Characterization of hydroxyapatite films obtained by pulsed-laser deposition on Ti and Ti-6AL-4v substrates

被引:90
作者
Blind, O [1 ]
Klein, LH
Dailey, B
Jordan, L
机构
[1] Univ Paris 07, Fac Chirurg Dent, Paris, France
[2] Univ Paris 06, UMR 7045, Lab Physicochim Surfaces, Paris, France
[3] ENSCP, Lab Met Struct, F-75231 Paris, France
关键词
pulsed-laser deposition; hydroxyapatite; calcium phosphate coating; titanium; Ti-6Al-4V;
D O I
10.1016/j.dental.2004.12.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Pulsed-taser deposition (PLD) is a development process to obtain hydroxyapatite (HA) thin film. It is an alternative to hydroxyapatite deposition techniques usually employed to cover orthopaedic or dental titanium implant surfaces. The aim of this study is to find out the characteristic ratio for Ca/P (1.66) deposit on titanium implant with the PLD process. Methods. In a preliminary study, the coating parameters of pure and highly crystalline HA on Ti or Ti-6Al-4V substrates were verified by analysing the deposit by Rutherford backscattering spectroscopy (RBS). Ablation parameters to reach a stoichiometric hydroxyapatite composition (ideal Ca/P atomic ratio) and to control the growth of crystalline phases were: 575 degrees C for the substrate temperature, 0.4 mbar H2O vapour pressure in the ablation chamber, the target substrate distance was 40 mm and the deposition time was 120 min. In a second part, the film properties were analysed by means of XRD, SEM, AFM. The coating adhesion of the HA to the substrate was determined with a micro scratch tester. Results. The analysed HA thin films showed a perfect crystallized and textured deposit. Sample observation and surface quality analysis demonstrated a surface roughness and adhesion of the films to the substrates compatible with biological applications. Significance. These results suggest that pulsed-taser deposition is a suitable technique to obtain crystalline and adherent hydroxyapatite films on Ti or Ti-6Al-4V substrates. The quality of the HA deposit with the PLD process could be an interesting option for coating dental implant. (c) 2005 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1017 / 1024
页数:8
相关论文
共 22 条
[1]   Friction monitored scratch adhesion testing [J].
Bellido-Gonzailez, V. ;
Stefanopoulos, N. ;
Deguilhen, F. .
SURFACE & COATINGS TECHNOLOGY, 1995, 74-75 (1-3) :884-889
[2]  
Clèries L, 2000, J BIOMED MATER RES, V49, P43, DOI 10.1002/(SICI)1097-4636(200001)49:1<43::AID-JBM6>3.3.CO
[3]  
2-7
[4]   PULSED-LASER DEPOSITION AND PROCESSING OF BIOCOMPATIBLE HYDROXYLAPATITE THIN-FILMS [J].
COTELL, CM .
APPLIED SURFACE SCIENCE, 1993, 69 (1-4) :140-148
[5]   NOVEL MATERIALS APPLICATIONS OF PULSED LASER DEPOSITION [J].
COTELL, CM ;
GRABOWSKI, KS .
MRS BULLETIN, 1992, 17 (02) :44-53
[6]   STRUCTURAL-ANALYSIS OF HYDROXYAPATITE COATINGS ON TITANIUM [J].
DUCHEYNE, P ;
VANRAEMDONCK, W ;
HEUGHEBAERT, JC ;
HEUGHEBAERT, M .
BIOMATERIALS, 1986, 7 (02) :97-103
[7]   Deposition of hydroxyapatite thin films by excimer laser ablation [J].
Fernandez-Pradas, JM ;
Sardin, G ;
Cleries, L ;
Serra, P ;
Ferrater, C ;
Morenza, JL .
THIN SOLID FILMS, 1998, 317 (1-2) :393-396
[8]   Influence of thickness on the properties of hydroxyapatite coatings deposited by KrF laser ablation [J].
Fernández-Pradas, JM ;
Clèries, L ;
Martínez, E ;
Sardin, G ;
Esteve, J ;
Morenza, JL .
BIOMATERIALS, 2001, 22 (15) :2171-2175
[9]  
García F, 1998, J BIOMED MATER RES, V43, P69, DOI 10.1002/(SICI)1097-4636(199821)43:1<69::AID-JBM8>3.0.CO
[10]  
2-K