How sensitive is the deltoid moment arm to humeral offset changes with reverse total shoulder arthroplasty?

被引:17
|
作者
Walker, David R. [1 ]
Kinney, Allison L. [2 ]
Wright, Thomas W. [3 ]
Banks, Scott A. [1 ]
机构
[1] Univ Florida, Dept Mech Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL USA
[3] Univ Florida, Orthopaed & Sports Med Inst, 3450 Hull Rd, Gainesville, FL 32611 USA
关键词
Deltoid components; deltoid muscle; humeral offset; joint center; muscle moment arm; reverse total shoulder arthroplasty; PROSTHESIS; IMPINGEMENT; REPLACEMENT; ARTHRITIS; ROTATION; MOTION; RANGE;
D O I
10.1016/j.jse.2015.10.028
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Reverse total shoulder arthroplasty commonly treats cuff-deficient or osteoarthritic shoulders not amenable to rotator cuff repair. This study investigates deltoid moment arm sensitivity to variations in the joint center and humeral offset of 3 representative reverse total shoulder arthroplasty subjects. We hypothesized that a superior joint implant placement may exist, indicated by muscle moment arms, compared with the current actual surgical implant configuration. Methods: Moment arms for the anterior, lateral, and posterior aspects of the deltoid muscle were determined for 1521 perturbations of the humeral offset location away from the surgical placement in a subject-specific musculoskeletal model with motion defined by subject-specific in vivo abduction kinematics. The humeral offset was varied from its surgical position +/- 4 mm in the anterior/posterior direction, +/- 12 mm in the medial/lateral direction, and -10 to 14 mm in the superior/inferior direction. Results: The anterior deltoid moment arm varied in humeral offset and center of rotation up to 20 mm, primarily in the medial/lateral and superior/inferior directions. The lateral deltoid moment arm varied in humeral offset up to 20 mm, primarily in the medial/lateral and anterior/posterior directions. The posterior deltoid moment arm varied up to 15 mm, primarily in early abduction, and was most sensitive to humeral offset changes in the superior/inferior direction. Discussion: High variations in muscle moment arms were found for all 3 deltoid components, presenting an opportunity to dramatically change the deltoid moment arms through surgical placement of the reverse shoulder components and by varying the overall offset of the humerus. (C) 2016 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:998 / 1004
页数:7
相关论文
共 50 条
  • [21] Reverse total shoulder arthroplasty with combined deltoid reconstruction in patients with anterior and/or middle deltoid tears
    Marinello, Patrick G.
    Amini, Michael H.
    Peers, Sebastian
    O'Donnell, Jeffrey
    Iannotti, Joseph P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (06) : 936 - 941
  • [22] Does glenohumeral offset affect clinical outcomes in a lateralized reverse total shoulder arthroplasty?
    Wolf, G. Jacob
    Reid, Jared J.
    Rabinowitz, Justin R.
    Barcel, D. Anthony
    Barfield, William R.
    Eichinger, Josef K.
    Friedman, Richard J.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (01) : 50 - 58
  • [23] Combined effect of change in humeral neck-shaft angle and retroversion on shoulder range of motion in reverse total shoulder arthroplasty - A simulation study
    Jeon, Byung-Kwan
    Panchal, Karnav A.
    Ji, Jong-Hun
    Xin, Yuan-Zhu
    Park, Sung-Ryeoll
    Kim, Joong-Hui
    Yang, Seok-Jo
    CLINICAL BIOMECHANICS, 2016, 31 : 12 - 19
  • [24] Hemiarthroplasty and Total Shoulder Arthroplasty Conversion to Reverse Total Shoulder Arthroplasty
    Harrison, Alicia K.
    Knudsen, Michael L.
    Braman, Jonathan P.
    CURRENT REVIEWS IN MUSCULOSKELETAL MEDICINE, 2020, 13 (04) : 501 - 508
  • [25] Posterior and inferior glenosphere position in reverse total shoulder arthroplasty supports deltoid efficiency for shoulder flexion and elevation
    Meisterhans, Michel
    Bouaicha, Samy
    Meyer, Dominik C.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (08) : 1515 - 1522
  • [26] Reverse total shoulder arthroplasty
    Scalise, J. J.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2009, 60 (01) : 53 - 59
  • [27] Implant Design Variations in Reverse Total Shoulder Arthroplasty Influence the Required Deltoid Force and Resultant Joint Load
    Giles, Joshua W.
    Langohr, Daniel G.
    Johnson, James A.
    Athwal, George S.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (11) : 3615 - 3626
  • [28] Contact mechanics of reverse total shoulder arthroplasty during abduction: the effect of neck-shaft angle, humeral cup depth, and glenosphere diameter
    Langohr, G. Daniel G.
    Willing, Ryan
    Medley, John B.
    Athwal, George S.
    Johnson, James A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (04) : 589 - 597
  • [29] Effect of humeral stem design on humeral position and range of motion in reverse shoulder arthroplasty
    Laedermann, Alexandre
    Denard, Patrick J.
    Boileau, Pascal
    Farron, Alain
    Deransart, Pierric
    Terrier, Alexandre
    Ston, Julien
    Walch, Gilles
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (11) : 2205 - 2213
  • [30] Kinematic analysis of dynamic shoulder motion in patients with reverse total shoulder arthroplasty
    Kwon, Young W.
    Pinto, Vivek J.
    Yoon, Jangwhon
    Frankle, Mark A.
    Dunning, Page E.
    Sheikhzadeh, Ali
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (09) : 1184 - 1190