The rein-type arthroscopic capsular suture for triangular fibrocartilage complex foveal tears: midterm results for 90 patients

被引:5
|
作者
Lo, I-Ning [1 ,2 ,3 ]
Chen, Kuan-Jung [1 ,2 ,3 ]
Huang, Tung-Fu [1 ,2 ,3 ]
Huang, Yi-Chao [1 ,2 ,3 ]
机构
[1] Taipei Vet Gen Hosp, Dept Orthoped & Traumatol, 201,Sec 2,Shi Pai Rd, Taipei 112, Taiwan
[2] Natl Yang Ming Chiao Tung Univ, Dept Orthopaed, Taipei, Taiwan
[3] Natl Yang Ming Univ, Dept Orthopaed, Taipei, Taiwan
关键词
Triangular fibro-cartilage complex (TFCC) tear; arthroscopic TFCC repair; foveal reattachment; distal radioulnar joint (DRUJ) stability; RADIOULNAR JOINT INSTABILITY; PERIPHERAL TEARS; ASSISTED REPAIR; CLASSIFICATION; MANAGEMENT; STABILITY; AVULSION; ANATOMY; WRIST;
D O I
10.1177/17531934211024177
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We describe an arthroscopic rein-type capsular suture that approximates the triangular fibrocartilage complex to the anatomical footprint, and report the results at a minimum 12 month follow-up. The procedure involves two 3-0 polydioxanone horizontal mattress sutures inserted 1.5 cm proximal to the 6-R and 6-U portals to obtain purchase on the dorsal and anterior radioulnar ligaments, respectively. The two sutures work as a rein to approximate the triangular fibrocartilage complex to the fovea. Ninety patients with Type IB triangular fibrocartilage complex injuries were included retrospectively. The 12-month postoperative Modified Mayo Wrist scores, Disabilities of Arm, Shoulder and Hand scores and visual analogue scale for pain showed significant improvements on preoperative values. Postoperative range of wrist motion, grip strength and ultrasound assessment of the distal radioulnar joint stability were comparable with the normal wrist. The patients had high satisfaction scores for surgery. There were minor complications of knot irritation. No revision surgery for distal radioulnar joint instability was required. It is an effective and technically simple procedure that provides a foveal footprint contact for the triangular fibrocartilage complex.
引用
收藏
页码:1049 / 1056
页数:8
相关论文
共 28 条
  • [1] Comparing the Outcomes of Suture Anchor Repair and Rein-Type Capsular Suture for Triangular Fibrocartilage Complex Foveal Tears With a Minimum 2-Year Follow-Up
    Lo, I-Ning
    Chen, Kuan-Jung
    Yin, Cheng-Yu
    Huang, Hui-Kuang
    Wang, Jung-Pan
    Huang, Yi-Chao
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2024, 49 (04): : 321 - 328
  • [2] Arthroscopic foveal repair with suture anchors for traumatic tears of the triangular fibrocartilage complex
    Yeh, Kuang-Ting
    Wu, Wen-Tien
    Wang, Jen-Hung
    Shih, Jui-Tien
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [3] Arthroscopic Capsular Repair for Triangular Fibrocartilage Complex Tears
    Takagi, Takehiko
    Nakamura, Toshiyasu
    Fukuoka, Masatoshi
    JOURNAL OF WRIST SURGERY, 2021, 10 (03) : 249 - 254
  • [4] Midterm Results after Open versus Arthroscopic Transosseous Repair for Foveal Tears of the Triangular Fibrocartilage Complex
    Abe, Yukio
    Fujii, Kenzo
    Fujisawa, Takeyoshi
    JOURNAL OF WRIST SURGERY, 2018, 7 (04) : 292 - 297
  • [5] Arthroscopic Transosseous Repair of Foveal Tears of the Triangular Fibrocartilage Complex: A Systematic Review of Clinical Outcomes
    Jung, Hyoung-Seok
    Kim, Seong Hwan
    Jung, Chan Woo
    Woo, Sung Jong
    Kim, Jong Pil
    Lee, Jae-Sung
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2021, 37 (05): : 1641 - 1650
  • [6] Relevant landmarks to navigate the suture locations for the arthroscopic triangular fibrocartilage complex foveal reattachment
    Waitayawinyu, Thanapong
    Sekekun, Narut
    Sopasilapa, Petai
    Boonyasirikool, Chinnakart
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (03) : 1707 - 1714
  • [7] Effectiveness of suture anchor and transosseous suture technique in arthroscopic foveal repair of the triangular fibrocartilage complex: a systematic review
    Ma, Hsuan-Hsiao
    Wang, Jung-Pan
    Yang, Chen-Yuan
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01)
  • [8] Biomechanical Comparison of Open and Arthroscopic Transosseous Repair of Triangular Fibrocartilage Complex Foveal Tears: A Cadaveric Study
    Ma, Ching-Hou
    Lin, Ting-Sheng
    Wu, Chin-Hsien
    Li, Dong-Yi
    Yang, Shih-Chieh
    Tu, Yuan-Kun
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (02): : 297 - 304
  • [9] Arthroscopic Treatment Results of Triangular Fibrocartilage Complex Tears in Adolescents: A Systematic Review
    Schachinger, Florian
    Farr, Sebastian
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (11)
  • [10] Relevant landmarks to navigate the suture locations for the arthroscopic triangular fibrocartilage complex foveal reattachment
    Thanapong Waitayawinyu
    Narut Sekekun
    Petai Sopasilapa
    Chinnakart Boonyasirikool
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 1707 - 1714