Super Monte Carlo: A photon/electron dose calculation algorithm for radiotherapy

被引:2
作者
Keall, PJ [1 ]
Hoban, PW
West, MP
机构
[1] Liverpool Hosp, Canc Therapy Ctr, Sydney, NSW 2170, Australia
[2] Prince Wales Hosp, Dept Radiat Oncol, Sydney, NSW 2031, Australia
[3] Queensland Univ Technol, Ctr Med & Hlth Phys, Brisbane, Qld 4001, Australia
来源
RADIATION PHYSICS AND CHEMISTRY | 1998年 / 53卷 / 03期
关键词
D O I
10.1016/S0969-806X(98)00109-1
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Super-Monte Carlo (SMC) is a method of dose calculation for radiotherapy which combines both analytical calculations and Monte Carlo electron transport. Analytical calculations are used where possible, such as the determination of photon interaction density, to decrease computation time. A Monte Carlo method is used for the electron transport in order to obtain high accuracy of results. To further speed computation, Monte Carlo is used once only, to form an electron track kernel (etk). The etk is a dataset containing the lengths and energy deposition of each step of a number of electron tracks. The etk is transported from each incident particle interaction site, from which the dose is calculated. Dose distributions calculated in heterogeneous media show SMC results similar to those of Monte Carlo. For the same statistical uncertainty, SMC takes an order of magnitude less computation time than a full Monte Carlo simulation. SMC has only been implemented for photons and electrons, however the same basic method could be used for the transport of other particles. Current development includes the optimisation of the etks and the code in order to decrease computation time, and also the inclusion of SMC onto a clinical planning system. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:275 / 281
页数:7
相关论文
共 42 条
[1]   COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[2]   CALCULATION AND APPLICATION OF POINT SPREAD FUNCTIONS FOR TREATMENT PLANNING WITH HIGH-ENERGY PHOTON BEAMS [J].
AHNESJO, A ;
ANDREO, P ;
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (01) :49-56
[3]  
AHNESJO A, 1997, CHALLENGES CONFORMAL
[4]   3D DOSE CALCULATIONS FOR ELECTRON AND PHOTON BEAMS [J].
ALTSCHULER, MD ;
BLOCH, P ;
BUHLE, EL ;
AYYALASOMAYAJULA, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (02) :391-411
[5]   A UNIFIED ELECTRON PHOTON DOSIMETRY APPROACH [J].
BLOCH, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (03) :373-377
[6]   X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS [J].
BORTFELD, TR ;
KAHLER, DL ;
WALDRON, TJ ;
BOYER, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :723-730
[7]   A PHOTON DOSE DISTRIBUTION MODEL EMPLOYING CONVOLUTION CALCULATIONS [J].
BOYER, A ;
MOK, E .
MEDICAL PHYSICS, 1985, 12 (02) :169-177
[8]  
Brahme A., 1996, Australasian Physical and Engineering Sciences in Medicine, V19, P53
[9]   THE GENERATION OF INTENSITY-MODULATED FIELDS FOR CONFORMAL RADIOTHERAPY BY DYNAMIC COLLIMATION [J].
CONVERY, DJ ;
ROSENBLOOM, ME .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (06) :1359-1374
[10]  
Ebert M. A., 1997, Australasian Physical and Engineering Sciences in Medicine, V20, P164