A study on structure improvement scheme of electromagnetic flow sensor for slurry flow measurement

被引:5
作者
Gao, Song [1 ]
Ma, Hao [1 ]
机构
[1] Henan Univ Sci & Technol, Coll Agr Equipment Engn, 263 Kaiyuan Ave, Luoyang 471023, Peoples R China
基金
中国国家自然科学基金;
关键词
electromagnetic flow sensor; slurry noise; calibration; measurement;
D O I
10.1177/00202940211064589
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A scheme to improve the structure of electromagnetic flow sensor is put forward in this paper, which can effectively solve the slurry noise problem when electromagnetic flowmeter measures slurry fluid. The electromagnetic flow sensor used for measuring slurry fluid has slurry noise interference in the measurement signal. At present, the method of increasing the excitation frequency of electromagnetic flow sensor is widely used to overcome slurry noise. However, high excitation frequency will lead to poor stability of zero point. In view of the shortcomings of existing methods, this paper studies the method of improving sensor structure to overcome slurry noise. Firstly, according to the mechanism of slurry noise, an improved scheme for the installation position of the measuring electrode of electromagnetic flow sensor is proposed, which can greatly reduce the probability of solid particles of slurry fluid colliding with the measuring electrode; Then, the relevant research results of bubble dynamics theory are applied to optimize the improvement scheme, and the improvement scheme is determined, through calibration, it is concluded that the improved sensor can reach the accuracy level of 1.0; Finally, through slurry measurement experiments, it is verified that the improved electromagnetic flow sensor can effectively overcome slurry noise.
引用
收藏
页码:519 / 534
页数:16
相关论文
共 39 条
[1]  
Cai W., 2004, Electromagnetic Flowmeter
[2]  
[程晨 Cheng Chen], 2019, [化工学报, CIESC Journal], V70, P4536
[3]   The effect of chemicals on the viscosity and stability of coal water slurries [J].
Dinçer, H ;
Boylu, F ;
Sirkeci, AA ;
Atesok, G .
INTERNATIONAL JOURNAL OF MINERAL PROCESSING, 2003, 70 (1-4) :41-51
[4]   Study on the length of pipe inlet section of pulp fluid based on CFD [J].
Gao, Song ;
Du, Xinwu ;
Jin, Shengjie ;
Liu, Qiaohong ;
Ma, Hao .
MEASUREMENT & CONTROL, 2020, 53 (9-10) :1709-1719
[5]   Study on measurement error of iron ore pipeline transportation flow based on weight function theory of electromagnetic flow sensor [J].
Gao, Song ;
Du, Xinwu ;
Yue, Jumei .
JOURNAL OF SUPERCOMPUTING, 2019, 75 (05) :2289-2303
[6]   Study on a New Electromagnetic Flow Measurement Technology Based on Differential Correlation Detection [J].
Ge, Liang ;
Chen, Junxian ;
Tian, Guiyun ;
Zeng, Wen ;
Huang, Qi ;
Hu, Ze .
SENSORS, 2020, 20 (09)
[7]   Electromagnetic Flow Detection Technology Based on Correlation Theory [J].
Ge, Liang ;
Li, Hailong ;
Huang, Qi ;
Tian, Guiyun ;
Wei, Guohui ;
Hu, Ze ;
Ahmed, Junaid .
IEEE ACCESS, 2020, 8 :56203-56213
[8]  
Ichiro W., 1990, ELECTROMAGNETIC FLOW, P97
[9]   Intelligent vibration detection and control system of agricultural machinery engine [J].
Jin Xin ;
Chen Kaikang ;
Ji Jiangtao ;
Zhao Kaixuan ;
Du Xinwu ;
Ma Hao .
MEASUREMENT, 2019, 145 :503-510
[10]  
Kobayashi, 1989, ELECTROMAGNETIC FLOW, P9