ying
    Ge Jun-bo
    CHINESE MEDICAL JOURNAL, 2012, 125 (06) : 983 - 989
  • [20] Comparison the long-term clinical outcomes of Nano polymer-free sirolimus-eluting stent versus Endeavor durable polymer zotarolimus-eluting stent in patients with acute coronary syndrome
    文明洪
    刘松
    纪阳
    韩兆帅
    South China Journal of Cardiology, 2016, 17 (03) : 139 - 146