COMPARISON OF MACULAR THICKNESS MEASUREMENTS BETWEEN TIME-DOMAIN AND SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHIES IN EYES WITH AND WITHOUT MACULAR ABNORMALITIES

被引:12
作者
Giammaria, Daniele [1 ]
Ioni, Alfonso [1 ]
Bartoli, Beatrice [2 ]
Cofini, Vincenza [3 ]
Pellegrini, Giacomo [1 ]
Giannotti, Bruno [1 ]
机构
[1] Azienda Osped Osped Riuniti Marche Nord, Fano, Pesaro, Italy
[2] Univ Bologna, Fac Sci Stat, Bologna, Italy
[3] Univ Aquila, Internal Med & Publ Hlth Dept, I-67100 Laquila, Italy
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2011年 / 31卷 / 04期
关键词
agreement; comparison; Cirrus; macula; macular thickness; OCT; optical coherence tomography; repeatability; retina; Stratus; REPRODUCIBILITY; CIRRUS;
D O I
10.1097/IAE.0b013e3181eef401
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare Stratus time-domain optical coherence tomography (OCT) with Cirrus spectral-domain HD-OCT for measuring macular thickness in eyes with and without macular abnormalities. Methods: Seventy-five eyes of 48 patients were included in the study. Forty-one eyes of 29 patients had a normal macular thickness, and 34 eyes of 26 patients had an abnormal macular thickness. Macular scans were performed by 2 examiners (E1 and E2) with both OCTs. The agreement between the two OCT systems and interrater repeatability of each OCT system were determined using the Bland-Altman method. Results: Mean agreement between the 2 OCTs as 1.96 x standard deviation of the mean difference between the measurements of central macular subfield was 21 mu m in normal eyes and 36.8 mu m in abnormal eyes. In five macular subfields, the agreement was significantly better in normal eyes. Cirrus HD-OCT repeatability was significantly better than Stratus in five macular subfields in normal eyes and in six macular subfields in abnormal eyes. The repeatability was significantly better in normal eyes in five macular subfields for Stratus and in three macular subfields for Cirrus HD-OCT. Conclusion: The agreement between the two OCTs is low and varies in each macular subfield. Cirrus HD-OCT has shown a better repeatability than Stratus OCT, especially when measuring eyes with a thickened macula. RETINA 31: 707-716, 2011
引用
收藏
页码:707 / 716
页数:10
相关论文
共 11 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema [J].
Forooghian, Farzin ;
Cukras, Catherine ;
Meyerle, Catherine B. ;
Chew, Emily Y. ;
Wong, Wai T. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) :4290-4296
[3]   Comparison of time domain Stratus OCT and spectral domain SLO/OCT for assessment of macular thickness and volume [J].
Forte, R. ;
Cennamo, G. L. ;
Finelli, M. L. ;
de Crecchio, G. .
EYE, 2009, 23 (11) :2071-2078
[4]  
Kakinoki M, 2008, OPHTHAL SURG LAS IM, V39, pS37
[5]   Prospective Comparison of Cirrus and Stratus Optical Coherence Tomography for Quantifying Retinal Thickness [J].
Kiernan, Daniel F. ;
Hariprasad, Seenu M. ;
Chin, Eric K. ;
Kiernan, Claire L. ;
Rago, James ;
Mieler, William F. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (02) :267-275
[6]   Reproducibility of macular thickness and volume using zeiss optical coherence tomography in patients with diabetic macular edema [J].
Krzystolik, Magdalena G. ;
Strauber, Samara F. ;
Ai-ello, Lloyd Paul ;
Beek, Roy W. ;
Berger, Brian B. ;
Bressler, Neil M. ;
Browning, David J. ;
Chambers, Robert B. ;
Danis, Ronald P. ;
Davis, Matthew D. ;
Glassman, Adam R. ;
Gonzalez, Victor H. ;
Greenberg, Paul B. ;
Gross, Jeffrey G. ;
Kim, Judy E. ;
Kollman, Craig .
OPHTHALMOLOGY, 2007, 114 (08) :1520-1525
[7]   Macular thickness measurements in normal eyes using spectral domain optical coherence tomography [J].
Legarreta, John E. ;
Gregori, Giovanni ;
Punjabi, Omar S. ;
Knighton, Robert W. ;
Lalwani, Geeta A. ;
Puliafito, Carmen A. .
OPHTHALMIC SURGERY LASERS & IMAGING, 2008, 39 (04) :S43-S49
[8]   Comparison of Macular Thickness Measurements between Time Domain and Spectral Domain Optical Coherence Tomography [J].
Leung, Christopher Kai-shun ;
Cheung, Carol Yim-lui ;
Weinreb, Robert N. ;
Lee, Gary ;
Lin, Dusheng ;
Pang, Chi Pui ;
Lam, Dennis S. C. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (11) :4893-4897
[9]   Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT [J].
Paunescu, LA ;
Schuman, JS ;
Price, LL ;
Stark, PC ;
Beaton, S ;
Ishikawa, H ;
Wollstein, G ;
Fujimoto, JG .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (06) :1716-1724
[10]   Repeatability and reproducibility of fast macular thickness mapping with stratus optical coherence tomography [J].
Polito, A ;
Del Borrello, M ;
Isola, M ;
Zemella, N ;
Bandello, F .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (10) :1330-1337