A Pulsed Wave Doppler Ultrasound Blood Flowmeter by PMUTs

被引:23
作者
Ding, Hong [1 ,2 ]
Yang, Dengfei [1 ]
Qu, Mengjiao [1 ]
Yang, Chao [1 ]
Chen, Xuying [1 ,2 ]
Le, Xianhao [1 ]
Zhu, Ke [1 ]
Xu, Jinghui [3 ]
Lin, Liwei [2 ]
Xie, Jin [1 ]
机构
[1] Zhejiang Univ, State Key Lab Fluid Power & Mechatron Syst, Hangzhou 310027, Zhejiang, Peoples R China
[2] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
[3] MEMSound Pte Ltd, Singapore 823270, Singapore
基金
中国国家自然科学基金;
关键词
Doppler effect; Blood; Electron tubes; Ultrasonic imaging; Acoustics; Velocity measurement; Ultrasonic variables measurement; Piezoelectric micromachined ultrasonic transducer (pMUT); pulsed wave Doppler; blood flowmeter; FLOW; FLUID;
D O I
10.1109/JMEMS.2021.3103756
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This letter describes a blood flowmeter by the pulsed wave Doppler (PWD) ultrasound detection procedure utilizing piezoelectric micromachined ultrasonic transducers (pMUTs) with the aluminum nitride (AlN) film as the piezoelectric material. The transceiver electronics for the PWD scheme are constructed for system control and signal processing, and a blood-mimicking fluid (BMF) is synthesized for flow velocity tests. Both the average Doppler frequency-shift and Doppler power spectrum density (PSD) shift with respect to the flow velocity have been characterized and validated, and the flow direction can also be recognized. Finally, a real-time pulsatile flow measurement is demonstrated to emulate the feasibility of monitoring blood flows in practice. [2021-0077]
引用
收藏
页码:680 / 682
页数:3
相关论文
共 15 条
[1]  
Atkinson P., 1982, DOPPLER ULTRASOUND I
[2]  
Baker D. W, 1967, P 20 ANN C ENG MED B, V9
[3]   Physical, mathematical and numerical modelling of blood flow in cardiovascular disease [J].
Black, RA .
MEDICAL ENGINEERING & PHYSICS, 2006, 28 (01) :4-5
[4]   Atherosclerotic lesion size and vulnerability are determined by patterns of fluid shear stress [J].
Cheng, Caroline ;
Tempel, Dennie ;
van Haperen, Rien ;
van der Baan, Arjen ;
Grosveld, Frank ;
Daemen, Mat J. A. P. ;
Krams, Rob ;
de Crom, Rini .
CIRCULATION, 2006, 113 (23) :2744-2753
[5]  
Chien WC, 2016, 2016 INTERNATIONAL COMPUTER SYMPOSIUM (ICS), P415, DOI [10.1109/ICS.2016.89, 10.1109/ICS.2016.0090]
[6]   Quantitative regional cerebral blood flow MRI of animal model of attention-deficit/hyperactivity disorder [J].
Danker, Jared F. ;
Duong, Timothy Q. .
BRAIN RESEARCH, 2007, 1150 :217-224
[7]  
Ding H, 2020, PROC IEEE MICR ELECT, P400, DOI [10.1109/MEMS46641.2020.9056430, 10.1109/mems46641.2020.9056430]
[8]  
GILL R W, 1979, Ultrasound in Medicine and Biology, V5, P223, DOI 10.1016/0301-5629(79)90014-0
[9]  
Grossman W., 2006, GROSSMANS CARDIAC CA
[10]   Stretchable ultrasonic transducer arrays for three-dimensional imaging on complex surfaces [J].
Hu, Hongjie ;
Zhu, Xuan ;
Wang, Chonghe ;
Zhang, Lin ;
Li, Xiaoshi ;
Lee, Seunghyun ;
Huang, Zhenlong ;
Chen, Ruimin ;
Chen, Zeyu ;
Wang, Chunfeng ;
Gu, Yue ;
Chen, Yimu ;
Lei, Yusheng ;
Zhang, Tianjiao ;
Kim, NamHeon ;
Guo, Yuxuan ;
Teng, Yue ;
Zhou, Wenbo ;
Li, Yang ;
Nomoto, Akihiro ;
Sternini, Simone ;
Zhou, Qifa ;
Pharr, Matt ;
di Scalea, Francesco Lanza ;
Xu, Sheng .
SCIENCE ADVANCES, 2018, 4 (03)