Influence of Impeller Speed Patterns on Hemodynamic Characteristics and Hemolysis of the Blood Pump

被引:23
|
作者
Wang, Yiwen [1 ]
Shen, Peng [1 ]
Zheng, Minli [1 ]
Fu, Pengqiang [1 ]
Liu, Lijia [1 ]
Wang, Jingyue [1 ]
Yuan, Lishan [1 ]
机构
[1] Harbin Univ Sci & Technol, Minist Educ, Key Lab Adv Mfg & Intelligent Technol, Harbin 150080, Heilongjiang, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 21期
基金
中国国家自然科学基金;
关键词
blood pump; fluid simulation; hemodynamic characteristics; hemolysis; pulsation; speed patterns; VENTRICULAR ASSIST DEVICES; CONTINUOUS-FLOW; PULSATILE-FLOW; MODULATION; HEART;
D O I
10.3390/app9214689
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A continuous-flow output mode of a rotary blood pump reduces the fluctuation range of arterial blood pressure and easily causes complications. For a centrifugal rotary blood pump, sinusoidal and pulsatile speed patterns are designed using the impeller speed modulation. This study aimed to analyze the hemodynamic characteristics and hemolysis of different speed patterns of a blood pump in patients with heart failure using computational fluid dynamics (CFD) and the lumped parameter model (LPM). The results showed that the impeller with three speed patterns (including the constant speed pattern) met the normal blood demand of the human body. The pulsating flow generated by the impeller speed modulation effectively increased the maximum pulse pressure (PP) to 12.7 mm Hg, but the hemolysis index (HI) in the sinusoidal and pulsatile speed patterns was higher than that in the constant speed pattern, which was about 2.1 x 10(-5). The flow path of the pulsating flow field in the spiral groove of the hydrodynamic suspension bearing was uniform, but the alternating high shear stress (0 similar to 157 Pa) was caused by the impeller speed modulation, causing blood damage. Therefore, the rational modulation of the impeller speed and the structural optimization of a blood pump are important for improving hydrodynamic characteristics and hemolysis.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Influence of impeller design on hemolysis of an axial blood pump
    Liu, Lei
    Wang, Fangqun
    Wu, Qinlin
    Wu, Wenjue
    Qian, Kunxi
    Ji, Jinghua
    Zhao, Wenxiang
    He, Weixing
    Li, Tianbo
    MEDICAL MATERIALS AND ENGINEERING, 2012, 140 : 162 - 166
  • [2] Impact of Impeller Speed Adjustment Interval on Hemolysis Performance of an Intravascular Micro-Axial Blood Pump
    Liu, Yuan
    Zhu, Yuanfei
    Wang, Shangting
    Fu, Hualin
    Lu, Zhexin
    Yang, Ming
    MICROMACHINES, 2024, 15 (07)
  • [3] Numerical investigation of volute tongue design on hemodynamic characteristics and hemolysis of the centrifugal blood pump
    Ibrahim Basar Aka
    Caglar Ozturk
    Ismail Lazoglu
    SN Applied Sciences, 2021, 3
  • [4] Numerical hemolysis performance evaluation of a rotary blood pump under different speed modulation profiles
    Huang, Feng
    Lei, Huan
    Ying, Shunv
    Fu, Yang
    Li, Qipeng
    Ruan, Xiaodong
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [5] Relationship between pump speed design and hemolysis in an axial flow blood pump
    Anai, H
    Wakisaka, Y
    Nakatani, T
    Taenaka, Y
    Takano, H
    Hadama, T
    ARTIFICIAL ORGANS, 1996, 20 (06) : 564 - 567
  • [6] HYDRODYNAMIC AND HEMOLYSIS ANALYSIS ON DISTANCE AND CLEARANCE BETWEEN IMPELLER AND DIFFUSER OF AXIAL BLOOD PUMP
    Yu, Jiajia
    Zhang, Xiwen
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2016, 16 (02)
  • [7] The Influence of Impeller Geometries on Hemolysis in Bearingless Centrifugal Pumps
    Puentener, Pascal
    Schuck, Marcel
    Kolar, Johann W.
    IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY, 2020, 1 : 316 - 323
  • [8] Effect of Axial Flow Blood Pump's Pulsation Speed Regulation on Key Hemodynamic Parameters
    Wang, Shuai
    Wang, Hao
    Yu, Zheqin
    Tan, Jianping
    Li, Geqiang
    Guo, Bin
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2023, 23 (08)
  • [9] The Influence of Rotary Blood Pump Speed Modulation on the Risk of Intraventricular Thrombosis
    Liao, Sam
    Wu, Eric L.
    Neidlin, Michael
    Li, Zhiyong
    Simpson, Benjamin
    Gregory, Shaun D.
    ARTIFICIAL ORGANS, 2018, 42 (10) : 943 - 953
  • [10] Impeller (straight blade) design variations and their influence on the performance of a centrifugal blood pump
    Fang, Peng
    Du, Jianjun
    Yu, Shunzhou
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2020, 43 (12) : 782 - 795