Background: Reverse total shoulder arthroplasty commonly treats cuff-deficient or osteoarthritic shoulders not amenable to rotator cuff repair. This study investigates deltoid moment arm sensitivity to variations in the joint center and humeral offset of 3 representative reverse total shoulder arthroplasty subjects. We hypothesized that a superior joint implant placement may exist, indicated by muscle moment arms, compared with the current actual surgical implant configuration. Methods: Moment arms for the anterior, lateral, and posterior aspects of the deltoid muscle were determined for 1521 perturbations of the humeral offset location away from the surgical placement in a subject-specific musculoskeletal model with motion defined by subject-specific in vivo abduction kinematics. The humeral offset was varied from its surgical position +/- 4 mm in the anterior/posterior direction, +/- 12 mm in the medial/lateral direction, and -10 to 14 mm in the superior/inferior direction. Results: The anterior deltoid moment arm varied in humeral offset and center of rotation up to 20 mm, primarily in the medial/lateral and superior/inferior directions. The lateral deltoid moment arm varied in humeral offset up to 20 mm, primarily in the medial/lateral and anterior/posterior directions. The posterior deltoid moment arm varied up to 15 mm, primarily in early abduction, and was most sensitive to humeral offset changes in the superior/inferior direction. Discussion: High variations in muscle moment arms were found for all 3 deltoid components, presenting an opportunity to dramatically change the deltoid moment arms through surgical placement of the reverse shoulder components and by varying the overall offset of the humerus. (C) 2016 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:998 / 1004
页数:7
相关论文
共 50 条
  • [1] How do deltoid muscle moment arms change after reverse total shoulder arthroplasty?
    Walker, David R.
    Struk, Aimee M.
    Matsuki, Keisuke
    Wright, Thomas W.
    Banks, Scott A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (04) : 581 - 588
  • [2] Humeral offset as a predictor of outcomes after reverse shoulder arthroplasty
    Carrazana-Suarez, Luis F.
    Panico, Leighann C.
    Smolinski, Michael P.
    Blake, Ryan J.
    McCroskey, Miranda A.
    Sykes, Joshua B.
    Lin, Albert
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (06) : S158 - S165
  • [3] Humeral Stem Design in Reverse Total Shoulder Arthroplasty
    Lehman, Andrew C.
    Su, Favian
    Feeley, Brian T.
    CURRENT REVIEWS IN MUSCULOSKELETAL MEDICINE, 2024, 17 (12) : 616 - 624
  • [4] Biomechanical consequences of glenoid and humeral lateralization in reverse total shoulder arthroplasty
    Liu, Bei
    Kim, Young Kyu
    Nakla, Andrew
    Chung, Min-Shik
    Kwak, Daniel
    McGarry, Michelle H.
    Lee, Thay Q.
    Oh, Joo Han
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (08) : 1662 - 1672
  • [5] Humeral and Glenoid Version in Reverse Total Shoulder Arthroplasty: A Systematic Review
    Berton, Alessandra
    Longo, Umile Giuseppe
    Gulotta, Lawrence V.
    De Salvatore, Sergio
    Piergentili, Ilaria
    Calabrese, Giovanni
    Roberti, Federica
    Warren, Russell F.
    Denaro, Vincenzo
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (24)
  • [6] Reverse total shoulder arthroplasty: a biomechanical evaluation of humeral and glenosphere hardware configuration
    Tashjian, Robert Z.
    Burks, Robert T.
    Zhang, Yue
    Henninger, Heath B.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (03) : E68 - E77
  • [7] Effects of humeral component retroversion on functional outcomes in reverse total shoulder arthroplasty for cuff tear arthropathy
    Rhee, Yong Girl
    Cho, Nam Su
    Moon, Seong Cheol
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (10) : 1574 - 1581
  • [8] Humeral component retroversion in reverse total shoulder arthroplasty: a biomechanical study
    Gulotta, Lawrence V.
    Choi, Dan
    Marinello, Patrick
    Knutson, Zakary
    Lipman, Joseph
    Wright, Timothy
    Cordasco, Frank A.
    Craig, Edward V.
    Warren, Russell F.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (09) : 1121 - 1127
  • [9] Effect of deltoid tension and humeral version in reverse total shoulder arthroplasty: a biomechanical study
    Henninger, Heath B.
    Barg, Alexej
    Anderson, Andrew E.
    Bachus, Kent N.
    Tashjian, Robert Z.
    Burks, Robert T.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (04) : 483 - 490
  • [10] The Influence of Reverse Total Shoulder Arthroplasty Implant Design on Biomechanics
    Cogan, Charles J.
    Ho, Jason C.
    Entezari, Vahid
    Iannotti, Joseph P.
    Ricchetti, Eric T.
    CURRENT REVIEWS IN MUSCULOSKELETAL MEDICINE, 2023, 16 (03) : 95 - 102