Design of a Magnetorheological Damper-Based Haptic Interface for Rehabilitation Applications

被引:3
作者
Asadi, E. [1 ]
Hoyle, A. [1 ]
Arzanpour, S. [1 ]
机构
[1] Simon Fraser Univ, Burnaby, BC V5A 1S6, Canada
关键词
haptic interface; rehabilitation; MR-damper; parallel manipulator resistive-map generation; simulation; UPPER-LIMB; STROKE; MODEL; ARM;
D O I
10.1177/1045389X11418863
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This article presents a novel haptic interface for rehabilitation purposes using MR-dampers. In the rehabilitation, patients are required to do certain exercises to train damaged muscles. Specialized devices are required to ensure patients will do the exercise accurately. Typical devices that are used for this application are difficult to program and may cause damage by applying excessive force to human body. The haptic device that is designed in this article will address the issues by employing MR-dampers and a user-friendly programming methodology. The concept of Resistive-Map generation is introduced as main strategy for activating MR-dampers and restricting the motion to the regions determined by the therapist. To simulate the performance of the system, an accurate model of MR-damper is obtained and validated experimentally. To test the performance of the proposed MR-based haptic device, the resistance-maps are first generated. MR-dampers are activated according to the positions of the MR-dampers in the resistance-map. The system is also simulated in MATLAB (R)/SimMechanics. The experimental and simulation results are in good agreement. The promising results of the proposed haptic interface make it a potential candidate for rehabilitation applications. Patients will be able to take the device home and the physiotherapists can online programme the exercises and monitor the performance of patients.
引用
收藏
页码:1269 / 1277
页数:9
相关论文
共 36 条
  • [1] The development of variably compliant haptic systems using magnetorheological fluids
    Ahmadkhanlou, F
    Washington, GN
    Wang, YR
    Bechtel, SE
    [J]. SMART STRUCTURES AND MATERIALS 2005: MODELING, SIGNAL PROCESSING, AND CONTROL, 2005, 5757 : 491 - 502
  • [2] The development of a five DOF magnetorheological fluid-based telerobotic haptic system
    Ahmadkhanlou, Farzad
    Washington, Gregory N.
    Bechtel, Stephen E.
    [J]. MODELING, SIGNAL PROCESSING, AND CONTROL FOR SMART STRUCTURES 2008, 2008, 6926
  • [3] Treatment interventions for the paretic upper limb of stroke survivors: A critical review
    Barreca, S
    Wolf, SL
    Fasoli, S
    Bohannon, R
    [J]. NEUROREHABILITATION AND NEURAL REPAIR, 2003, 17 (04) : 220 - 226
  • [4] Vibration control of an MR vehicle suspension system considering both hysteretic behavior and parameter variation
    Choi, Seung-Bok
    Seong, Min-Sang
    Ha, Sung-Hoon
    [J]. SMART MATERIALS AND STRUCTURES, 2009, 18 (12)
  • [5] Robotic techniques for upper limb evaluation and rehabilitation of stroke patients
    Colombo, R
    Pisano, F
    Micera, S
    Mazzone, A
    Delconte, C
    Carrozza, MC
    Dario, P
    Minuco, G
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2005, 13 (03) : 311 - 324
  • [6] DU WH, 2004, SENSOR REV, V24, P68
  • [7] DUNG LT, 2010, IEEE INT FOR STRAT T, P446
  • [8] Early and repetitive stimulation of the arm can substantially improve the long-term outcome after stroke: A 5-year follow-up study of a randomized trial
    Feys, H
    De Weerdt, W
    Verbeke, G
    Steck, GC
    Capiau, C
    Kiekens, C
    Dejaeger, E
    Van Hoydonck, G
    Vermeersch, G
    Cras, P
    [J]. STROKE, 2004, 35 (04) : 924 - 929
  • [9] Franchi D, 2010, LECT NOTES COMPUT SC, V6026, P141, DOI 10.1007/978-3-642-12712-0_13
  • [10] Nonlinear stiffness of a magneto-rheological damper
    Guo, DL
    Hu, HY
    [J]. NONLINEAR DYNAMICS, 2005, 40 (03) : 241 - 249