Measurement uncertainty evaluation and in-house method validation of the herbicide iodosulfuron-methyl-sodium in water samples by using HPLC analysis

被引:15
作者
Drolc, Andreja [1 ]
Pintar, Albin [1 ]
机构
[1] Natl Inst Chem, Lab Environm Sci & Engn, Ljubljana 1001, Slovenia
关键词
Photocatalytic degradation; HPLC; Iodosulfuron-methyl-sodium; Method validation; Measurement uncertainty;
D O I
10.1007/s00769-010-0712-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for separation and quantitative determination of the iodosulfuron-methyl-sodium in water samples by high-performance liquid chromatography (HPLC) was developed and in-house validated in order to demonstrate its performance for monitoring of heterogeneous photocatalytic elimination of the herbicide iodosulfuron-methyl-sodium from water. Surface and ground water samples were used to demonstrate its selectivity, detection and quantification limits, linearity, trueness and precision. In addition, stability of iodosulfuron-methylsodium was studied in function of temperature and time. Method accuracy was quantified through measurement uncertainty estimate based on method validation data. The paper gives practical and easy to follow guidance on how uncertainty estimates can be obtained from method validation experiments. It shows that, if properly planned and executed, key precision and trueness studies undertaken for validation purposes can also provide much of the data needed to produce an estimate of measurement uncertainty. Our analytical protocol allowed us to quantify iodosulfuron-methyl-sodium in ground water and surface water in concentration level between 2.50-50.0 mu mol L-1 with satisfactory recoveries (99-104%) and repeatability lower or equal than 0.3% for all the matrices. We also estimated within-laboratory reproducibility over 3-month period, which was 0.7%. We proved that the method was selective for determination of iodosulfuron-methyl-sodium in the relevant matrices. Measurement uncertainty of results was evaluated to be 4.0% with 95% confidence level. After validation and measurement uncertainty evaluation steps, results obtained showed that the method can be applied to efficiently monitor heterogenous photocatalytic degradation of the herbicide iodosulfuron-methyl-sodium.
引用
收藏
页码:21 / 29
页数:9
相关论文
共 21 条
[1]  
[Anonymous], FITN PURP AN METH
[2]  
[Anonymous], TOXICOL ENV CHEM
[3]  
[Anonymous], EURACHEM CITAC QUANT
[4]  
[Anonymous], PROTOCOL UNCERTAINTY
[5]  
[Anonymous], 1995, GUID EXPR UNC MEAS
[6]  
[Anonymous], PURE APPL CHEM
[7]  
[Anonymous], 200 BIPM IEC IFCC IL
[8]  
[Anonymous], 1990, 84661 ISO
[9]  
[Anonymous], 537 NORD
[10]  
[Anonymous], 2005, Standards methods for the examination of water and wastewater, V21