COMPARISON OF SCLERAL FIXATION OF INTRAOCULAR LENS Sutureless Intrascleral Fixation Versus Conventional Sutured Scleral Fixation

被引:20
作者
Jang, Kyu Hwan [1 ]
Kong, Mingui [1 ,2 ]
Moon, Byung Gil [3 ]
Son, Gisung [1 ,2 ]
机构
[1] Hangil Eye Hosp, Dept Retinal Serv, Incheon, South Korea
[2] Catholic Kwandong Univ, Dept Ophthalmol, Coll Med, Incheon, South Korea
[3] Seoul Shinsegae Eye Ctr, Gyeonggi Do, South Korea
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2021年 / 41卷 / 04期
关键词
sutureless scleral fixation; sutured scleral fixation; intraocular lens; IMPLANTATION; IOL;
D O I
10.1097/IAE.0000000000002952
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the clinical outcomes of sutured scleral and sutureless intrascleral fixations of the intraocular lens. Methods: Medical records of patients who underwent sutureless intrascleral fixation (sutureless group) and the conventional sutured scleral fixation (sutured group) were retrospectively reviewed. Patient demographics and the clinical outcomes of the two techniques were compared before and 1, 3, and 6 months after surgery. Results: Seventy patients were followed up for 6 months after the surgery: 25 patients in the sutureless group (25 eyes) and 45 in the sutured group (45 eyes). Surgery time was shorter in the sutureless group than that in the sutured group (73.00 +/- 15.68 vs. 107.39 +/- 25.30 minutes, P < 0.001). The visual acuity gradually improved throughout the postoperative period in both groups, and a faster visual acuity recovery was observed in the sutureless group. The cylindrical error at 6 months after the surgery was significantly lower in the sutureless group than that in the sutured group (-1.33 +/- 0.55 vs. -2.29 +/- 1.19 diopter, P < 0.001). Conclusion: Sutureless intrascleral fixation is an effective and reliable surgical technique that provides more favorable visual and refractive outcomes than the conventional sutured scleral fixation method.
引用
收藏
页码:761 / 767
页数:7
相关论文
共 20 条
[1]   Sutureless scleral fixation of intraocular lenses: outcomes of two approaches. The 2014 Yasuo Tano Memorial Lecture [J].
Abbey, Ashkan M. ;
Hussain, Rehan M. ;
Shah, Ankoor R. ;
Faia, Lisa J. ;
Wolfe, Jeremy D. ;
Williams, George A. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (01) :1-5
[2]   Long-term results of scleral fixation of posterior chamber intralocular lenses in children [J].
Asadi, Reza ;
Kheirkhah, Ahmad .
OPHTHALMOLOGY, 2008, 115 (01) :67-72
[3]   Four-Flanged Intrascleral Intraocular Lens Fixation Technique: No Flaps, No Knots, No Glue [J].
Canabrava, Sergio ;
Lima, Ana Carolina Canedo Domingos ;
Ribeiro, Guilherme .
CORNEA, 2020, 39 (04) :527-528
[4]   Sutureless intrascleral fixation using different three-piece posterior chamber intraocular lenses: a literature review of surgical techniques in cases of insufficient capsular support and a retrospective multicentre study [J].
Czajka, Marcin Piotr ;
Frajdenberg, Agata ;
Stopa, Marcin ;
Pabin, Tomasz ;
Johansson, Bjorn ;
Jakobsson, Gunnar .
ACTA OPHTHALMOLOGICA, 2020, 98 (03) :224-236
[5]  
EMMRICH K, 1958, Dtsch Gesundheitsw, V13, P353
[6]   Iris-claw intraocular lens implantation: Efficiency and safety according to technique [J].
Hernandez Martinez, Adrian ;
Almeida Gonzalez, Carmen Victoria .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (10) :1186-1191
[7]   Flanged intraocular lens fixation via 27-gauge trocars using a double-needle technique decreases surgical wounds without losing its therapeutic effect [J].
Ishikawa, Hiroto ;
Fukuyama, Hisashi ;
Komuku, Yuki ;
Araki, Takashi ;
Gomi, Fumi .
ACTA OPHTHALMOLOGICA, 2020, 98 (04) :E499-E503
[8]   Outcomes of Using Sutureless, Scleral-Fixated Posterior Chamber Intraocular Lenses [J].
Kansal, Vinay ;
Onasanya, Oluwadara ;
Colleaux, Kevin ;
Rawlings, Nigel .
SEMINARS IN OPHTHALMOLOGY, 2019, 34 (7-8) :488-496
[9]   Implantation of scleral-fixated posterior chamber intraocular lenses in adults [J].
Kjeka, Ole ;
Bohnstedt, Jesper ;
Meberg, Kyrre ;
Seland, Johan H. .
ACTA OPHTHALMOLOGICA, 2008, 86 (05) :537-542
[10]   Use of 23-gauge or 25-gauge trocar cannula for globe maintenance in glued intraocular lens surgery [J].
Kumar, Dhivya Ashok ;
Agarwal, Amar ;
Jacob, Soosan ;
Prakash, Gaurav ;
Agarwal, Athiya .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04) :690-691