Comparative pullout behavior of half-hooked and commercial steel fibers embedded in UHPC under static and impact loads

被引:99
作者
Yoo, Doo-Yeol [1 ]
Kim, Soonho [1 ]
机构
[1] Hanyang Univ, Dept Architectural Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
基金
新加坡国家研究基金会;
关键词
Ultra-high-performance concrete; Steel fibers; Pullout resistance; Impact; Rate sensitivity; Dynamic increase factor; HIGH-PERFORMANCE CONCRETE; CEMENTITIOUS COMPOSITES; FLEXURAL BEHAVIOR; STRAIN-RATE; STRENGTH; TENSILE;
D O I
10.1016/j.cemconcomp.2018.12.023
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the pullout behaviors of various steel fibers embedded in ultra-high-performance concrete (UHPC) under static and impact loading conditions. For this purpose, four types of steel fibers, i.e., straight, hooked, twisted, and half-hooked, and three different loading rates applied by static and impact pullout test machines were adopted. To examine the effect of inclination angle on the pullout behavior, four different inclination angles of 0, 30, 45, and 60 were considered. Test results indicate that the highest average bond strengths were found for the hooked and twisted fibers for static and impact loads, respectively, whereas the straight fibers exhibited the lowest bond strength at all inclination angles. The effectiveness of using half-hooked fibers increased when they were inclined, and maximized at an inclination angle of 45 compared to straight and highly deformed fibers. The use of the twisted and half-hooked fibers was also more effective in static pullout energies than the hooked and straight fibers. The pullout resistance of all the steel fibers in UHPC was improved under impact loading conditions, and the order of the loading rate effectiveness regarding both the average bond strength and pullout energy was as follows: straight fibers > half-hooked fibers > twisted fibers > hooked fibers. The change in the failure mode from pullout to rupture, due to the increase in the loading rate, adversely affected the rate sensitivity of the bond strength and energy absorption capacity. Since the deformed steel fibers were easily ruptured under impact loads, their rupture failure needs to be prevented to achieve an excellent bond strength and energy absorption capacity.
引用
收藏
页码:89 / 106
页数:18
相关论文
共 38 条
  • [1] ACI Committee 239, 2012, ACI FALL CONVENTION
  • [2] AFGC, 2013, ULTR PERF FIBR REINF
  • [3] Bindiganavile V, 2001, ACI MATER J, V98, P10
  • [4] Hybrid effect of macro and micro steel fibers on the pullout and tensile behaviors of ultra-high-performance concrete
    Chun, Booki
    Yoo, Doo-Yeol
    [J]. COMPOSITES PART B-ENGINEERING, 2019, 162 : 344 - 360
  • [5] On the blast resistance of high performance tunnel segments
    Colombo, Matteo
    Martinelli, Paolo
    di Prisco, Marco
    [J]. MATERIALS AND STRUCTURES, 2016, 49 (1-2) : 117 - 131
  • [6] A design approach for tunnels exposed to blast and fire
    Colombo, Matteo
    Martinelli, Paolo
    di Prisco, Marco
    [J]. STRUCTURAL CONCRETE, 2015, 16 (02) : 262 - 272
  • [7] Farooq M., 2016, THESIS, P148
  • [8] Flanders L., 2016, 4 INT S ULTR PERF CO, P1
  • [9] Effects of Strain Rate on Tensile Behavior of Reactive Powder Concrete
    Fujikake, Kazunori
    Senga, Takanori
    Ueda, Nobuhito
    Ohno, Tomonori
    Katagiri, Makoto
    [J]. JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2006, 4 (01) : 79 - 84
  • [10] Gokoz U.N., 1981, International Journal of Cement Composites and Lighweight Concrete, V3, P187, DOI [10.1016/0262-5075(81)90051-8, DOI 10.1016/0262-5075(81)90051-8]