Energy and Exergy Analysis of a Subcritical Cascade Refrigeration System With Internal Heat Exchangers Using Environmentally Friendly Refrigerants

被引:14
作者
Aktemur, Cenker [1 ]
Ozturk, Ilhan Tekin [1 ]
机构
[1] Kocaeli Univ, Dept Mech Engn, Umuttepe Campus, TR-41380D Kocaeli, Turkey
来源
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME | 2021年 / 143卷 / 10期
关键词
cascade refrigeration system; internal heat exchanger; coefficient of performance; exergy efficiency; energy conversion; systems; energy systems analysis; THERMODYNAMIC PERFORMANCE; TEMPERATURE; ALTERNATIVES; MIXTURES;
D O I
10.1115/1.4049271
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study focuses on a thermodynamic performance analysis of a subcritical cascade refrigeration system (CRS) with internal heat exchangers (IHXs) using R41/R601, R41/R602A, and R41/cyclopentane as refrigerant pairs. The effect of evaporator temperature (T-ev), condenser temperature (T-cond), and temperature difference in the cascade heat exchanger (Delta T-CHX) on examined performance parameters are investigated. Each performance parameter is scrutinized by an optimum low-temperature circuit (LTC) condenser temperature. The operating parameters have some implications on the overall thermodynamic performance of the system. A change of 10 degrees C in the T-ev and T-cond affects the performance of the system by approximately +26% and -8%, respectively. Moreover, a variation of 1 degrees C in the Delta T-CHX reduces the performance of the system by about 2%. The effect of IHXs on the system has some interesting results. The coefficient of performance (COP) and exergy efficiency values of the system using R41/cyclopentane tend to constantly decrease by nearly 4.05%. Although not as much as R41/cyclopentane, there is also a slight drop in the performance of other refrigerant pairs. The discharge temperature in LTC and high-temperature circuit (HTC) compressors exceeds 120 degrees C for low-temperature refrigeration requirements, which is highly undesirable. Furthermore, the top priority components for the system improvement are HTC condenser, HTC compressor, and CHX. The refrigerant pairs with the thermodynamic performance from best to worst are R41/R601, R41/cyclopentane, and R41/R602A, respectively. Finally, the COP and exergy efficiency values of the modeled system are 10.40% higher and 3.06% lower, respectively, compared with current models in the literature.
引用
收藏
页数:13
相关论文
共 46 条
[1]  
Andersen SO., 1999, REPORT TEAP HFC PFC
[2]  
[Anonymous], 2006, CO2 SUPERMARKET REFR
[3]   Energy evaluation of R152a as drop in replacement for R134a in cascade refrigeration plants [J].
Cabello, R. ;
Sanchez, D. ;
Llopis, R. ;
Catalan, J. ;
Nebot-Andres, L. ;
Torrella, E. .
APPLIED THERMAL ENGINEERING, 2017, 110 :972-984
[4]  
Cengel Y. A., 2017, THERMODYNAMICS ENG A
[5]   Temperature characteristics of cascade refrigeration system by pressure adjustment [J].
Chung, HS ;
Jeong, HM ;
Kim, YG ;
Rahadiyan, L .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2005, 19 (12) :2303-2311
[6]  
Dikmen E, 2020, EL CEZERI FEN MUHEND, V7, P338
[7]   Theoretical analysis of a CO2-NH3 cascade refrigeration system for cooling applications at low temperatures [J].
Dopazo, J. Alberto ;
Fernandez-Seara, Jose ;
Sieres, Jaime ;
Uhia, Francisco J. .
APPLIED THERMAL ENGINEERING, 2009, 29 (8-9) :1577-1583
[8]   Exergetic analysis of the refrigeration system in ethylene and propylene production process [J].
Fabrega, F. M. ;
Rossi, J. S. ;
d'Angelo, J. V. H. .
ENERGY, 2010, 35 (03) :1224-1231
[9]  
Gami H.M., 2014, Int. J. Eng. Sci. Res. Technol., P6034
[10]   Advanced exergy analysis of a carbon dioxide ammonia cascade refrigeration system [J].
Gholamian, Ehsan ;
Hanafizadeh, Pedram ;
Ahmadi, Pouria .
APPLIED THERMAL ENGINEERING, 2018, 137 :689-699