Covered self-expandable metal stents for pancreatic duct stricture: a systematic review and meta-analysis

被引:2
作者
Tringali, Alberto [1 ]
Costa, Deborah [1 ]
Rota, Matteo [2 ]
Adler, Douglas G. [3 ]
Costamagna, Guido [4 ]
机构
[1] ULSS 2 Marca Trevigiana, Conegliano Hosp, Dept Med, Endoscopy Unit, Conegliano, TV, Italy
[2] Univ Brescia, Dept Mol & Translat Med, Brescia, Italy
[3] Centura Hlth, Ctr Adv Therapeut Endoscopy CATE, Denver, CO USA
[4] Fdn Policlin Univ Agostino Gemelli IRCSS, Digest Endoscopy Unit, Rome, Italy
关键词
MULTIPLE PLASTIC STENTS; LONG-TERM OUTCOMES; PLACEMENT; MANAGEMENT; FEASIBILITY; EFFICACY;
D O I
10.1055/a-1880-7430
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims Placement of a covered (C)-self-expandable metal stent (SEMS) has been recently investigated as an alternative endoscopic treatment for main pancreatic duct stricture (MPDS) in chronic pancreatitis. Our aim was to carry out a systematic review and meta-analysis of studies quantifying efficacy and safety of C-SEMSs in the management of MPDS. Methods A multiple database search was performed, including MEDLINE, Embase and Cochrane Library, from January 2000 to September 2020, to identify studies reporting the efficacy and safety of C-SEMSs in patients with MPDS. Stricture and pain resolution were investigated. Other outcomes included technical success, stent migration, stricture recurrence and need for repeated stent placement. Pancreatitis, severe abdominal pain requiring stent removal and de-novo stricture were recorded as complications. Results Nineteen studies were identified, which included a total of 300 patients. C-SEMSs showed a pooled stricture resolution rate of 91 % [95 % confidence interval (CI), 85 %-96 %] and a pooled pain resolution rate of 92 % (95 % CI, 85 %-98 %). The pooled proportion for stricture recurrence was equal to 6 % (95 % CI, 1 %-14 %), while stent migration occurred in 33 of 300 patients, the pooled proportion being 7 % (95 % CI 1 %-15 %). The pooled mean stent duration was 133 days (95 % CI, 100-166 days). The most common complication was pancreatitis (3 %, 95 % CI 0 %-8 %), while de-novo stricture pooled proportion was 2 % (95 % CI, 0 %-5 %). Conclusions C-SEMSs are effective and safe in the treatment of MPDS. However, there is a significant need for further high-quality, well-designed studies to produce evidence-based data on short and long-term efficacy, safety, costs of C-SEMSs, and also optimal stent duration.
引用
收藏
页码:E1311 / E1321
页数:11
相关论文
共 50 条
[41]   Modified fully covered self-expandable metal stents with antimigration features for benign pancreatic-duct strictures in advanced chronic pancreatitis, with a focus on the safety profile and reducing migration [J].
Moon, Sung-Hoon ;
Kim, Myung-Hwan ;
Park, Do Hyun ;
Song, Tae Joon ;
Eum, Junbum ;
Lee, Sang Soo ;
Seo, Dong Wan ;
Lee, Sung Koo .
GASTROINTESTINAL ENDOSCOPY, 2010, 72 (01) :86-91
[42]   Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature [J].
van Halsema, Emo E. ;
Rauws, Erik A. J. ;
Fockens, Paul ;
van Hooft, Jeanin E. .
WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (43) :12468-12481
[43]   Endoscopic bilateral stenting of malignant hilar bile duct obstruction using novel partially covered self-expandable metal stents [J].
Yoo, S. S. ;
Jeong, S. ;
Lee, D. H. .
ENDOSCOPY, 2013, 45 :E328-E329
[44]   Elevated stricture rate following the use of fully covered self-expandable metal biliary stents for biliary leaks following liver transplantation [J].
Phillips, M. S. ;
Bonatti, H. ;
Sauer, B. G. ;
Smith, L. ;
Javaid, M. ;
Kahaleh, M. ;
Schmitt, T. .
ENDOSCOPY, 2011, 43 (06) :512-517
[45]   A tissue attached to self-expandable metal stents for biliary stricture could be useful to find malignancy [J].
Kwon, Hyungjun ;
Jung, Min Kyu ;
Park, Sung Jin ;
Heo, Jun ;
Lee, Dong Wook ;
Kang, Yoo Na ;
Han, Jaryung ;
Han, Young Seok ;
Lee, Won Kee .
SCIENTIFIC REPORTS, 2022, 12 (01)
[46]   Covered and Uncovered Self-Expandable Metallic Stents in the Treatment of Malignant Biliary Obstruction [J].
Qin, Wen-Yan ;
Li, Jing-Zhen ;
Peng, Wen-Ping ;
Zhang, Ming-Ming ;
Lao, Bo ;
Hong, Jie-Ming ;
Li, Lian-Biao .
IRANIAN RED CRESCENT MEDICAL JOURNAL, 2020, 22 (07)
[47]   Partially covered self-expandable metal stents versus polyethylene stents for malignant biliary obstruction: A cost-effectiveness analysis [J].
Barkun, Alan N. ;
Adam, Viviane ;
Martel, Myriam ;
AlNaamani, Khalid ;
Moses, Peter L. .
CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2015, 29 (07) :377-383
[48]   Plastic stents or covered self-expandable metal stents for benign biliary strictures: same song, different verse? [J].
Baron, Todd H. ;
Grimm, Ian S. .
HEPATOBILIARY SURGERY AND NUTRITION, 2016, 5 (06) :506-508
[49]   Removable and repositionable covered metal self-expandable stents for leaks after upper gastrointestinal surgery: experiences in a tertiary referral hospital [J].
Leenders, Bart J. M. ;
Stronkhorst, Arnold ;
Smulders, Frans J. ;
Nieuwenhuijzen, Grard A. ;
Gilissen, Lennard P. L. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2013, 27 (08) :2751-2759
[50]   Efficacy and safety of covered versus uncovered self-expandable metal stents for the palliative treatment of malignant distal biliary stricture: A long-term retrospective study [J].
Zhu, Liang ;
Wang, Zhenwen ;
Huang, Zhiquan ;
Yang, Xueping ;
Yu, Zhengping ;
Cao, Ronglai ;
Chen, Youxiang .
EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2023, 25 (06)