Characterization of NIR interfaces for the feeding and in-line monitoring of a continuous granulation process

被引:15
|
作者
Roman-Ospino, Andres D. [1 ]
Tamrakar, Ashutosh [1 ]
Igne, Benoit [2 ]
Dimaso, Elyse Towns [2 ]
Airiau, Christian [2 ]
Clancy, Donald J. [2 ]
Pereira, Glinka [1 ]
Muzzio, Fernando J. [1 ]
Singh, Ravendra [1 ]
Ramachandran, Rohit [1 ]
机构
[1] Rutgers State Univ, Engn Res Ctr Struct Organ Particulate Syst C SOPS, Dept Chem & Biochem Engn, Piscataway, NJ 08854 USA
[2] GlaxoSmithKline GSK, Collegeville, PA 19426 USA
关键词
PAT; NIR; Chemometrics; PLS; Continuous; Manufacturing; NEAR-INFRARED SPECTROSCOPY; DRUG CONTENT; FRAME; FLOW; IMPLEMENTATION; STRATEGIES; PREDICTION; DESIGN; MODELS; BLENDS;
D O I
10.1016/j.ijpharm.2019.118848
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
This work describes the characterization of three NIR interfaces intended to monitor a continuous granulation process. Two interfaces (i.e. a barrel interface and a rotating paddle interface) were evaluated to monitor the API concentration at the entrance of the granulator, and a third interface (i.e. an outlet interface), was evaluated to examine the quality of the resulting outlet granules. The barrel interface provided an assessment of the API concentration during the feeding process by scanning the material conveyed by the screws of the loss-in-weight feeder. The rotating paddle interface analyzed discrete amounts of powder upon exiting the feeder via the accumulation of material on the paddles. Partial Least Squares (PLS) calibration models were developed using the same powder blends for the two inlet interfaces and using the outlet granules for the outlet interface. Five independent batches were used to evaluate the prediction performance of each inlet calibration model. The outlet interface produced the lowest error of prediction due to the homogeneity of the granules. The barrel interface produced lower errors of prediction than the rotating paddle interface. However, powder density affected only the barrel interface, producing deviations in the predicted values. Therefore, powder density is a factor that should be considered in the calibration sample design for spectroscopic measurements when using this type of interface. A variographic analysis demonstrated that the continuous 1-dimensional motion in the barrel and outlet interfaces produced representative measurements of each batch during calibration and test experiments, generating a low minimum practical error (MPE).
引用
收藏
页数:11
相关论文
共 50 条
  • [1] On-Line Monitoring of A Granulation Process By NIR Spectroscopy
    Alcala, Manel
    Blanco, Marcelo
    Bautista, Manel
    Gonzalez, Josep M.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2010, 99 (01) : 336 - 345
  • [2] In-line process monitoring on polymer melts by NIR-spectroscopy
    Fischer, D
    Bayer, T
    Eichhorn, KJ
    Otto, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (01): : 74 - 77
  • [3] IN-LINE FLUID BED GRANULATION MONITORING BY NIR SPECTROSCOPY. METHOD DEVELOPMENT AND VALIDATION
    Gavan, Alexandru
    Sylvester, Bianca
    Casian, Tibor
    Tomuta, Ioan
    FARMACIA, 2019, 67 (02) : 248 - 257
  • [4] In-line process monitoring on polymer melts by NIR-spectroscopy
    D. Fischer
    T. Bayer
    K.-J. Eichhorn
    M. Otto
    Fresenius' Journal of Analytical Chemistry, 1997, 359 : 74 - 77
  • [5] Monitoring an enzyme purification process using on-line and in-line NIR measurements
    Klimkiewicz, Anna
    Mortensen, Peter Paasch
    Zachariassen, Christian B.
    van den Berg, Frans W. J.
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2014, 132 : 30 - 38
  • [6] Fluidised bed granulation of two APIs: QbD approach and development of a NIR in-line monitoring method
    Gavan, Alexandru
    Iurian, Sonia
    Casian, Tibor
    Porfire, Alina
    Porav, Sebastian
    Voina, Ioana
    Oprea, Alexandru
    Tomuta, Ioan
    ASIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2020, 15 (04) : 506 - 517
  • [7] Fluidised bed granulation of two APIs:QbD approach and development of a NIR in-line monitoring method
    Alexandru Gauan
    Sonia Iurian
    Tibor Casian
    Alina Porfire
    Sebastian Porau
    Ioana Voina
    Alexandru Oprea
    Ioan Tomuta
    AsianJournalofPharmaceuticalSciences, 2020, 15 (04) : 506 - 517
  • [8] Process interfacing of in-line NIR spectrophotometers
    Mindel, BD
    PROCESS CONTROL AND QUALITY, 1997, 9 (04): : 173 - 178
  • [9] An agile and robust in-line NIR potency deviation detection method for monitoring and control of a continuous direct compression process
    Alam, Md Anik
    Liu, Yang Angela
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2021, 601
  • [10] Process monitoring and surface characterization with in-line XPS metrology
    Cabuil, N.
    Le Gouil, A.
    Doclot, O.
    Dickson, B.
    Lagha, A.
    Aminpur, M.
    Chaton, C.
    Royer, J-C.
    SOLID STATE TECHNOLOGY, 2007, 50 (10) : 48 - 51