Environmental assessment of a building-integrated linear dielectric-based concentrating photovoltaic according to multiple life-cycle indicators

被引:35
作者
Lamnatou, Chr. [1 ]
Baig, H. [2 ]
Chemisana, D. [1 ]
Mallick, T. K. [2 ]
机构
[1] Univ Lleida, Dept Environm Sci, Appl Phys Sect, C Pere Cabrera S-N, Lleida 25001, Spain
[2] Univ Exeter, Environm & Sustainabil Inst, Penryn TR10 9FE, Cornwall, England
关键词
Life Cycle Assessment (LCA); Building-integrated concentrating PV (BICPV); ReCiPe; Eco-indicator 99 (EI99); Ecological footprint; USEtox; ENERGY; PERFORMANCE; SYSTEMS; GREEN; LCA;
D O I
10.1016/j.jclepro.2016.04.094
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Building-integrated concentrating photovoltaic (PV) systems are of great interest, offering several advantages for building and environment. The present study is an advancement towards the life cycle assessment (LCA) of a linear dielectric-based building-integrated concentrating PV system by means of multiple life-cycle impact assessment methods and environmental indicators (ReCiPe, Eco-indicator 99, ecological footprint, USEtox, ReCiPe-based and Eco-indicator-99-based payback times (PBT5), etc.), providing a detailed analysis. Two configurations (with and without reflective film) are examined, for different cities (Barcelona, Exeter and Dublin). By focussing on material manufacturing (system with reflective film), in general, ReCiPe (endpoint/single-score; points) results are in accordance to Ecoindicator 99 (single-score; points) findings and based on both methods PVs have the maximum contribution for ecosystems/ecosystem quality and human health. Moreover, based on USEtox results, there is a remarkable difference between the impact of the PVs and the impact of the other components. With regard to the PBT5, taking into account both configurations with/without reflective film, Barcelona presents the lowest ReCiPe and Eco-indicator-99 PBT5 ranging from 3.6 to 5.8 years. On the other hand, Exeter and Dublin show PBTs from 3.7 to 7.8 years. According to ReCiPe/endpoint results with characterization, for climate change/human health (system with reflective film) Barcelona shows 1.2 x 10(-7) disability adjusted -life-years per kWh while Dublin and Exeter present a footprint of present about 1.8 x 10(-7) disability-adjusted-life-years per kWh. Results in terms of (species.yr)/kWh are also presented (ReCiPe/endpoint with characterization), for several scenarios. Regarding the two configurations, the findings based on multiple approaches verify that reflective film considerably improves the eco-profile of the reference system (configuration without reflective film). For example, by utilizing reflective film there is a reduction of ReCiPe-based and Eco-indicator-99-based PBT5 ranging from 0.5 to 0.9 years, depending on the scenario. Finally, results from the literature are presented along with. results of the present study and a critical discussion is provided. Conclusively, the proposed LCA model can also be applied to similar systems, providing useful information about their environmental profile and offering the possibility to select among different configurations the best from ecological/cleaner production point of view. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:773 / 784
页数:12
相关论文
共 39 条
[1]   Energy viability of photovoltaic systems [J].
Alsema, EA ;
Nieuwlaar, E .
ENERGY POLICY, 2000, 28 (14) :999-1010
[2]  
[Anonymous], TRNSYS 16
[3]  
authors PRe various, 2014, SIMAPRO DAT MAN
[4]   Influence of spectrum and latitude on the annual optical performance of a dielectric based BICPV system [J].
Baig, Hasan ;
Fernandez, Eduardo F. ;
Mallick, Tapas K. .
SOLAR ENERGY, 2016, 124 :268-277
[5]   Performance modeling and testing of a Building Integrated Concentrating Photovoltaic (BICPV) system [J].
Baig, Hasan ;
Sellami, Nazmi ;
Mallick, Tapas K. .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2015, 134 :29-44
[6]   Enhancing performance of a linear dielectric based concentrating photovoltaic system using a reflective film along the edge [J].
Baig, Hasan ;
Sarmah, Nabin ;
Chemisana, Daniel ;
Rosell, Joan ;
Mallick, Tapas K. .
ENERGY, 2014, 73 :177-191
[7]   Sensitivity analysis to quantify uncertainty in Life Cycle Assessment: The case study of an Italian tile [J].
Cellura, Maurizio ;
Longo, Sonia ;
Mistretta, Marina .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (09) :4697-4705
[8]   Building Integrated Concentrating Photovoltaics: A review [J].
Chemisana, Daniel .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (01) :603-611
[9]   Life Cycle Assessment of a ground-mounted 1778 kWp photovoltaic plant and comparison with traditional energy production systems [J].
Desideri, Umberto ;
Proietti, Stefania ;
Zepparelli, Francesco ;
Sdringola, Paolo ;
Bini, Silvia .
APPLIED ENERGY, 2012, 97 :930-943
[10]   Multi-objective optimization minimizing cost and life cycle emissions of stand-alone PV-wind-diesel systems with batteries storage [J].
Dufo-Lopez, Rodolfo ;
Bernal-Agustin, Jose L. ;
Yusta-Loyo, Jose M. ;
Dominguez-Navarro, Jose A. ;
Ramirez-Rosado, Ignacio J. ;
Lujano, Juan ;
Aso, Ismael .
APPLIED ENERGY, 2011, 88 (11) :4033-4041